HEMODYNAMIC-EFFECTS OF NASAL AND FACE MASK CONTINUOUS POSITIVE AIRWAY PRESSURE

被引:36
|
作者
MONTNER, PK
GREENE, ER
MURATA, GH
STARK, DM
TIMMS, M
CHICK, TW
机构
[1] UNIV NEW MEXICO,ALBUQUERQUE,NM 87131
[2] ALBUQUERQUE VET AFFAIRS MED CTR,ALBUQUERQUE,NM
[3] NEW MEXICO HIGHLANDS UNIV,LAS VEGAS,NM
关键词
D O I
10.1164/ajrccm.149.6.8004320
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Studies of the hemodynamic effects of nasal continuous positive airway pressure (n-CPAP) in normal subjects have had conflicting results. The largest study (n = 19) found no effect of up to 15 cm H2O on heart rate (HR), cardiac stroke volume (SV), or cardiac index. We hypothesized that n-CPAP, by increasing intrathoracic pressure, should decrease SV and cardiac output (CO) in a dose-dependent fashion in normal subjects. We also hypothesized that mouth position, i.e., open or closed, could affect intrathoracic pressure and thus SV and CO. Six normal subjects were tested with four levels of CPAP (5, 10, 15, and 20 cm H2O) under three mask conditions-face mask and nasal mask with the mouth open (mo) or with the mouth closed (mc). Noninvasive pulsed Doppler measurements of SV and HR were made under each condition. N-CPAP (mc) and face mask CPAP (f-CPAP) resulted in significant dose-dependent decreases of SV-24 +/- 5 ml (21%) and 33 +/- 5 ml (28%), respectively-from baseline to 20 cm H2O (p < 0.05). HR were unchanged and CO significantly decreased with n-CPAP(mc) and with f-CPAP, 1.6 +/- 0.38 L/min (23%) and 2.29 +/- 0.54 L/min (31%), respectively, from baseline to 20 cm H2O (p < 0.05). Esophageal pressure measurements verified increasing intrathoracic pressure with increasing levels of f-CPAP and n-CPAP (mc) but not with n-CPAP (mo). In conclusion, n-CPAP (mc) and f-CPAP resulted in significant and similar dose-dependent decreases in SV and CO.
引用
收藏
页码:1614 / 1618
页数:5
相关论文
共 50 条
  • [31] MEAN AIRWAY PRESSURE AND HEMODYNAMIC-EFFECTS - REPLY
    MUNEYUKI, M
    KONISHI, K
    ANESTHESIOLOGY, 1984, 60 (01) : 75 - 75
  • [32] Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial
    Jun Oto
    Qian Li
    William R Kimball
    Jingping Wang
    Abdolnabi S Sabouri
    Priscilla G Harrell
    Robert M Kacmarek
    Yandong Jiang
    Critical Care, 17
  • [33] Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial
    Oto, Jun
    Li, Qian
    Kimball, William R.
    Wang, Jingping
    Sabouri, Abdolnabi S.
    Harrell, Priscilla G.
    Kacmarek, Robert M.
    Jiang, Yandong
    CRITICAL CARE, 2013, 17 (06):
  • [34] ADMINISTRATION OF CONTINUOUS POSITIVE AIRWAY PRESSURE BY MASK
    STOCK, MC
    DOWNS, JB
    ACUTE CARE, 1984, 10 (3-4) : 184 - 188
  • [35] MASK CONTINUOUS POSITIVE AIRWAY PRESSURE IN AIDS
    DEVITA, MA
    FRIEDMAN, Y
    PETRELLA, V
    CRITICAL CARE CLINICS, 1993, 9 (01) : 137 - 151
  • [36] CONTINUOUS POSITIVE AIRWAY PRESSURE USING NASAL MASK IN RESPIRATORY-DISTRESS SYNDROME
    PORKSEN, C
    MONATSSCHRIFT KINDERHEILKUNDE, 1975, 123 (05) : 461 - 463
  • [37] COMPARISON OF MASK AND NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE AFTER EXTUBATION AND MECHANICAL VENTILATION
    PUTENSEN, C
    HORMANN, C
    BAUM, M
    LINGNAU, W
    CRITICAL CARE MEDICINE, 1993, 21 (03) : 357 - 362
  • [38] Randomized Trial of Prongs or Mask for Nasal Continuous Positive Airway Pressure in Preterm Infants
    Kieran, Emily A.
    Twomey, Anne R.
    Molloy, Eleanor J.
    Murphy, John F. A.
    O'Donnell, Colm P. F.
    PEDIATRICS, 2012, 130 (05) : E1170 - E1176
  • [39] HEMODYNAMIC-EFFECTS OF SHORT-TERM NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE THERAPY IN SLEEP-APNEA SYNDROME - MONITORING BY A FINGER ARTERIAL-PRESSURE DEVICE
    SFORZA, E
    CAPECCHI, V
    LUGARESI, E
    EUROPEAN RESPIRATORY JOURNAL, 1992, 5 (07) : 858 - 863
  • [40] CONTINUOUS POSITIVE AIRWAY PRESSURE BY FACE MASK IN ACUTE CARDIOGENIC PULMONARY-EDEMA
    RASANEN, J
    HEIKKILA, J
    DOWNS, J
    NIKKI, P
    VAISANEN, I
    VIITANEN, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (04): : 296 - 300