NONINVASIVE MONITORING OF CARDIAC-OUTPUT CHANGES DURING AORTIC CROSS-CLAMPING FOR INFRARENAL RECONSTRUCTION - A NEW TECHNIQUE USING SUPRASTERNAL DOPPLER-DERIVED CARDIAC-OUTPUT

被引:1
|
作者
DAVIES, JN
RANABOLDO, CJ
NEVIN, M
NORMAN, J
CROSSE, MM
WEBSTER, JHH
CHANT, ADB
机构
[1] Royal South Hampshire Hospital, Southampton, S09 4PE, Brintons Terrace
来源
关键词
CARDIAC OUTPUT; DOPPLER; PATIENT MONITORING; NONINVASIVE;
D O I
10.1016/S0950-821X(05)80618-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is a significant morbidity and mortality associated with elective infrarenal aortic reconstruction. To examine the value of continuous cardiac output monitoring for predicting those at risk, 40 consecutive patients were monitored using Doppler-derived cardiac output. The anaesthetist was blind to all information from the monitor and managed the patients using standard techniques. In 28 patients there were no observed changes, while in seven, cardiac output rose after aortic cross-clamping. In five patients a fall in cardiac output occurred after cross-clamping. No cardiac events or cardiac deaths occurred in the 35 patients who showed a rise or no change in cardiac output. However, there were three cardiac events, including one cardiac death in the group of five patients in whom a fall in cardiac output was observed. It would appear that intraoperative non-invasive Doppler-derived cardiac output monitoring successfully predicts high-risk patients who would perhaps benefit from more intensive pre-, peri- and postoperative care.
引用
收藏
页码:467 / 470
页数:4
相关论文
共 50 条
  • [32] NONINVASIVE DETERMINATION OF CARDIAC-OUTPUT IN PATIENTS WITH MITRAL-STENOSIS USING ECHOCARDIOGRAPHIC AND DOPPLER DATA
    ANGELI, SJ
    HAFT, JI
    JOURNAL OF CARDIOVASCULAR ULTRASONOGRAPHY, 1987, 6 (04): : 323 - 329
  • [33] NONINVASIVE DETERMINATION OF CARDIAC-OUTPUT IN PATIENTS WITH MITRAL-STENOSIS USING ECHOCARDIOGRAPHIC AND DOPPLER DATA
    ANGELI, SJ
    HAFT, JI
    CLINICAL RESEARCH, 1986, 34 (03): : A853 - A853
  • [34] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT USING PULSED-DOPPLER IN CRITICALLY ILL INFANTS AND CHILDREN
    TIBBALLS, J
    MERCIER, JC
    TRANG, TTH
    HARTMANN, JF
    LESCOEURBERG, B
    BEAUFILS, F
    INTENSIVE CARE MEDICINE, 1987, 13 (06) : 439 - 439
  • [35] MODE OF DELIVERY, PLASMA-CATECHOLAMINES AND DOPPLER-DERIVED CARDIAC-OUTPUT IN HEALTHY TERM NEWBORN-INFANTS
    HIRSIMAKI, H
    KERO, P
    EKBLAD, H
    SCHEININ, M
    SARASTE, M
    ERKKOLA, R
    BIOLOGY OF THE NEONATE, 1992, 61 (05): : 285 - 293
  • [36] DOPPLER-DERIVED CARDIAC-OUTPUT IN HEALTHY NEWBORN-INFANTS IN RELATION TO PHYSIOLOGICAL PATENCY OF THE DUCTUS-ARTERIOSUS
    HIRSIMAKI, H
    KERO, P
    WANNE, O
    ERKKOLA, R
    MAKOI, Z
    PEDIATRIC CARDIOLOGY, 1988, 9 (02) : 79 - 83
  • [37] Monitoring the Variation in Myocardial Function With the Doppler-Derived Myocardial Performance Index During Aortic Cross-Clamping
    Matyal, Robina
    Hess, Philip E.
    Asopa, Amit
    Zhao, Xiaoqin
    Panzica, Peter J.
    Mahmood, Feroze
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (02) : 204 - 208
  • [38] A NEW APPROACH TO THE NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT USING AN ANNULAR ARRAY DOPPLER TECHNIQUE .1. THEORETICAL CONSIDERATIONS AND ULTRASONIC FIELDS
    EVANS, JM
    SKIDMORE, R
    LUCKMAN, NP
    WELLS, PNT
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (03): : 169 - 178
  • [39] MONITORING OF CHANGES IN CARDIAC-OUTPUT BY TRANS-CUTANEOUS AORTOVELOGRAPHY, A NON-INVASIVE DOPPLER TECHNIQUE - COMPARISON WITH THERMODILUTION
    DISTANTE, A
    MOSCARELLI, E
    ROVAI, D
    LABBATE, A
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1980, 24 (3-4): : 171 - 175
  • [40] NONINVASIVE MONITORING OF CARDIAC-OUTPUT BY DOPPLER-ECHOCARDIOGRAPHY IN PATIENTS TREATED WITH VOLUME EXPANSION AFTER SUBARACHNOID HEMORRHAGE
    MAYER, SA
    SHERMAN, D
    FINK, ME
    HOMMA, S
    SOLOMON, RA
    LENNIHAN, L
    BECKFORD, A
    KLEBANOFF, LM
    CRITICAL CARE MEDICINE, 1995, 23 (09) : 1470 - 1474