PHENYLKETONURIA SCREENING WITH A FLUOROMETRIC MICROPLATE ASSAY

被引:0
|
作者
LUBENOW, N [1 ]
DIEPENBROCK, F [1 ]
SCHICKLING, H [1 ]
BOCK, D [1 ]
HECKLER, R [1 ]
SANDER, J [1 ]
机构
[1] STAATLICHES MED UNTERSUCHUNGSAMT HANNOVER,ROESEBECKSTR 4-6,D-30449 HANNOVER,GERMANY
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A fluorometric assay in microtitre plates for the screening of phenylketonuria was evaluated and adapted to a neonatal screening programme. Using this assay, it is possible to determine quantitatively the phenylalanine concentration in dried blood spots on filter paper. The test exhibited a linear calibration curve with a good slope as well as sufficient precision and accuracy in the statistical analysis. Interference by other amino acids and antibiotics was not observed. Only elevated concentrations of leucine interfered to a small degree. The phenylalanine concentration in dried blood spots of 13 phenylketonuria patients correlated to that in serum. 7381 dried blood samples of newborn infants were tested simultaneously by both the fluorometric and the Guthrie test. The results did not show significant differences. We screened 29182 newborns using the fluorometric assay and an online data processing programme. The internal repetition rate was 0.64%, the external recall rate 0.15%. False negative results were not observed. In December 1991 the fluorometric method replaced the Guthrie test in our routine programme for phenylketonuria screening, and was introduced as a follow up test for phenylketonuria patients.
引用
收藏
页码:525 / 528
页数:4
相关论文
共 50 条
  • [1] FLUOROMETRIC METHOD FOR PHENYLALANINE MICROPLATE ASSAY ADAPTED FOR PHENYLKETONURIA SCREENING
    GERASIMOVA, NS
    STEKLOVA, IV
    TUUMINEN, T
    CLINICAL CHEMISTRY, 1989, 35 (10) : 2112 - 2115
  • [3] A RAPID MICROPLATE-BASED FLUOROMETRIC ASSAY FOR PHAGOCYTOSIS
    UFF, CR
    POCKLEY, AG
    PHILLIPS, RKS
    IMMUNOLOGICAL INVESTIGATIONS, 1993, 22 (6-7) : 407 - 413
  • [4] MICROASSAY FOR SCREENING NEWBORNS FOR GALACTOSEMIA WITH USE OF A FLUOROMETRIC MICROPLATE READER
    YAMAGUCHI, A
    FUKUSHI, M
    MIZUSHIMA, Y
    SHIMIZU, Y
    TAKASUGI, N
    ARASHIMA, S
    OHYANAGI, K
    CLINICAL CHEMISTRY, 1989, 35 (09) : 1962 - 1964
  • [5] Screening for modulators of aggregation with a microplate elongation assay
    Berthelier, Valerie
    Wetzel, Ronald
    AMYLOID, PRIONS, AND OTHER PROTEIN AGGREGATES, PT C, 2006, 413 : 313 - 325
  • [6] Developing a fluorometric urease activity microplate assay suitable for automated microbioreactor experiments
    Lapierre, Frederic M.
    Bolz, Isabel
    Buechs, Jochen
    Huber, Robert
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [7] Application of a fluorometric microplate algal toxicity assay for riverine periphytic algal species
    Nagai, Takashi
    Taya, Kiyoshi
    Annoh, Hirochica
    Ishihara, Satoru
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2013, 94 : 37 - 44
  • [8] PHENYLKETONURIA, AND GUTHRIE INHIBITION ASSAY SCREENING PROCEDURE
    KRETCHMER, N
    MONTGOME.TA
    STEINKAMP, R
    DAY, RW
    BUTLER, AM
    HORNBERGER, R
    GREENBERG, RE
    POOLE, BD
    WRIGHT, SW
    LEVINE, SZ
    GAFFEY, W
    MCKHANN, GM
    KLEINMAN, D
    MOONEY, HW
    KNUDSON, A
    KOCH, R
    PEDIATRICS, 1963, 32 (03) : 344 - &
  • [9] 15-YEAR EXPERIENCE WITH SCREENING FOR PHENYLKETONURIA WITH AN AUTOMATED FLUOROMETRIC METHOD
    KIRKMAN, HN
    CARROLL, CL
    MOORE, EG
    MATHESON, MS
    AMERICAN JOURNAL OF HUMAN GENETICS, 1982, 34 (05) : 743 - 752
  • [10] Cuban neonatal screening of phenylketonuria using an ultramicro-fluorometric test
    Gonzalez, Ernesto Carlos
    Frometa, Amarilys
    del Rio, Lesley
    Castells, Elisa
    Robaina, Martha S.
    Garcia, Susana M.
    Licourt, Tania
    Arteaga, Ana L.
    Martinez, Laritza
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 129 - 132