CONTINUOUS MONITORING OF RESPIRATORY ACTIVITY AND BLOOD-PRESSURE

被引:0
|
作者
MAYER, J
HERRESMAYER, B
WEICHLER, U
PENZEL, T
PETER, JH
VONWICHERT, P
机构
来源
MEDIZINISCHE WELT | 1991年 / 42卷 / 06期
关键词
AMBULATORY BLOOD PRESSURE MONITORING; ABPM; ARTERIAL HYPERTENSION; SLEEP RELATED BREATHING DISORDERS; SLEEP APNEA;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sleep related breathing disorders occur frequently than expected in the past. Sleep apnea (SA) alone has a prevalence of 10% in the adult male population. Epidemiological and clinical studies indicate that SA and arterial hypertension are often associated. For the investigation of this interdependence, which is widely not understood, we have developed a portable long-term monitoring device, which can be applied to outpatients or can be integrated in a sleep laboratory. The device stores the nocturnal breathing pattern and invasive blood pressure (BP) via a catheter in the brachial artery. Due to extensive detection and evaluation procedures the unit can be used for scientific research primarily. With recent studies we have shown, that SA decreases the physiological BP fall during the night. We have provided further evidence, that anti-hypertensive therapy with beta-blockers and ACE-inhibitors have a different effect, especially on noctural BP vehaviour. As opposed to other measuring methods, this new system allows very accurate and long-term measurement of breathing pattern and BP behaviour, Last but not least, it does not disturb sleep.
引用
收藏
页码:472 / 474
页数:3
相关论文
共 50 条
  • [11] CAN SIMULTANEOUS AMBULATORY BLOOD-PRESSURE AND ACTIVITY MONITORING IMPROVE THE DEFINITION OF BLOOD-PRESSURE
    STEWART, MJ
    BROWN, H
    PADFIELD, PL
    AMERICAN JOURNAL OF HYPERTENSION, 1993, 6 (06) : S174 - S178
  • [12] AMBULATORY BLOOD-PRESSURE MONITORING AND BLOOD-PRESSURE REACTIVITY
    HARSHFIELD, GA
    PICKERING, TG
    PSYCHOPHYSIOLOGY, 1986, 23 (04) : 422 - 423
  • [13] MONITORING BLOOD-PRESSURE
    不详
    LANCET, 1979, 2 (8155): : 1279 - 1280
  • [14] BLOOD-PRESSURE MONITORING
    CARROLL, GC
    CRITICAL CARE CLINICS, 1988, 4 (03) : 411 - 434
  • [15] CURRENT ROLE OF AMBULATORY CONTINUOUS BLOOD-PRESSURE MONITORING (ABPM)
    HUNYOR, SN
    ROFFE, DJ
    KEWAL, N
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1986, 16 (04): : 554 - 554
  • [16] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MONITORING BY THE UNLOADING OF VASCULAR WALL
    WANG, MH
    CHEUNG, PW
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1417 - 1418
  • [17] CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITORING IN PATIENTS WITH SLEEP DISORDERS
    PENZEL, T
    MAYER, J
    PETER, JH
    PODSZUS, T
    VOIGT, KH
    VONWICHERT, P
    PHYSIOLOGICAL RESEARCH, 1992, 41 (01) : 11 - 17
  • [18] CONTINUOUS NEONATAL BLOOD-PRESSURE MONITORING VIA THE UMBILICAL ARTERY
    FEINAUER, LR
    GARDNER, RM
    PARKER, J
    CLINICAL RESEARCH, 1981, 29 (01): : A106 - A106
  • [19] CONTINUOUS NEONATAL BLOOD-PRESSURE MONITORING VIA THE UMBILICAL ARTERY
    FEINAUER, LR
    GARDNER, RM
    PARKER, J
    CLINICAL RESEARCH, 1982, 30 (01): : A142 - A142
  • [20] THE VALIDATION AND APPLICATION OF CONTINUOUS BLOOD-PRESSURE MONITORING IN PSYCHOPHYSIOLOGICAL RESEARCH
    LARKIN, KT
    LARKIN, KT
    CHRISTENFELD, N
    ALLEN, MT
    GAILLARD, A
    GROSSMAN, P
    PSYCHOPHYSIOLOGY, 1995, 32 : S8 - S9