PRELIMINARY-RESULTS IN THE CONSTRUCTION OF A 2D IMAGING DEVICE WITH METASTABLE SUPERCONDUCTING GRAINS

被引:5
|
作者
LIMAGNE, D [2 ]
JEUDY, V
HERES, O
GIRARD, TA
WAYSAND, G
机构
[1] UNIV LISBON,CTR FIS NUCL,P-1699 LISBON,PORTUGAL
[2] UNIV PARIS 06,CNRS,UA 17,PHYS SOLIDES GRP,F-75251 PARIS,FRANCE
关键词
D O I
10.1007/BF00693463
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have built and tested a 16 x 16 channel 2D matrix detector based on metastable superconducting grains. The camera was constructed from different thicknesses and size distributions of tin grains in paraffin, placed between two orthogonal planes of pickup coils and operated at 1.5 K. The homogeneity of the response curves of the 100 central pixels was better than 1.3%. Test objectives were provided by short range electron sources of S-35 and C-14, of varying geometries, placed in close proximity to the suspension. Each pixel was 700 x 700 mum2, and was separated from its nearest neighbour by 2000 microns. Preliminary images have been obtained without collimating optics or maskings, and an image reconstruction limited to analysis of the transition slopes of the nucleated grains. Analysis suggests a single pixel resolution. Prospects for the construction of a 3D tracking detector are considered.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 50 条
  • [21] EUROPEAN TESTING DEVICE CONTROL SERVICE OF CEPAC - EFFORTS AND PRELIMINARY-RESULTS
    FRANKE, W
    PAPIER, 1978, 32 (01): : 16 - 19
  • [22] MAGNETIC-RESONANCE-IMAGING OF THE BRAIN IN NEONATES - PRELIMINARY-RESULTS
    DUMOULIN, M
    LECOUFFE, P
    LEGRAND, M
    ROUSSEAU, J
    GREMILLET, C
    PRUVO, JP
    MARCHANDISE, X
    ANNALES DE PEDIATRIE, 1991, 38 (02): : 75 - 83
  • [23] MR-IMAGING IN THE EVALUATION OF SHIN SPLINTS - PRELIMINARY-RESULTS
    ANDERSON, MW
    UGALDE, V
    BATT, M
    GACAYAN, J
    SHELTON, DK
    RADIOLOGY, 1995, 197 : 297 - 297
  • [24] 2D IMAGING WITH A SINGLE-SIDED MPI DEVICE
    Graefe, K.
    von Gladiss, A.
    Bringout, G.
    Ahlborg, M.
    Buzug, T. M.
    2015 5TH INTERNATIONAL WORKSHOP ON MAGNETIC PARTICLE IMAGING (IWMPI), 2015, : O39 - O39
  • [25] NUCLEAR MAGNETIC-RESONANCE IMAGING IN DEMENTIAS, PRELIMINARY-RESULTS
    ERKINJUNTTI, T
    SIPPONEN, JT
    IIVANAINEN, M
    KETONEN, L
    SULKAVA, R
    SEPPONEN, RE
    ACTA NEUROLOGICA SCANDINAVICA, 1984, 69 : 30 - 31
  • [26] AN IMPROVED DEVICE FOR NEAR-BOTTOM WATER SAMPLING - PRELIMINARY-RESULTS
    BHAUD, M
    JOURNAL DU CONSEIL, 1983, 41 (01): : 46 - 49
  • [27] 2D relativistic MHD simulations of PWNe: Preliminary results
    Amato, E
    Del Zanna, L
    Bucciantini, N
    YOUNG NEUTRON STARS AND THEIR ENVIRONMENTS, 2004, (218): : 179 - 180
  • [28] PRELIMINARY-RESULTS OF A COMPARATIVE SEM STUDY OF QUARTZ GRAINS FROM PERIGLACIAL AND PERIDESERT LOESS
    COUDEGAUSSEN, G
    BALESCU, S
    CATENA, 1987, : 129 - 144
  • [29] ON THE ELECTROSTATIC POTENTIAL AND CHARGE OF COSMIC GRAINS .1. THEORETICAL BACKGROUND AND PRELIMINARY-RESULTS
    LAFON, JPJ
    LAMY, PL
    MILLET, J
    ASTRONOMY & ASTROPHYSICS, 1981, 95 (02) : 295 - 303
  • [30] MR IMAGING OF THE HANDS IN EARLY RHEUMATOID-ARTHRITIS - PRELIMINARY-RESULTS
    ROMINGER, MB
    BERNREUTER, WK
    KENNEY, PJ
    MORGAN, SL
    BLACKBURN, WD
    ALARCON, GS
    RADIOGRAPHICS, 1993, 13 (01) : 37 - 46