EXCIMER LASER ANGIOPLASTY IN THE ATHEROSCLEROTIC RABBIT - COMPARISON WITH BALLOON ANGIOPLASTY

被引:5
|
作者
ROSENFELDT, FL
CHI, L
BLACK, AJR
WAUGH, JR
PEDERSEN, JS
LEVATTER, J
机构
[1] ROYAL MELBOURNE HOSP, DEPT CARDIOL, PARKVILLE, VIC 3050, AUSTRALIA
[2] ALFRED HOSP, DEPT RADIOL, PRAHRAN, VIC 3181, AUSTRALIA
[3] ALFRED HOSP, DEPT PATHOL, PRAHRAN, VIC 3181, AUSTRALIA
[4] ACCULASE INC, SAN DIEGO, CA USA
基金
英国医学研究理事会;
关键词
D O I
10.1016/0002-8703(92)90597-O
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The early and late results of excimer laser angioplasty and balloon angioplasty were compared in atherosclerotic rabbit iliac arteries. Immediately after laser angioplasty (n = 13) with a bare 600-mu-m fiber, there was a 33% increase in angiographically measured minimum lumen diameter; after balloon angioplasty (n = 12), there was a 53% increase. Restenosis (defined as loss of at least 50% of the gain achieved by angioplasty) occurred in none of six laser-treated rabbits studied 1 month later, compared with four of six balloon-treated rabbits (p = 0.06). Planimetric measurements of cross sections of the arterial wall 1 month after angioplasty showed less intimal and medial tissue in laser-treated (1.8 +/- 0.2 mm2) than in the balloon-treated rabbits (3.0 +/- 0.4 mm2; p < 0.05). Typical thermal effects were absent on microscopic examination of laser angioplasty sites. It is concluded that in this animal model, excimer laser irradiation results in an immediate increase in lumen diameter comparable with balloon angioplasty, but is associated with less residual atheromatous tissue than balloon angioplasty and a trend toward a lower rate of restenosis.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [21] ANGIOGRAPHIC AND HISTOLOGIC CONSEQUENCES OF LASER THERMAL ANGIOPLASTY - COMPARISON WITH BALLOON ANGIOPLASTY
    SANBORN, TA
    HAUDENSCHILD, CC
    GARBER, GR
    RYAN, TJ
    FAXON, DP
    CIRCULATION, 1987, 75 (06) : 1281 - 1286
  • [22] EXCIMER LASER-FACILITATED BALLOON ANGIOPLASTY OF A NONDILATABLE LESION
    ISRAEL, DH
    MARMUR, JD
    SANBORN, TA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (04) : 1118 - 1119
  • [23] REDUCTION OF THROMBOGENICITY WITH ARGON-LASER ANGIOPLASTY - COMPARISON WITH BALLOON ANGIOPLASTY
    TOMARU, T
    UCHIDA, Y
    NAKAMURA, F
    YANAGISAWAMIWA, A
    FUJIMORI, Y
    GONZALEZ, JA
    KAMIJO, T
    SUGIMOTO, T
    JAPANESE HEART JOURNAL, 1993, 34 (01): : 79 - 90
  • [24] Reduced vasoreactivity and thrombogenicity with pulsed laser angioplasty: Comparison with balloon angioplasty
    Tomaru, T
    Nakamura, F
    YanagisawaMiwa, A
    Fujimori, Y
    Omata, M
    Kawai, S
    Okada, R
    Uchida, Y
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1995, 8 (06) : 643 - 651
  • [25] EXCIMER LASER CORONARY ANGIOPLASTY (ELCA) IN PATIENTS WITH RESTENOSIS AFTER PRIOR BALLOON ANGIOPLASTY (BA)
    REEDER, GS
    BRESNAHAN, JF
    BRESNAHAN, DR
    LITVACK, F
    CIRCULATION, 1990, 82 (04) : 672 - 672
  • [26] USEFULNESS OF A PROTOTYPE DIRECTIONAL CATHETER FOR EXCIMER-LASER CORONARY ANGIOPLASTY IN NARROWINGS UNFAVORABLE FOR CONVENTIONAL EXCIMER OR BALLOON ANGIOPLASTY
    RECHAVIA, E
    FEDERMAN, J
    SHEFER, A
    MACKO, G
    EIGLER, NL
    LITVACK, F
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (16): : 1144 - 1146
  • [27] ARE RESIDUAL STENOSES AFTER EXCIMER-LASER ANGIOPLASTY AND CORONARY ATHERECTOMY DUE TO INEFFICIENT OR SMALL DEVICES - COMPARISON WITH BALLOON ANGIOPLASTY
    SAFIAN, RD
    FREED, M
    LICHTENBERG, A
    MAY, MA
    JURAN, N
    GRINES, CL
    ONEILL, WW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (06) : 1628 - 1634
  • [28] BALLOON OVERSIZING REDUCES RESTENOSIS FOLLOWING ANGIOPLASTY IN ATHEROSCLEROTIC RABBIT MODEL
    LEVEEN, R
    FLOOD, B
    MOORE, B
    WOLF, G
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S18 - S18
  • [29] LASER BALLOON ANGIOPLASTY
    CHEONG, WF
    SPEARS, JR
    WELCH, AJ
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1991, 19 (2-3) : 113 - 146
  • [30] LASER RECANALIZATION, LASER ASSISTED BALLOON ANGIOPLASTY AND LASER ANGIOPLASTY
    MATSUMOTO, T
    RAJYAGURU, V
    OKAMURA, T