Measurement of a Blood Velocity by using Photoplethysmograph and Radial Artery Pulse Wave Equipped with Magnetic Hall Device

被引:4
|
作者
Jang, Deok-Hyeong [1 ]
Kim, Dam-Bee [2 ]
Choi, Suel-Gi [2 ]
Lee, Sang-Suk [2 ]
机构
[1] Mediana Co Ltd, Dongwha Med Instrument Complex,1650-1 Dongwha Ri, Wonju 220801, Gangwon Do, South Korea
[2] Sangji Univ, Dept Oriental Biomed Engn, Wonju 220702, Gangwon Do, South Korea
来源
JOURNAL OF THE KOREAN MAGNETICS SOCIETY | 2012年 / 22卷 / 04期
关键词
clip-type pulsimeter; permanent magnet; Hall device; radial artery pulse wave; PPG (photoplethysmograph); simultaneous measurement; blood velocity;
D O I
10.4283/JKMS.2012.22.4.130
中图分类号
O59 [应用物理学];
学科分类号
摘要
One prototype product of clip-type pulsimeter equipped with magnetic field sensing semiconductor Hall device after one permanent magnet attached " Chwan" position in center of a radial artery was developed. The clip-pulsimeter was composed of the hard ware system measuring to voltage signals. To measure the blood velocity, the radial artery pulsimeter is simultaneously connected the PPG (photoplethysmograph). Analysis and comparison of two pulse waves data has done obtained from a clinical test of forty subjects of 20 ages. The value of a blood velocity simultaneously measured from a radial artery puls wave and PPG is an average value of 0.8m/s. The usage of this research results is possible to store the biomedical signals for health care.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 50 条
  • [21] Using a phonocardiography in a pulse wave velocity measurement
    Jelinek, M
    Dobes, J
    Pousek, L
    Hána, K
    PROCEEDINGS OF THE 3RD IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY, 2003, : 491 - 493
  • [22] Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement
    Boese, JM
    Bock, M
    Schoenberg, SO
    Schad, LR
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06): : 1703 - 1713
  • [23] Pulse Wave Velocity Measurement in the Carotid Artery Using an LED-LED Array Pulse Oximeter
    Campbell, Jake D.
    Holder-Pearson, Lui
    Pretty, Christopher G.
    Bones, Phil
    Chase, J. Geoffrey
    IFAC PAPERSONLINE, 2020, 53 (02): : 16031 - 16036
  • [24] MEASUREMENT OF RETINAL ARTERY PULSE WAVE VELOCITY IN THE RAT USING HIGH SPEED IMAGING
    Golzan, S. M.
    Butlin, M.
    Kouchaki, Z.
    Avolio, A. P.
    Graham, S. L.
    HYPERTENSION, 2014, 63 (06) : E147 - E147
  • [25] Study of Pulse Wave Velocity Noninvasive Detecting Instrument Based on Radial Artery and Finger Photoplethysmography Pulse Wave
    Lin, Yang
    Song, Zhang
    Yang Yimin
    2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION WORKSHOP: IITA 2008 WORKSHOPS, PROCEEDINGS, 2008, : 705 - 708
  • [26] A Magnetic Plethysmograph Probe for Local Pulse Wave Velocity Measurement
    Nabeel, P. M.
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (05) : 1065 - 1076
  • [27] An Automatic Pulse Wave Velocity Estimation using a Blood Pressure Sensor for Invasive Measurement
    Choi, Junghyeon
    Park, Junho
    Cho, Jongman
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY, 2008, : 539 - 542
  • [28] Pulse wave velocity measurement; developing process of new measuring device
    Peter, Lukas
    Foltyn, Jan
    Cerny, Martin
    2015 IEEE 13TH INTERNATIONAL SYMPOSIUM ON APPLIED MACHINE INTELLIGENCE AND INFORMATICS (SAMI), 2015, : 59 - 62
  • [29] Automated and Accurate Measurement of Aortic Pulse Wave Velocity Using Magnetic Resonance Imaging
    Giri, S. S.
    Ding, Y.
    Nishijima, Y.
    Pedraza-Toseano, A.
    Burns, P. M.
    Hamlin, R. L.
    Simonetti, O. P.
    COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 : 661 - +
  • [30] A pulse wave velocity measurement system using USB
    Wu, Hsien-Tsai
    Lin, Chia-Hsin
    Chen, Hsuan-Kuang
    3RD INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATIONS AND CONTROL TECHNOLOGIES, VOL 3, PROCEEDINGS, 2005, : 85 - 90