MEASUREMENT OF TUMOR PH DURING MICROWAVE INDUCED EXPERIMENTAL AND CLINICAL HYPERTHERMIA WITH A FIBER OPTIC PH MEASUREMENT SYSTEM

被引:14
|
作者
VANDEMERWE, SA
VANDENBERG, AP
VANDERZEE, J
REINHOLD, HS
机构
[1] ERASMUS UNIV, DEPT EXPTL RADIOTHERAPY, 3000 DR ROTTERDAM, NETHERLANDS
[2] TNO, INST RADIOBIOL, RIJSWIJK, NETHERLANDS
关键词
Fiber optic; Hyperthermia; pH measurement; Tumor pH;
D O I
10.1016/0360-3016(90)90266-M
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The influence of hyperthermia on tissue pH was investigated using a modified version of the fiber optic monitoring system. This newly developed system was tested for use in tissues and found to be suitable for pH measurement during microwave induced hyperthermia. The fiber optic pH probe (0.7 mm diameter) could be easily used in the electromagnetic fields produced by the microwave applicators, whereas only the display unit required some shielding. Tissue pH of experimental and clinical tumors was measured concurrently with local microwave hyperthermia treatment. The mean initial intratumor pH of a rat rhabdomyosarcoma was 7.03 (SD 0.13, n = 19) and the pH of human subcutis was 7.45 (SD 0.02, n = 8). In rat tumor a primary pH decrease was observed during heating which was fully reversed during cooling. The coefficient of temperature dependence was -0.016 pH unit/°C (SD 0.004, n = 12). After approximately 1 hr of heating at 43°C a further pH decrease of 0.1-0.3 unit occurred which was not reversed directly after treatment. Measurements during clinical local microwave hyperthermia treatments after radiotherapy revealed similar changes in pH values, primary as well as secondary. The estimated coefficient of temperature dependence for the reversible pH change, which occurred in subcutis as well as in tumor tissue, was -0.016 pH unit/°C (SD 0.004, n = 12). The fiber optic pH measurement system is expected to be a valuable tool in the thorough investigation of temperature and time related pH changes in tumor during experimental as well as clinical hyperthermia treatment. © 1990.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [41] MEASUREMENT OF THE CHANGES IN PH IN PHOTOGRAPHIC COATINGS DURING DEVELOPMENT
    EGGERS, J
    PHOTOGRAPHIC SCIENCE AND ENGINEERING, 1960, 4 (05): : 284 - 287
  • [42] CONTINUOUS TISSUE PH MEASUREMENT ON FETUS DURING DELIVERY
    HENNER, H
    EHRSAM, A
    HALLER, U
    ARCHIV FUR GYNAKOLOGIE, 1978, 226 (1-2): : 129 - &
  • [43] Fiber optic sensor integration system and measurement technique
    Stinson-Bagby, KL
    Marcus, MA
    Fielder, RS
    INDUSTRIAL AND HIGHWAY SENSORS TECHNOLOGY, 2003, 5272 : 150 - 156
  • [44] Optic fiber interferometric system for absolute distance measurement
    Ye, SG
    Xiao, H
    Hong, HT
    Wang, CH
    SELF-CALIBRATED INTELLIGENT OPTICAL SENSORS AND SYSTEMS, 1996, 2594 : 202 - 207
  • [45] A Spectrophotometric System for High Precision Measurement of pH of Seawater
    Cao Lu
    Wang Xiao-Hong
    Zhang Yun-Yan
    Wang Zhao-Yu
    Chu Dong-Zhi
    Ma Ran
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (03) : 331 - 335
  • [46] IoT-based Programmable pH Measurement System
    Yang, Cheng-Huei
    Wu, Tsung-Che
    2022 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN, IEEE ICCE-TW 2022, 2022, : 341 - 342
  • [47] Optimization of the automated colorimetric measurement system for pH of liquid
    Katin, Oleg
    Lukyanov, Aleksander
    Goryanina, Ksenia
    XIII INTERNATIONAL SCIENTIFIC-TECHNICAL CONFERENCE DYNAMIC OF TECHNICAL SYSTEMS (DTS-2017), 2017, 132
  • [48] Voltammetry based handheld measurement system for soil pH
    Singh, Mukul
    Patkar, Rajul
    Vinchurkar, Madhuri
    Baghini, Maryam Shojaei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 885
  • [49] pH Measurement IoT System for Precision Agriculture Applications
    Archbold, G.
    Beltran, A.
    Ruiz, F.
    Narducci, M.
    Mendez, D.
    Trujillo, L.
    Parra, C.
    Carrillo, H.
    Mouazen, A.
    IEEE LATIN AMERICA TRANSACTIONS, 2019, 17 (05) : 823 - 832
  • [50] A radio transmission pH measurement system for continuous evaluation of fluid pH in the rumen of cows
    Sato, Shigeru
    Kimura, Atsushi
    Anan, Tomoaki
    Yamagishi, Norio
    Okada, Keiji
    Mizuguchi, Hitoshi
    Ito, Kazunori
    VETERINARY RESEARCH COMMUNICATIONS, 2012, 36 (01) : 85 - 89