MEASUREMENT OF TUMOR PH DURING MICROWAVE INDUCED EXPERIMENTAL AND CLINICAL HYPERTHERMIA WITH A FIBER OPTIC PH MEASUREMENT SYSTEM

被引:14
|
作者
VANDEMERWE, SA
VANDENBERG, AP
VANDERZEE, J
REINHOLD, HS
机构
[1] ERASMUS UNIV, DEPT EXPTL RADIOTHERAPY, 3000 DR ROTTERDAM, NETHERLANDS
[2] TNO, INST RADIOBIOL, RIJSWIJK, NETHERLANDS
关键词
Fiber optic; Hyperthermia; pH measurement; Tumor pH;
D O I
10.1016/0360-3016(90)90266-M
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The influence of hyperthermia on tissue pH was investigated using a modified version of the fiber optic monitoring system. This newly developed system was tested for use in tissues and found to be suitable for pH measurement during microwave induced hyperthermia. The fiber optic pH probe (0.7 mm diameter) could be easily used in the electromagnetic fields produced by the microwave applicators, whereas only the display unit required some shielding. Tissue pH of experimental and clinical tumors was measured concurrently with local microwave hyperthermia treatment. The mean initial intratumor pH of a rat rhabdomyosarcoma was 7.03 (SD 0.13, n = 19) and the pH of human subcutis was 7.45 (SD 0.02, n = 8). In rat tumor a primary pH decrease was observed during heating which was fully reversed during cooling. The coefficient of temperature dependence was -0.016 pH unit/°C (SD 0.004, n = 12). After approximately 1 hr of heating at 43°C a further pH decrease of 0.1-0.3 unit occurred which was not reversed directly after treatment. Measurements during clinical local microwave hyperthermia treatments after radiotherapy revealed similar changes in pH values, primary as well as secondary. The estimated coefficient of temperature dependence for the reversible pH change, which occurred in subcutis as well as in tumor tissue, was -0.016 pH unit/°C (SD 0.004, n = 12). The fiber optic pH measurement system is expected to be a valuable tool in the thorough investigation of temperature and time related pH changes in tumor during experimental as well as clinical hyperthermia treatment. © 1990.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [2] CONTINUOUS MEASUREMENT OF INTRAVASCULAR PH WITH A FIBER OPTIC SENSOR
    ABRAHAM, E
    MARKLE, DR
    FINK, S
    EHRLICH, H
    TSANG, M
    SMITH, M
    MEYER, A
    CRITICAL CARE MEDICINE, 1985, 13 (04) : 354 - 354
  • [3] A FIBER OPTIC CHEMICAL SENSOR FOR MEASUREMENT OF GROUNDWATER PH
    MAHER, MH
    SHAHRIARI, MR
    JOURNAL OF TESTING AND EVALUATION, 1993, 21 (05) : 448 - 452
  • [4] Fiber Optic sensor for simultaneous measurement of pH and dissolved oxygen
    Deepa, N.
    Ganesh, A. Balaji
    Advancements in Automation and Control Technologies, 2014, 573 : 842 - 847
  • [5] PH MEASUREMENT WITH A FIBER-OPTIC TISSUE-PH MONITOR AND A STANDARD BLOOD-PH METER
    SUIDAN, JS
    YOUNG, BK
    CLINICAL CHEMISTRY, 1983, 29 (08) : 1566 - 1566
  • [6] Intrinsic Fiber Optic pH Sensor for Measurement of pH Values in the Range of 0.5-6
    Thu Hien Nguyen
    Venugopalan, Thillainathan
    Sun, Tong
    Grattan, Kenneth T. V.
    IEEE SENSORS JOURNAL, 2016, 16 (04) : 881 - 887
  • [7] A novel fiber optic sensor for the measurement of pH of blood based on colorimetry
    Chaudhari, AL
    Patil, DD
    Shaligram, AD
    THIRD INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS AND THIRD CONFERENCE OF THE ASIAN-COMMITTEE-ON-EXPERIMENTAL-MECHANICS, PTS 1AND 2, 2005, 5852 : 223 - 227
  • [8] Noninvasive measurement of pH in platelet concentrates with a fiber optic fluorescence detector
    Reed, Mike W.
    Geelhood, Steve
    Barker, Lynn M.
    Pfalzgraf, Randy
    Vlaar, Richard
    Gouwerok, Eric
    De Cuyper, Iris M.
    Harris, Paul
    Verhoeven, Arthur J.
    de Korte, Dirk
    TRANSFUSION, 2009, 49 (06) : 1233 - 1241
  • [9] Tumor pH and Its Measurement
    Zhang, Xiaomeng
    Lin, Yuxiang
    Gillies, Robert J.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) : 1167 - 1170
  • [10] EXPERIMENTAL RESULTS ON AN OPTICAL PH MEASUREMENT SYSTEM FOR BIOREACTORS
    HOLOBAR, A
    WEIGL, BH
    TRETTNAK, W
    BENES, R
    LEHMANN, H
    RODRIGUEZ, NV
    WOLLSCHLAGER, A
    OLEARY, P
    RASPOR, P
    WOLFBEIS, OS
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3): : 425 - 430