Gas pixel chambers

被引:13
|
作者
Balagura, V
机构
[1] Institute for Theoretical and Experimental Physics, Moscow
关键词
D O I
10.1016/0168-9002(95)01042-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Gas pixel (pad) chambers are proposed to be used in the HERA-B experiment in the inner parts of both the high-p(t) pretrigger system and the muon system. The first prototypes have been built and successfully tested at ITEP, Moscow. An efficiency of 99.87% has been attained with a gas amplification of 10(4). A chamber with 10 x 10 mm(2) cells, filled with the gas mixture Ar/CF4 (80/20), allows detection of more than 99% of all particles within 80 ns. Stable operation was achieved with beam intensities of 3 x 10(5) particles/cm(2)/s without any visible degradation of the performance. Crosstalk between neighboring cells was studied and was found to be not larger than 1.5% and caused by delta-electrons.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 50 条
  • [31] Effect of a carrier gas on nucleation in diffusion chambers
    Itkin, A.L.
    Journal of Aerosol Science, 1998, 29 (SUPPL 1):
  • [32] CHANGE IN GAS COMPOSITION IN ENCLOSED SWITCH CHAMBERS
    NEUMEYER, V
    ELEKTROTECHNISCHE ZEITSCHRIFT ETZ-A, 1977, 98 (07): : 503 - 504
  • [33] Use of tungsten anodes in microgap gas chambers
    Cho, HS
    Palaio, N
    Hong, WS
    Kadyk, J
    Perez-Mendez, V
    Vujic, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 280 - 284
  • [34] Ageing of microstrip gas chambers: Problems and solutions
    Bouclier, R
    Capeans, M
    Garbatos, C
    Manzin, G
    Million, G
    Ropelewski, L
    Sauli, F
    Shekhtman, L
    Silander, K
    RopelewskiTemmel, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 381 (2-3): : 289 - 319
  • [35] A STUDY OF BREAKDOWN IN MICROSTRIP GAS-CHAMBERS
    DUERDOTH, I
    SNOW, S
    THOMPSON, R
    LUMB, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 356 - 360
  • [36] Performance and accurate measurement of microstrip gas chambers
    Hedianzixue Yu Tance Jishue, 5 (325-328):
  • [37] Thin Gap Gas Chambers for the DELPHI endcaps
    Adam, W
    Albrecht, E
    Bozzo, M
    Fontanelli, F
    Gracco, V
    Hrubec, J
    Mongiardini, E
    Morelli, A
    Morettini, P
    Petrolini, A
    Piana, G
    Ullaland, O
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 270 - 273
  • [38] Operation of sealed microstrip gas chambers at the ILL
    Clergeau, JF
    Convert, P
    Feltin, D
    Fischer, HE
    Guérard, B
    Hansen, T
    Manzin, G
    Oed, A
    Palleau, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1075 - 1080
  • [39] Operation of sealed microstrip gas chambers at the ILL
    Clergeau, JF
    Convert, P
    Feltin, D
    Fischer, HE
    Guerard, B
    Hansen, T
    Manzin, G
    Oed, A
    Palleau, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 60 - 68
  • [40] REPEATED USE OF SHIELDING GAS FOR WELDING IN CHAMBERS
    KAZAKOV, YV
    AKSENOV, NA
    ISHTYKOV, YV
    WELDING PRODUCTION, 1968, 15 (07): : 64 - &