DETERMINATION OF EPERISONE IN HUMAN PLASMA BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:9
|
作者
TAKAMATSU, T [1 ]
YAMAZAKI, K [1 ]
KAYANO, M [1 ]
TAKENAKA, F [1 ]
HASUI, M [1 ]
OHKAWA, T [1 ]
机构
[1] SEKISUI CHEM CO LTD,SEKISUI CLIN LAB,MISHIMA,OSAKA 618,JAPAN
来源
关键词
D O I
10.1016/0378-4347(92)80584-D
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A gas chromatographic-mass spectrometric method was developed to determine eperisone hydrochloride, 4'-ethyl-2-methyl-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2-40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml. the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.