摘要
The retrofit of dual-duct constant volume systems (DDCV) with energy-efficient variable air volume systems (VAV) has become common in recent years. In general, the energy savings from such retrofits are estimated by developing a temperature-dependent regression model using whole building preretrofit energy consumption data. Model predictions are then compared with measured post retrofit consumption, to determine the savings. In cases where the preretrofit energy consumption is not available such a method cannot be implemented. This paper describes a method that can be used to calculate savings in such cases. The method is based on use of simplified calibrated system models. A VAV model was developed based on the ASHRAE TC 4. 7 Simplified Energy Analysis Procedure (SEAP) (Knebel, 1983) and calibrated with the postretrofit energy consumption of a large engineering center in Central Texas. The loads from the calibrated VAV model were then used with the DDCV model to estimate the preretrofit energy use, also based on TC 4.7 SEAP, and apparent savings were determined as the difference between the DDCV predicted consumption and measured energy consumption for the postretrofit VAV system. The simulated hourly cooling energy consumption from the VAV model was within +/-1GJ (+/-20 percent) of the measured consumption. The simulated daily consumption (the sum of 24 hours of consumption) compared better with the measured daily consumption (within +/-7 percent). The apparent saving from the retrofit of the DDCV system with VA V was about 684 GJ in cooling energy and 324 GJ in heating energy for a three-week period June-July 1991.
引用
收藏
页码:57 / 68
页数:12
相关论文
共 50 条
  • [21] Misperceived energy use and savings
    Attari, Shahzeen Z.
    NATURE ENERGY, 2018, 3 (12): : 1029 - 1030
  • [22] Technical and economic assessment of a hybrid heat pump system as an energy retrofit measure in a residential building
    Saffari, Mohammad
    Keogh, David
    De Rosa, Mattia
    Finn, Donal P.
    ENERGY AND BUILDINGS, 2023, 295
  • [23] Impact of demand-side retrofit on the energy savings at the Universiti Teknologi Malaysia
    Majid, MS
    Taha, FM
    Maricar, NM
    Rahman, S
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 534 - 539
  • [24] Proposed Design Process for Deep Energy Savings in Commercial Building Retrofit Projects
    Parrish, Kristen
    Regnier, Cindy
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2013, 19 (02) : 71 - 80
  • [25] Asset management for Energy System Retrofit
    Varbanov P.S.
    Walmsley T.G.
    Klemeš J.J.
    Nemet A.
    Kravanja Z.
    Chemical Engineering Transactions, 2018, 70 : 775 - 780
  • [26] Use of simplified atmospheric models
    Thuburn, J
    NUMERICAL MODELING OF THE GLOBAL ATMOSPHERE IN THE CLIMATE SYSTEM, 2000, 550 : 105 - 118
  • [27] COMPARISON AND IMPLEMENTATION OF THERMALLY MASSIVE WALL AND ROOF MODELS FOR USE IN SIMPLIFIED BUILDING ENERGY MODELS
    Fernandez, Christopher
    Jeter, Sheldon
    PROCEEDINGS OF THE ASME 2020 14TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY (ES2020), 2020,
  • [28] COMPARISON AND IMPLEMENTATION OF THERMALLY MASSIVE WALL AND ROOF MODELS FOR USE IN SIMPLIFIED BUILDING ENERGY MODELS
    Fernandez, Christopher
    Jeter, Sheldon
    PROCEEDINGS OF THE ASME 13TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2019, 2019,
  • [29] Energy savings by the use of electricity in buildings
    Arribas, C
    Depreter, A
    Jackson, AN
    Jolion, M
    Lagergren, S
    Savignac, P
    Vanderschueren, G
    PROCEEDINGS OF THE XIII INTERNATIONAL CONGRESS ON ELECTRICITY APPLICATIONS, VOLS 1 AND 2, 1996, : BS61 - BS61
  • [30] USE OF OXYGEN AND ENERGY SAVINGS IN FOUNDRY
    SCIAMA, G
    FONDERIE, 1978, 33 (378): : 157 - 165