USE OF SIMPLIFIED SYSTEM MODELS TO MEASURE RETROFIT ENERGY SAVINGS

被引:21
|
作者
KATIPAMULA, S
CLARIDGE, DE
机构
[1] Energy Systems Laboratory, Department of Mechanical Engineering, Texas A and M University, College Station, TX
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 1993年 / 115卷 / 02期
关键词
D O I
10.1115/1.2930033
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The retrofit of dual-duct constant volume systems (DDCV) with energy-efficient variable air volume systems (VAV) has become common in recent years. In general, the energy savings from such retrofits are estimated by developing a temperature-dependent regression model using whole building preretrofit energy consumption data. Model predictions are then compared with measured post retrofit consumption, to determine the savings. In cases where the preretrofit energy consumption is not available such a method cannot be implemented. This paper describes a method that can be used to calculate savings in such cases. The method is based on use of simplified calibrated system models. A VAV model was developed based on the ASHRAE TC 4. 7 Simplified Energy Analysis Procedure (SEAP) (Knebel, 1983) and calibrated with the postretrofit energy consumption of a large engineering center in Central Texas. The loads from the calibrated VAV model were then used with the DDCV model to estimate the preretrofit energy use, also based on TC 4.7 SEAP, and apparent savings were determined as the difference between the DDCV predicted consumption and measured energy consumption for the postretrofit VAV system. The simulated hourly cooling energy consumption from the VAV model was within +/-1GJ (+/-20 percent) of the measured consumption. The simulated daily consumption (the sum of 24 hours of consumption) compared better with the measured daily consumption (within +/-7 percent). The apparent saving from the retrofit of the DDCV system with VA V was about 684 GJ in cooling energy and 324 GJ in heating energy for a three-week period June-July 1991.
引用
收藏
页码:57 / 68
页数:12
相关论文
共 50 条
  • [1] Assessment of energy savings by mechanical system retrofit of existing buildings
    Wang, Haidong
    Xue, Yuantao
    Mu, Yu
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2370 - 2377
  • [2] Assessment of the energy savings due to the building retrofit
    Zmeureanu, Radu
    1600, (25):
  • [3] ASSESSMENT OF THE ENERGY SAVINGS DUE TO THE BUILDING RETROFIT
    ZMEUREANU, R
    BUILDING AND ENVIRONMENT, 1990, 25 (02) : 95 - 103
  • [4] BOILER RETROFIT REAPS MAJOR ENERGY SAVINGS
    KATZEL, J
    PLANT ENGINEERING, 1983, 37 (21) : 42 - &
  • [5] EVALUATION OF MEASUREMENT AND VERIFICATION PROCEDURES FOR RETROFIT SAVINGS USING CALIBRATED ENERGY BUILDING MODELS
    Kalinic, Niko
    Krarti, Moncef
    ES2010: PROCEEDINGS OF ASME 4TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2010, : 363 - 373
  • [6] Green roofs; building energy savings and the potential for retrofit
    Castleton, H. F.
    Stovin, V.
    Beck, S. B. M.
    Davison, J. B.
    ENERGY AND BUILDINGS, 2010, 42 (10) : 1582 - 1591
  • [7] A simplified method to estimate energy savings of artificial lighting use from daylighting
    Krarti, M
    Erickson, PM
    Hillman, TC
    BUILDING AND ENVIRONMENT, 2005, 40 (06) : 747 - 754
  • [8] Measuring retrofit energy savings using autoassociative neural networks
    Jang, KJ
    Bartlett, EB
    Nelson, RM
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 2, 1996, 102 : 412 - 418
  • [9] Great energy predictor shootout II measuring retrofit savings
    Haberl, J.S.
    Thamilseran, S.
    ASHRAE Journal, 1998, 40 (01): : 49 - 56
  • [10] Energy retrofit of a historic building using simplified dynamic energy modeling
    Mancini, Francesco
    Cecconi, Marco
    De Sanctis, Francesca
    Beltotto, Andrea
    71ST CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION (ATI 2016), 2016, 101 : 1119 - 1126