Impact of an inverter-based DG on a double-ended fault location method

被引:3
|
作者
Jahanger, Hayder K. [1 ,2 ]
Thomas, David W. P. [1 ]
Sumner, Mark [1 ]
Rose, Christopher [1 ]
机构
[1] Univ Nottingham, Nottingham NG7 2RD, England
[2] Univ Technol Baghdad, Baghdad, Iraq
来源
关键词
distributed power generation; invertors; fault location; power distribution faults; inverter-based DG; double-ended fault location scheme; distributed generation; high-frequency fault transients; nonfundamental frequency current components; double-ended impedance-based fault location technique; high-frequency content; double-ended method; frequency; 5; 0; kHz;
D O I
10.1049/joe.2018.0261
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study describes the influence of distributed generation (DG) on a double-ended fault location based on measuring the high-frequency fault transients. The additional non-fundamental frequency current components from DG will influence the accuracy of an impedance-based fault location technique based on non-fundamental frequencies. A double-ended impedance-based fault location technique that utilises the high-frequency content (up to 5 kHz) is studied. This study showed that double-ended method is still able to locate a fault with a maximum error of 4% compared to the case without DG which showed a percentage error up to 2%.
引用
收藏
页码:1078 / 1083
页数:6
相关论文
共 50 条
  • [31] A new fault location scheme based on local measurements for transmission lines connected to inverter-based resources
    Mobashsher, Mohammad Mehdi
    Hosseini, Seyyed Mehdi
    Abdoos, Akbar
    Hashemi, Sayyed Mohammad
    Sanaye-Pasand, Majid
    Mehrjerdi, Hasan
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2024, 228
  • [32] yModel Explainable AI Method for Fault Detection in Inverter-Based Distribution Systems
    Reyes, Alejandro Montano
    Chengu, Ambe
    Gatsis, Nikolaos
    Ahmed, Sara
    Alamaniotis, Miltiadis
    [J]. 2024 IEEE TEXAS POWER AND ENERGY CONFERENCE, TPEC, 2024, : 502 - 507
  • [33] Rheological controllability of double-ended MR dampers subjected to impact loading
    Ahmadian, M
    Norris, JA
    [J]. SMART STRUCTURES AND MATERIALS 2004: DAMPING AND ISOLATION, 2004, 5386 : 185 - 194
  • [34] Research on Tree Flash Fault Localization of Hybrid Overhead-Underground Lines Based on Improved Double-Ended Traveling Wave Method
    Huang, Zukang
    Fang, Chunhua
    Jiang, Quancai
    Hu, Tao
    Lv, Junjie
    [J]. APPLIED SCIENCES-BASEL, 2024, 14 (11):
  • [35] The Impact of Inverter-based Generators on Machine Learning-based Transmission Line Fault Detector
    Al Kharusi, Khalfan
    El Haffar, Abdelsalam
    Mesbah, Mostefa
    [J]. 2021 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2021,
  • [36] A double-ended Raman temperature measurement method for hazardous chemicals warehouse
    Liu, Xue-jun
    Lu, Hao
    Yuan, Bi-xian
    Wei, Yu-chen
    Yan, Yong
    [J]. OPTIK, 2018, 169 : 62 - 68
  • [37] Research on fault location method in distribution network with DG based on PADEA
    Kang, Zhongjian
    Liu, Ruiying
    Feng, Yanyan
    [J]. Journal of Communications, 2015, 10 (08): : 621 - 628
  • [38] Optimal Active Fault Detection in Inverter-Based Grids
    Pirani, Mohammad
    Hosseinzadeh, Mehdi
    Taylor, Joshua A.
    Sinopoli, Bruno
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2023, 31 (03) : 1411 - 1417
  • [39] Wavelet neural network based on islanding detection via inverter-based DG
    Mohammadi, Mohsen
    Danandeh, Akbar
    Aghdam, Hossein Nasir
    Ojaroudi, Nasser
    [J]. COMPLEXITY, 2015, 21 (02) : 309 - 324
  • [40] Fault Current Negative Contribution Method for Inverter-Based Distributed Generators Under Grid Unbalanced Fault
    Liu, Xubin
    [J]. IEEE ACCESS, 2020, 8 : 220807 - 220815