A Case Study of an Optimal Detailed Analysis of a Standalone Photovoltaic/Battery System for Electricity Supply in Rural and Remote Areas

被引:0
|
作者
Falama, Ruben Zieba [1 ,2 ]
Yaouba, Francis-Daniel [2 ,3 ]
Menga, Francis-Daniel [4 ]
Soulouknga, Marcel Hamda [5 ]
Mbakop, Fabrice Kwefeu [3 ,6 ,7 ]
机构
[1] Univ Maroua, Higher Natl Sch Mines & Petr Ind, POB 46, Maroua, Cameroon
[2] Inst Geol & Min Res, Res Ctr Renewable Energy, POB 4110, Yaounde, Cameroon
[3] Univ TMaroua, Natl Adv Polytech Sch, Dept Renewable Energy, POB 46, Maroua, Cameroon
[4] Natl Ctr Technol Dev, Yaounde, Cameroon
[5] Higher Teacher Training Tech Coll Sarh, Sarh, Chad
[6] Univ Monastir, LASEE Lab, Monastir, Tunisia
[7] Univ Sousse, ISSAT Sousse, Sousse, Tunisia
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper focused on a techno-economic study of a standalone PV/battery system for electrical energy supply. For a particular case study in Cameroon, the system is optimally designed thanks to a double-objective firefly optimization algorithm, based on a defined operational strategy. The two objective functions simulated simultaneously using FA are: the cost of energy (COE) function and the function defining the loss of power supply probability (LPSP). Different optimal configurations of the system have been obtained on the Pareto front with respect to their LPSP. For a total load demand of 20196.7 kWh, the lowest cost configuration with LPSP of 0% is composed by a number of 63 modules and a battery capacity of 370.295 kWh. The related COE is 0.2587 $/kWh, corresponding to a total net present cost of 87422 $. However with this configuration, the energy of batteries could not be able solely to respond to the energy demand for 3 continuous days. In that case, the increase of the PV power production (by increasing the number of PV modules) could allow to the batteries to fulfil this deficiency. But this solution increases the investment cost to up to 11.17%, considering a system with 80 PV modules. Another solution consists in reducing the size of the battery bank to avoid its unnecessary oversizing. In this case, the COE and the system investment cost reduce to up to 28.77% for 1 day batteries' autonomy considered. The obtained results have demonstrated that the cost of a PV/battery system is mostly influenced by the batteries' size, while the system reliability is mostly related to the PV size.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Optimal Approach to Photovoltaic Electricity Injection in an Unstable Grid: Case Study
    Ouedraogo, Seydou
    Nikiema, Ousmane
    Tissologo, Moussa
    Nanema, Emmanuel
    Salami, Adekunlé Akim
    Journal of Engineering Science and Technology Review, 2024, 17 (06) : 132 - 139
  • [32] Long term performance analysis of a 19.8kWp standalone photovoltaic system in a remote island
    Ma, Tao
    Yang, Hongxing
    Lu, Lin
    PROCEEDINGS OF RENEWABLE ENERGY INTEGRATION WITH MINI/MICROGRID (REM2016), 2016, 103 : 183 - 188
  • [33] A Comparative Study of GA and APSO algorithm for an Optimal design of a standalone PV/Battery system
    Elloumi, Mariem
    Kallel, Randa
    Boukettaya, Ghada
    2018 15TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS AND DEVICES (SSD), 2018, : 1104 - 1109
  • [34] Optimal Design of Standalone Photovoltaic System Based on Multi-Objective Particle Swarm Optimization: A Case Study of Malaysia
    Ridha, Hussein Mohammed
    Gomes, Chandima
    Hizam, Hashim
    Ahmadipour, Masoud
    PROCESSES, 2020, 8 (01)
  • [35] Solar battery power supply: A reliable power supply system for nursing clinic in Australia's remote areas
    Zahedi, A
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 1911 - 1914
  • [36] A novel framework for optimal photovoltaic size and location in remote areas using a hybrid method: A case study of eastern Iran
    Maleki, Akbar
    Pourfayaz, Fathollah
    Hafeznia, Hamed
    Rosen, Marc A.
    ENERGY CONVERSION AND MANAGEMENT, 2017, 153 : 129 - 143
  • [37] Feasibility study of the use of a hydrogen-based storage system as an alternative to battery storage of a standalone photovoltaic installation to supply a house's electric demand
    Delgado Fernandez, Salvador
    Pino Lucena, Francisco Javier
    Rosa Iglesias, Manuel Felipe
    2019 2ND INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES (SEST 2019), 2019,
  • [38] Extreme low-maintenance, lead/acid battery for photovoltaic power-supply systems in remote, tropical areas
    United Accumulators Private Ltd, Corlim-Goa, India
    Journal of Power Sources, 1995, 53 (2 pt 2): : 255 - 260
  • [39] Techno-Economic Analysis of Solar PV Electricity Supply to Rural Areas of Balochistan, Pakistan
    Shah, Syed Ahsan Ali
    Das Valasai, Gordhan
    Memon, Asif Ali
    Laghari, Abdul Nasir
    Jalbani, Nabi Bux
    Strait, Jody L.
    ENERGIES, 2018, 11 (07):
  • [40] Optimal techno-economic sizing of a standalone floating photovoltaic/ battery energy storage system to power an aquaculture aeration and monitoring system
    Jamroen, Chaowanan
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 50