DOSE IN BONE AND TISSUE NEAR BONE-TISSUE INTERFACE FROM ELECTRON-BEAM

被引:11
|
作者
SHIU, AS
HOGSTROM, KR
机构
[1] Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX 77030
关键词
ELECTRON BACKSCATTER FACTOR; ELECTRON BEAM; BONE-TISSUE INTERFACE; INHOMOGENEOUS PHANTOM;
D O I
10.1016/0360-3016(91)90688-Z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This work has quantitatively studied the variation of dose both within bone and in unit density tissue near bone-tissue interfaces. Dose upstream of a bone-tissue interface is increased because of an increase in the backscattered electrons from the bone. The magnitude of this effect was measured using a thin parallel-plate ionization chamber upstream of a polymethyl methacrylate (PMMA)-hard bone interface. The electron backscatter factor (EBF) increased rapidly with bone thickness until a full EBF was achieved. This occurred at approximately 3.5 mm at 2 MeV and 6 mm at 13.1 MeV. The full EBF at the interface ranged from approximately 1.018 at 13.1 MeV to 1.05 at 2 MeV. It was also observed that the EBF had a dependence on the energy spectrum at the interface. The penetration of the backscattered electrons in the upstream direction of PMMA was also measured. The dose penetration fell off rapidly in the upstream direction of the interface. Dose enhancement to unit density tissue in bone was measured for an electron beam by placing thermoluminescent dosimeters (TLDs) in a PMMA-bone-PMMA phantom. The maximum dose enhancement in bone was approximately 7% of the maximum dose in water. However, the pencil-beam algorithm of Hogstrom et al. predicted an increase of only 1%, primarily owing to the inverse-square correction. Film was also used to measure the dose enhancement in bone. The film plane was aligned either perpendicular or parallel to the central axis of the beam. The film data indicated that the maximum dose enhancement in bone was approximately 8% for the former film alignment (which was similarly predicted by the TLD measurements) and 13% for the latter film alignment. These results confirm that the X ray film is not suitable to be irratiated "edge on" in an inhomogeneous phantom without making perturbation corrections resulting from the film acting as a long narrow inhomogeneous cavity within the bone. In addition, the results give the radiotherapist a basis for clinical judgment when electron beams are used to treat lesions behind bone or near bony structures. We feel these data enhance the ability to recognize the shortcomings of the current dose calculation algorithm used clinically.
引用
收藏
页码:695 / 702
页数:8
相关论文
共 50 条
  • [1] DOSE IN BONE AND TISSUE NEAR BONE-TISSUE INTERFACES FOR ELECTRON-BEAMS
    SHIU, AS
    HOGSTROM, KR
    [J]. MEDICAL PHYSICS, 1984, 11 (03) : 378 - 378
  • [2] DOSE ACROSS A PLANE BONE-TISSUE INTERFACE
    KULKARNI, RN
    SUNDARARAMAN, V
    PRASAD, MA
    [J]. RADIATION RESEARCH, 1972, 51 (01) : 1 - +
  • [3] RECOIL PROTON DOSE AT A BONE-TISSUE INTERFACE IRRADIATED BY FAST NEUTRONS
    LAWSON, RC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (04): : 551 - &
  • [4] RECOIL PROTON DOSE ACROSS A BONE-TISSUE INTERFACE DUE TO FAST NEUTRONS
    PRASAD, MA
    SUNDARARAMAN, V
    VENKATARAMAN, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (03): : 461 - +
  • [5] FAST-NEUTRON DOSIMETRY OF A BONE-TISSUE INTERFACE
    BHATIA, DP
    NAGARAJAN, PS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (01): : 166 - 170
  • [6] A Monte Carlo study of bone-tissue interface microdosimeters
    Cho, I-Chun
    Chen, Fang-Hsin
    Chao, Tsi-Chian
    Tung, Chuan-Jong
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 140 : 193 - 200
  • [7] DOSE CORRECTION FACTORS AT THE BONE-TISSUE INTERFACE FOR HIGH-ENERGY PHOTON BEAMS
    REFT, CS
    KUCHNIR, FT
    [J]. MEDICAL PHYSICS, 1986, 13 (04) : 589 - 589
  • [8] Scaffolds for bone-tissue engineering
    Lee, Seunghun S.
    Du, Xiaoyu
    Kim, Inseon
    Ferguson, Stephen J.
    [J]. MATTER, 2022, 5 (09) : 2722 - 2759
  • [9] IMPACT OF CORTICOSTEROIDS ON BONE-TISSUE
    KAISER, H
    [J]. ZEITSCHRIFT FUR RHEUMATOLOGIE, 1989, 48 : 21 - 26
  • [10] Fabrication of Scaffolds for Bone-Tissue Regeneration
    Chocholata, Petra
    Kulda, Vlastimil
    Babuska, Vaclav
    [J]. MATERIALS, 2019, 12 (04)