Nonlinear analysis of r.c. framed buildings retrofitted with elastomeric and friction bearings under near-fault earthquakes

被引:4
|
作者
Mazza, Mirko [1 ]
机构
[1] Univ Calabria, Dipartimento Ingn Civile, Cubo 39b, I-87030 Arcavacata Di Rende, CS, Italy
关键词
R.c. base-isolated structures; Elastomeric bearings; Friction bearings; Nonlinear dynamic analysis;
D O I
10.1007/s11589-015-0133-0
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Reinforced concrete (r.c.) framed buildings designed in compliance with inadequate seismic classifications and code provisions present in many cases a high vulnerability and need to be retrofitted. To this end, the insertion of a base isolation system allows a considerable reduction of the seismic loads transmitted to the superstructure. However, strong near-fault ground motions, which are characterised by long-duration horizontal pulses, may amplify the inelastic response of the superstructure and induce a failure of the isolation system. The above considerations point out the importance of checking the effectiveness of different isolation systems for retrofitting a r.c. framed structure. For this purpose, a numerical investigation is carried out with reference to a six-storey r.c. framed building, which, primarily designed (as to be a fixed-base one) in compliance with the previous Italian code (DM96) for a medium-risk seismic zone, has to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by the current Italian code (NTC08) in a high-risk seismic zone. Besides the (fixed-base) original structure, three cases of base isolation are studied: elastomeric bearings acting alone (e.g. HDLRBs); in-parallel combination of elastomeric and friction bearings (e.g. high-damping-laminated-rubber bearings, HDLRBs and steel-PTFE sliding bearings, SBs); friction bearings acting alone (e.g. friction pendulum bearings, FPBs). The nonlinear analysis of the fixed-base and base-isolated structures subjected to horizontal components of near-fault ground motions is performed for checking plastic conditions at the potential critical (end) sections of the girders and columns as well as critical conditions of the isolation systems. Unexpected high values of ductility demand are highlighted at the lower floors of all base-isolated structures, while re-centring problems of the base isolation systems under near-fault earthquakes are expected in case of friction bearings acting alone (i.e. FPBs) or that in combination (i.e. SBs) with HDLRBs.
引用
收藏
页码:365 / 377
页数:13
相关论文
共 50 条
  • [41] Comparative analysis of the dynamic behavior of structures equipped with cylindrical and spherical frictional bearings subjected to near-fault earthquakes
    Auad, Gaspar
    Almazan, Jose L.
    Vilca, Federico
    STRUCTURES, 2024, 60
  • [42] Seismic Analysis of Adjacent Inelastic Structures Connected with Hysteretic Dampers under Near-Fault Earthquakes
    Huang, X.
    Zhu, H. P.
    Hu, Z. X.
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (09) : 1487 - 1497
  • [43] Seismic Analysis of Reinforced Concrete Silos under Far-Field and Near-Fault Earthquakes
    Hussein A.H.
    Risan H.K.
    SDHM Structural Durability and Health Monitoring, 2022, 16 (03): : 213 - 233
  • [44] Experimental study on the effect of nonlinear viscous dampers on base-isolated structures under near-fault earthquakes
    Lyu, Qing
    Zhang, Haiqi
    Fu, Bo
    Zhu, Baijie
    Liu, Liangkun
    STRUCTURES, 2024, 61
  • [45] Sensitivity analysis of variable curvature friction pendulum isolator under near-fault ground motions
    Shahbazi, Parisa
    Taghikhany, Touraj
    SMART STRUCTURES AND SYSTEMS, 2017, 20 (01) : 23 - 33
  • [46] Study on the Seismic Response Parameters of Steel Medium-Height Buildings with Framed-Tube Skeleton under Near-Fault Records
    Azhdarifar, M.
    Meshkat-Dini, A.
    Sarvghad-Moghadam, A.
    ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2015, 15 (01): : 70 - 87
  • [47] Effects of nonlinear modelling of the base-isolation system on the seismic analysis of r.c. buildings
    Mazza, Fabio
    Labernarda, Rodolfo
    XIV INTERNATIONAL CONFERENCE ON BUILDING PATHOLOGY AND CONSTRUCTIONS REPAIR, 2018, 11 : 226 - 233
  • [48] Nonlinear dynamic characteristics of coupled tank-isolator interactive systems under different types of near-fault earthquakes
    Barik, Jyoti Ranjan
    Biswal, Kishore Chandra
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2024, 184
  • [49] Response and protection of the impact of base-friction-isolated structures and displacement-constraint devices under near-fault earthquakes
    Fan, Jian
    Liu, Tie
    Wei, Junjie
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2007, 40 (05): : 10 - 16
  • [50] Reviewing dynamic analysis of base-isolated cylindrical liquid storage tanks under near-fault earthquakes
    Saha, Sandip Kumar
    Matsagar, Vasant A.
    Jain, Arvind K.
    IES Journal Part A: Civil and Structural Engineering, 2015, 8 (01): : 41 - 61