Lead isotope measurement using a multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)

被引:5
|
作者
Choi, Hye-Bin [1 ,2 ]
Ryu, Jong-Sik [1 ]
Park, Sanghee [1 ]
Lee, Jeonghoon [2 ]
机构
[1] Korea Basic Sci Inst, Div Earth & Environm Sci, Chungbuk 28119, South Korea
[2] Ewha Womans Univ, Dept Sci Educ, Seoul 03760, South Korea
关键词
Pb isotopes; chemical separation; MC-ICP-MS; environmental sample;
D O I
10.14770/jgsk.2018.54.3.311
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Lead (Pb) as a trace element occurs in rocks and has four stable isotopes (Pb-204, Pb-206, Pb-207, Pb-208). Pb is released into the atmosphere, biosphere, hydrosphere and geosphere through various industrial activities, such as smelter, mining, combustion of fossil fuels and use of leaded gasoline, and result in serious environmental contamination. Pb isotopes can be used to trace the Pb contamination source and to understand of the biogeochemical cycling of Pb in the environment. Pb purification with two-step chemical separation using hydrochloric acid (HCl) and hydrogen bromide (HBr) can yield high precise and accurate results although it needs a lot of time and labor during Pb purification. Here, we developed one-step chemical separation using only HCl. In order to develop an efficient separation method, two kinds of ion exchange resins, Eichrom Sr-resin and Pb-resin, were used to compare the separation and recovery of Pb from other matrix elements. Further, in order to verify this method we measured Pb isotopes in several geological reference materials distributed by USGS and NRCC. The results are consistent with the reported values within the error, indicating that this method is successfully developed. It is expected that this study can be broadly used to measure Pb isotopes in various environmental samples.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [21] Precise determination of rhenium isotope composition by multi-collector inductively-coupled plasma mass spectrometry
    Miller, Christian A.
    Peucker-Ehrenbrink, Bernhard
    Ball, Lary
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (08) : 1069 - 1078
  • [22] Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Varga, Z.
    Krachler, M.
    Nicholl, A.
    Ernstberger, M.
    Wiss, T.
    Wallenius, M.
    Mayer, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 1076 - 1080
  • [23] Determination of Stable Silicon Isotopes Using Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang An-Yu
    Zhang Jing
    Zhang Rui-Feng
    Xue Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1353 - 1358
  • [24] Measurement of U and Pu isotope ratios in hair and nail samples using extraction chromatography and multi-collector inductively coupled plasma mass spectrometry
    Brown, J. N. W.
    Robertson, J. D.
    Brockman, J. D.
    TALANTA, 2014, 129 : 481 - 485
  • [25] Measurement of U and Pu isotope ratios in hair and nail samples using multi-collector inductively coupled plasma mass spectrometry and extraction chromatography
    Brockman, John D.
    Brown, John W.
    Robertson, J. David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [26] Hf isotope ratio analysis using multi-collector inductively coupled plasma mass spectrometry: an evaluation of isobaric interference corrections
    Chu, NC
    Taylor, RN
    Chavagnac, V
    Nesbitt, RW
    Boella, RM
    Milton, JA
    German, CR
    Bayon, G
    Burton, K
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (12) : 1567 - 1574
  • [27] DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS)
    LONGERICH, HP
    FRYER, BJ
    STRONG, DF
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) : 39 - 48
  • [28] Lead isotope ratios in lead-glazed ceramics determined by laser ablation multi-collector inductively coupled plasma mass spectrometry for discriminating purpose
    Zong, Chunlei
    Bao, Zhian
    Ran, Wangli
    Ling, Xue
    Chen, Lu
    Chen, Kaiyun
    Yuan, Honglin
    ANALYTICAL METHODS, 2018, 10 (21) : 2456 - 2463
  • [29] Enhanced sensitivity in laser ablation multi-collector inductively coupled plasma mass spectrometry
    Cottle, John M.
    Burrows, Andrew J.
    Kylander-Clark, Andrew
    Freedman, Philip A.
    Cohen, Roy S.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1700 - 1706
  • [30] High spatial resolution analysis of Pb and U isotopes for geochronology by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS)
    Buhn, Bernhard
    Pimentel, Marcio M.
    Matteini, Massimo
    Dantas, Elton L.
    ANAIS DA ACADEMIA BRASILEIRA DE CIENCIAS, 2009, 81 (01): : 99 - 114