REPRODUCIBILITY OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM

被引:30
|
作者
ENGEL, TR [1 ]
PIERCE, DL [1 ]
PATIL, KD [1 ]
机构
[1] UNIV NEBRASKA,MED CTR,COLL MED,DEPT PREVENT & SOCIETAL MED,OMAHA,NE 68198
关键词
D O I
10.1016/0002-8703(91)90283-N
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Variation in measurements made from signal-averaged electrocardiograms was examined. Averaging 200 beats in 18 normal subjects, pairs of high-frequency QRS and low-amplitude signal durations correlated at immediate, short-term, and long-term intervals. The percent high-frequency (60 Hz to 120 Hz) voltages in the late potential region had modest correlations. However, 95% confidence intervals of differences in paired measurements were as much as 7% for high-frequency QRS, 20% for a low-amplitude signal, and 53% for percent high-frequency, similar at all time intervals. With electrocardiograms averaged to 0.3-mu-V noise, high-frequency QRS and low-amplitude signals prolonged, but variation was similar to that of 200 beat pairs. In contrast, low noise reduced percent high-frequency and lessened variation to 29%. Therefore variation in signal-averaged electrocardiographic measurements was considerable (high-frequency voltage > durations). Noise did not appreciably influence variation in durations but was critical to consistent voltage measurements in the frequency domain.
引用
收藏
页码:1652 / 1660
页数:9
相关论文
共 50 条
  • [31] THE EFFECTS OF EXERCISE DURING VIREMIA ON THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    VACEK, JL
    SMITH, GS
    AMERICAN HEART JOURNAL, 1990, 119 (03) : 702 - 705
  • [32] THE EFFECTS OF SMOKING ON THE SIGNAL-AVERAGED ELECTROCARDIOGRAM IN NORMAL SUBJECTS
    SPERRY, RE
    VACEK, JL
    SMITH, GS
    CHEST, 1991, 99 (01) : 121 - 122
  • [33] EFFECTS OF MEXILETINE, PROPAFENONE AND FLECAINIDE ON SIGNAL-AVERAGED ELECTROCARDIOGRAM
    LOMBARDI, F
    FINOCCHIARO, ML
    VECCHIA, LD
    RECH, R
    CASTELLI, A
    PASTINE, J
    CAPPIELLO, E
    EUROPEAN HEART JOURNAL, 1992, 13 (04) : 517 - 525
  • [34] OBSTRUCTIVE SLEEP-APNEA AND SIGNAL-AVERAGED ELECTROCARDIOGRAM
    ANDREAS, S
    VONBRESKA, B
    SCHAUMANN, A
    GONSKA, BD
    KREUZER, H
    EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (04) : 546 - 550
  • [35] Effect of slow coronary flow on signal-averaged electrocardiogram
    Nough, Hossein
    Khoshnood, Elahe Rafiei
    Naghedi, Aryan
    Hadiani, Leila
    Jorat, Mohammad Vahid
    CARDIOMETRY, 2018, (13): : 42 - 47
  • [36] SPONTANEOUS MYOCARDIAL-ISCHEMIA AND THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    TURITTO, G
    CAREF, EB
    ZANCHI, E
    MENGHINI, F
    KELEN, G
    ELSHERIF, N
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (08): : 676 - 680
  • [37] EFFECTS OF HEART-RATE ON SIGNAL-AVERAGED ELECTROCARDIOGRAM
    NAKAGAWA, M
    WATANABE, M
    ISHIDA, S
    YONEMOCHI, H
    FUJINO, T
    SAIKAWA, T
    ITO, M
    CIRCULATION, 1994, 90 (04) : 389 - 389
  • [38] EFFECT OF SUCCESSFUL CORONARY ANGIOPLASTY ON THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    MANOLIS, AS
    KATSAROS, C
    FOUSSAS, S
    OLYMPIOS, C
    FAKIOLAS, C
    COKKINOS, DV
    MORA, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (06): : 950 - 956
  • [39] A PROSPECTIVE EVALUATION OF THE IMMEDIATE REPRODUCIBILITY OF THE SIGNAL-AVERAGED ECG
    SAGER, PT
    WIDERHORN, J
    PASCUAL, M
    LEON, C
    RAHIMTOOLA, SH
    BHANDARI, AK
    AMERICAN HEART JOURNAL, 1991, 121 (06) : 1671 - 1678
  • [40] FREQUENCY VERSUS TIME-DOMAIN ANALYSIS OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM - REPRODUCIBILITY OF THE SPECTRAL TURBULENCE ANALYSIS
    KULAKOWSKI, P
    MALIK, M
    ODEMUYIWA, O
    STAUNTON, A
    CAMM, AJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (05): : 1027 - 1036