The Cirrus Diagnostics IMMULITE(TM) is a random access automated immunoassay system built around a proprietary assay tube that provides for rapid and efficient washing of the captive antibody coated bead by spinning the tube on its vertical axis. Sample, excess reagent, and wash solution are captured in a coaxial waste sump integral with the tube. The alkaline phosphatase label is measured using a sensitive chemiluminescent substrate. System operation is very simple. The operator loads a carousel with label reagent for up to twelve resident assays. Samples in bar coded tubes are placed onto a continuous conveyer followed by up to five different assay tubes in any order. Samples can be added at any time and stats can be inserted as the next sample to be processed with no loss in throughput. Throughput is 120 tests per hour and the first result is available in 45 minutes. Periodic calibration of the stored standard curves is done with two calibrators which are loaded just like samples.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [31] Basiliximab interferes with the detection of soluble IL-2 receptor by the Immulite Immunoassay system
    Warlé, MC
    Kwekkeboom, J
    Tilanus, HW
    Metselaar, HJ
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 275 (1-2) : 133 - 136
  • [32] AN AUTOMATED CHEMILUMINESCENT ASSAY FOR INTACT PARATHYROID-HORMONE ON THE IMMULITE SYSTEM
    CCCCHCTTIN, M
    CRAPANZANO, C
    [J]. CLINICAL CHEMISTRY, 1995, 41 (06) : S50 - S50
  • [33] EVALUATION OF THE AFFINITY AUTOMATED IMMUNOASSAY SYSTEM
    BRUZEK, D
    DREW, H
    REGALADO, J
    CHAN, DW
    [J]. CLINICAL CHEMISTRY, 1989, 35 (06) : 1188 - 1188
  • [34] THE ANAGEN SYSTEM FOR AUTOMATED FLUOROMETRIC IMMUNOASSAY
    CLEMENTS, JA
    FORREST, GC
    JAY, RF
    JEFFERY, M
    KEMP, PM
    KJELDSEN, NJ
    RATTLE, SJ
    SMITH, A
    [J]. CLINICAL CHEMISTRY, 1992, 38 (09) : 1671 - 1677
  • [35] FLUORESCENT IMMUNOASSAY SYSTEM - AUTOMATED INSTRUMENTATION
    SIMONSEN, MG
    CURRY, RE
    [J]. CLINICAL CHEMISTRY, 1979, 25 (06) : 1116 - 1116
  • [36] MODIFIED SAMPLE-CUP HOLDER IMPROVES WORK FLOW IN IMMULITE IMMUNOASSAY SYSTEM
    VANDERHORST, FAL
    BOS, W
    [J]. CLINICAL CHEMISTRY, 1995, 41 (10) : 1541 - 1541
  • [37] Assays for monitoring serum carbamazepine, phenytoin, valproic acid and phenobarbital on the IMMULITE® 2000 automated immunoassay analyzer.
    Wen-Quinto, J
    McKenna, MC
    Lei, JD
    Panosian-Sahakian, N
    Unver, E
    El Shami, AS
    [J]. CLINICAL CHEMISTRY, 2000, 46 (06) : A199 - A200
  • [38] Evaluation of anti HBs and anti HBc chemiluminescent enzyme immunoassay on the IMMULITE® system.
    Emanuelli, B
    Crapanzano, C
    Mazzocchi, GC
    Cecchettin, M
    [J]. CLINICAL CHEMISTRY, 1999, 45 (06) : A158 - A159
  • [39] An automated cirrus classification
    Gryspeerdt, Edward
    Quaas, Johannes
    Goren, Tom
    Klocke, Daniel
    Brueck, Matthias
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2018, 18 (09) : 6157 - 6169
  • [40] Three new assays for monitoring serum carbamazepine, phenytoin and valproic acid on the IMMULITE® automated immunoassay analyzer.
    Adams, SB
    Wen-Quinto, J
    Lei, JD
    Unver, E
    El Shami, AS
    [J]. CLINICAL CHEMISTRY, 1999, 45 (06) : A121 - A121