ENHANCED PRESERVATION OF ACUTELY ISCHEMIC MYOCARDIUM WITH TRANSSEPTAL LEFT-VENTRICULAR ASSIST

被引:19
|
作者
FONGER, JD [1 ]
ZHOU, Y [1 ]
MATSUURA, H [1 ]
ALDEA, GS [1 ]
SHEMIN, RJ [1 ]
机构
[1] UNIV BOSTON HOSP,MED CTR,DEPT CARDIOTHORAC SURG,BOSTON,MA 02118
来源
ANNALS OF THORACIC SURGERY | 1994年 / 57卷 / 03期
关键词
D O I
10.1016/0003-4975(94)90547-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Mechanical support for acute regional ischemia without hemodynamic collapse may be achieved percutaneously with an intraaortic balloon pump (IABP) or with transseptal left ventricular assist (TLVA) while awaiting revascularization. The relative benefits of these two percutaneous transfemoral techniques for the treatment of ischemia were compared in a representative animal model. During 90 minutes of regional coronary occlusion, four groups of 8 pigs were treated with either no support (control), IABF, TLVA, or both IABP and TLVA. Cardioplegic arrest for 30 minutes to simulate coronary grafting was followed by 180 minutes of global reperfusion on bypass. In all groups regional wall motion and interstitial pH in the area at risk were significantly depressed with ischemia, but wall motion fully recovered after reperfusion. However, histochemical staining of the area of necrosis/area at risk was significantly reduced with IABP versus control (20.2% versus 34.1%; p < 0.05) and further significantly reduced with TLVA and IABP + TT,VA (10.7% and 6.7% versus IABP alone; p < 0.05). We conclude that in supporting even a modest-sized myocardial region at risk (12% of the left ventricle) the area that went on to infarction was significantly reduced with the use of TLVA over IABP. Regional wall motion and myocardial pH measurements did not reflect this difference in the early reperfusion period. The benefit of TLVA over IABP during more extensive or prolonged ischemia may have real clinical significance.
引用
收藏
页码:570 / 575
页数:6
相关论文
共 50 条
  • [41] DEVELOPMENT OF A PIEZOELECTRIC LEFT-VENTRICULAR ASSIST DEVICE
    ONEILL, CG
    SMILEY, PC
    SMART, DL
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1975, 11 (05) : 963 - 964
  • [42] ETHICAL CONSIDERATIONS OF LEFT-VENTRICULAR ASSIST DEVICE
    不详
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (08): : 823 - 824
  • [43] DYNAMIC AORTOMYOPLASTY TO ASSIST LEFT-VENTRICULAR FAILURE
    CHACHQUES, JC
    GRANDJEAN, PA
    FISCHER, EIC
    LATREMOUILLE, C
    JEBARA, VA
    BOURGEOIS, I
    CARPENTIER, A
    ANNALS OF THORACIC SURGERY, 1990, 49 (02): : 225 - 230
  • [44] DEVELOPMENT OF AN IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE
    LIAPIS, CD
    LEVINE, FH
    NUGENT, WC
    KYO, S
    TSAI, CH
    SINGH, PI
    ADAMS, B
    PETSCHEK, H
    AUSTEN, WG
    BUCKLEY, MJ
    SURGICAL FORUM, 1981, 32 : 244 - 246
  • [45] THE PUCA PUMP - A LEFT-VENTRICULAR ASSIST DEVICE
    VERKERKE, B
    DEMUINCK, ED
    RAKHORST, G
    BLANKSMA, PK
    ARTIFICIAL ORGANS, 1993, 17 (05) : 365 - 368
  • [46] EVALUATION OF A NONHEMOLYTIC LEFT-VENTRICULAR ASSIST PUMP
    MYEROWITZ, PD
    NERZ, FR
    JOHNSON, FW
    BLACKSHEAR, PS
    NICOLOFF, DM
    JOURNAL OF SURGICAL RESEARCH, 1976, 20 (05) : 493 - 498
  • [47] Patient selection for left-ventricular assist devices
    Lietz, Katherine
    Miller, Leslie W.
    CURRENT OPINION IN CARDIOLOGY, 2009, 24 (03) : 246 - 251
  • [48] LEFT-VENTRICULAR ASSIST DEVICE SYSTEM CONSIDERATIONS
    MOISE, JC
    BUTLER, KC
    WAMPLER, R
    FUJIMOTO, L
    SMITH, W
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 564 - 564
  • [49] IMAGING AND COMPLICATIONS OF LEFT-VENTRICULAR ASSIST DEVICES
    ROACH, NA
    ARMAH, KO
    TODD, BA
    RADIOLOGY, 1995, 197 : 518 - 518
  • [50] THERAPEUTIC EFFECT OF LEFT-VENTRICULAR ASSIST DEVICE ON INDUCED PROFOUND LEFT-VENTRICULAR FAILURE - EVALUATION BY LEFT VENTRICULOGRAPHY
    NAKATANI, T
    TAKANO, H
    TAENAKA, T
    UMEZU, M
    TANAKA, T
    YUTANI, C
    MATSUDA, T
    IWATA, H
    NODA, H
    NAKAMURA, T
    TAKATANI, S
    SEKI, J
    HAYASHI, K
    AKUTSU, T
    MANABE, H
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1984, 30 : 533 - 539