PULSED MAGNETIZATION TRANSFER VERSUS CONTINUOUS WAVE IRRADIATION FOR TISSUE CONTRAST ENHANCEMENT

被引:39
|
作者
SCHNEIDER, E
PROST, RW
GLOVER, GH
机构
[1] Applied Science Laboratory, W-875, GE Medical Systems, Waukesha, Wisconsin, 5318
[2] Department of Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin
[3] Department of Diagnostic Radiology, Stanford University School of Medicine, Stanford, California
来源
关键词
CONTRAST ENHANCEMENT; MAGNETIZATION TRANSFER CONTRAST; PULSE SEQUENCES;
D O I
10.1002/jmri.1880030218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Pulsed magnetization transfer and continuous wave irradiation techniques are analyzed and compared for saturation efficiency and radio-frequency (RF) power requirements at 1.5 and 0.5 T. Binomial RF pulses transmitted on resonance are a more power-efficient method of exciting saturation transfer and are easily implemented with any pulse sequence. Binomial pulses selectively excite all short T2 species and behave as 0 pulses for on-resonance, long T2 species.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 50 条
  • [21] OPTIMIZATION OF PULSED MAGNETIZATION TRANSFER FOR ENHANCED SYNOVIAL-FLUID ARTICULAR-CARTILAGE CONTRAST
    SCHNEIDER, E
    BROWN, SM
    BRADLEY, WG
    RADIOLOGY, 1992, 185 : 158 - 158
  • [22] Comparison of phototoxicity mechanism between pulsed and continuous wave irradiation in photodynamic therapy
    Miyamoto, Y
    Umebayashi, Y
    Nishisaka, T
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1999, 53 (1-3) : 53 - 59
  • [23] Comparative disinfection efficiency of pulsed and continuous-wave UV irradiation technologies
    Bohrerova, Zuzana
    Shemer, Hilla
    Lantis, Robert
    Impellitteri, Christopher A.
    Linden, Karl G.
    WATER RESEARCH, 2008, 42 (12) : 2975 - 2982
  • [24] Irradiation of successive pulsed and continuous-wave lasers on a transparent polyethylene film
    Song, Changqing
    Han, Kai
    Li, Xiao
    Cui, Wenda
    Xu, Xiaojun
    OPTICAL ENGINEERING, 2020, 59 (12)
  • [25] A comparison of continuous versus pulsed wave ultrasound in inducing thrombolysis with microbubbles
    Porter, TR
    Xie, F
    Kricsfeld, D
    CIRCULATION, 2000, 102 (18) : 562 - 562
  • [26] MAGNETIZATION-TRANSFER TISSUE CONTRAST MAY DIFFERENTIATE BETWEEN MULTINODULAR AND NEOPLASTIC THYROID-TISSUE
    CALLICOTT, C
    GOODE, AW
    BRITISH JOURNAL OF SURGERY, 1995, 82 (10) : 1427 - 1428
  • [27] TISSUE-SPECIFICITY OF LOW-FIELD-STRENGTH MAGNETIZATION TRANSFER CONTRAST IMAGING
    NIEMI, PT
    KOMU, MES
    KOSKINEN, SK
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02): : 197 - 201
  • [29] Magnetization Transfer MRI Contrast May Correlate with Tissue Redox State in Prostate Cancer
    Tain, Rongwen
    Xu, He N.
    Zhou, Xiaohong J.
    Li, Lin Z.
    Cai, Kejia
    OXYGEN TRANSPORT TO TISSUE XXXVIII, 2016, 923 : 401 - 406
  • [30] Exploring the Use of Continuous RF Irradiation for Xenon Polarization Transfer Contrast Imaging
    Amzajerdian, F.
    Achekzai, T. S.
    Loza, L.
    Hamedani, H.
    Xin, Y.
    Duncan, I.
    Kadlecek, S.
    Ruppert, K.
    Rizi, R. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)