THE HOLDING STRENGTH OF CANNULATED SCREWS COMPARED WITH SOLID CORE SCREWS IN CORTICAL AND CANCELLOUS BONE

被引:33
|
作者
LEGGON, R [1 ]
LINDSEY, RW [1 ]
DOHERTY, BJ [1 ]
ALEXANDER, J [1 ]
NOBLE, P [1 ]
机构
[1] BAYLOR COLL MED,DEPT ORTHOPAED SURG,6550 FANNIN,SUITE 2625,HOUSTON,TX 77030
关键词
CANNULATED SCREW VERSUS SOLID CORE SCREW; CORTICAL BONE; CANCELLOUS BONE;
D O I
10.1097/00005131-199310000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The comparative holding strength of cannulated screws (CS) versus solid core screws (SCS) has not been reported, although differences exist in the respective diameters of their outer thread and pilot drill holes. Our objectives were to characterize these differences and determine the holding power of CS compared with SCS in cortical and cancellous bone. The dimensions of the Synthes (Paoli, PA) 3.5-mm SCS, 3.5-mm CS, 6.5-mm SCS, and 7.0-mm CS were measured, and the cross-sectional area for thread purchase was calculated. Using adult canine femurs, small-fragment 3.5-mm SCS were inserted in cortical (midshaft) and cancellous (condyle) bone of one limb, and CS were placed in similar locations in the contralateral limb. The same technique was used for large-fragment CS and SCS. Pull-out testing was performed using an MTS machine (MTS Systems, Minneapolis, MN) with axial loads applied at 5 mm/s, and data were analyzed to determine the effects of screw type, location, and size. Differences in CS versus SCS design result in higher cross-sectional areas available for SCS thread purchase. Yet no significant differences exists between screw types (SCS vs. CS) in either cortical or cancellous bone. In cancellous bone, large-fragment screws required more force to pull out than did small screws (p = 0.000). The mean force required to pull out small-fragment screws was higher in cortical bone than in cancellous bone (p = 0.000). These data suggest that the clinical decision to use CS versus SCS should not be based on pull-out strength.
引用
收藏
页码:450 / 457
页数:8
相关论文
共 50 条
  • [21] Holding strength of screws in plywood and oriented strandboard
    Erdil, YZ
    Zhang, J
    Eckelman, CA
    FOREST PRODUCTS JOURNAL, 2002, 52 (06) : 55 - 62
  • [22] The Functional and Radiological Outcome of Hoffa's Fracture Treated With Cannulated Cancellous Screws
    Kurahatti, Ajay
    Seenappa, Hariprasad
    Shanthappa, Arun H.
    Nagakumar, J. S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)
  • [23] Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling
    Lih-Huei Chen
    Ching-Lung Tai
    De-Mei Lee
    Po-Liang Lai
    Yen-Chen Lee
    Chi-Chien Niu
    Wen-Jer Chen
    BMC Musculoskeletal Disorders, 12
  • [24] Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling
    Chen, Lih-Huei
    Tai, Ching-Lung
    Lee, De-Mei
    Lai, Po-Liang
    Lee, Yen-Chen
    Niu, Chi-Chien
    Chen, Wen-Jer
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12
  • [25] Actual holding power of various screws in bone
    Lyon, WF
    Cochran, JR
    Smith, L
    ANNALS OF SURGERY, 1941, 114 (03) : 376 - 384
  • [26] Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone
    Lee, Jae Hyup
    Nam, Hwa
    Ryu, Hyun-Seung
    Seo, Jun-Hyuk
    Chang, Bong-Soon
    Lee, Choon-Ki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (03) : 291 - 297
  • [27] EFFECT OF MOVEMENT ON HOLDING POWER OF SCREWS IN BONE
    SCHATZKER, J
    HORNE, JG
    SUMNERSMITH, G
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1975, (111) : 257 - 262
  • [28] The reinforcement of cancellous bone screws with calcium phosphate cement
    Mermelstein, LE
    Chow, LC
    Friedman, C
    Crisco, JJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (01) : 15 - 20
  • [29] FATIGUE FAILURE OF CORTICAL BONE SCREWS
    ZAND, MS
    GOLDSTEIN, SA
    MATTHEWS, LS
    JOURNAL OF BIOMECHANICS, 1983, 16 (05) : 305 - &
  • [30] Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation
    Stadelmann, Vincent A.
    Bretton, Elise
    Terrier, Alexandre
    Procter, Philip
    Pioletti, Dominique P.
    JOURNAL OF BIOMECHANICS, 2010, 43 (15) : 2869 - 2874