ERRORS IN QUANTITATIVE DYNAMIC 3-DIMENSIONAL KEYHOLE MR-IMAGING OF THE BREAST

被引:15
|
作者
PLEWES, DB
BISHOP, J
SOUTAR, I
COHEN, E
机构
[1] Department of Medical Biophysics, University of Toronto, Sunnybrook Health Science Centre, Toronto, Ontario, M4N 3M5
[2] Department of Radiology, Mount Sinal Hospital, Toronto, Ontario
来源
关键词
ARTIFACT; BREAST; MR; BREAST NEOPLASMS; CONTRAST ENHANCEMENT; GADOLINIUM; IMAGE PROCESSING; K-SPACE;
D O I
10.1002/jmri.1880050322
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional (3D) keyhole magnetic resonance (MR) imaging has been proposed as a means of providing dynamic monitoring of contrast agent uptake by breast lesions, with complete breast coverage and high spatial and temporal resolution. The 3D keyhole technique dynamically samples the central regions of k-space in both phase-encoding directions and provides high-frequency data from a precontrast acquisition. Errors due to data truncation with two-dimensional and 3D region-of-interest measurements are estimated from a numerical simulation of various implementations of the 3D keyhole technique. Errors were found to increase with increasing temporal resolution and reduced object size. Errors of 75% are possible for objects with a diameter approaching 1 pixel when a 3D keyhole implementation that samples 50% of phase-encoding data in each direction is used. Preliminary clinical images with this approach illustrate artifacts consistent with inadequate k-space sampling.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 50 条
  • [1] FINGERS - 3-DIMENSIONAL MR-IMAGING AND ANGIOGRAPHY WITH A LOCAL GRADIENT COIL
    BLACKBAND, SJ
    CHAKRABARTI, I
    GIBBS, P
    BUCKLEY, DL
    HORSMAN, A
    [J]. RADIOLOGY, 1994, 190 (03) : 895 - 899
  • [2] FLASE - 3-DIMENSIONAL, SHORT TR, SE MR-IMAGING PULSE SEQUENCE
    MA, J
    WEHRLI, FW
    [J]. RADIOLOGY, 1995, 197 : 389 - 389
  • [3] Dynamic MR-imaging with radial scanning, a post-acquisition keyhole approach
    Lethmate, R
    Wajer, FTAW
    Crémillieux, Y
    van Ormondt, D
    Graveron-Demilly, D
    [J]. EURASIP JOURNAL ON APPLIED SIGNAL PROCESSING, 2003, 2003 (05) : 405 - 412
  • [4] Dynamic MR-Imaging with Radial Scanning, a Post-Acquisition Keyhole Approach
    Ralf Lethmate
    Frank T. A. W. Wajer
    Yannick Crémillieux
    Dirk van Ormondt
    Danielle Graveron-Demilly
    [J]. EURASIP Journal on Advances in Signal Processing, 2003
  • [5] 3-DIMENSIONAL ANISOTROPY CONTRAST MR-IMAGING OF THE RAT NERVOUS-SYSTEM - MR HISTOLOGY
    NAKADA, T
    MATSUZAWA, H
    [J]. RADIOLOGY, 1995, 194 (02) : 628 - 628
  • [6] MR-IMAGING OF THE BREAST
    WEINREB, JC
    NEWSTEAD, G
    [J]. RADIOLOGY, 1995, 196 (03) : 593 - 610
  • [7] MR-IMAGING OF KNEE HYALINE CARTILAGE - EVALUATION OF 2-DIMENSIONAL AND 3-DIMENSIONAL SEQUENCES
    TERVONEN, O
    DIETZ, MJ
    CARMICHAEL, SW
    EHMAN, RL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 663 - 668
  • [8] FAT-SUPPRESSED 3-DIMENSIONAL MR IMAGING OF THE BREAST
    HARMS, SE
    FLAMIG, DP
    HESLEY, KL
    EVANS, WP
    CHEEK, JH
    PETERS, GN
    KNOX, SM
    SAVINO, DA
    NETTO, GJ
    WELLS, RB
    JONES, SE
    [J]. RADIOGRAPHICS, 1993, 13 (02) : 247 - 267
  • [9] 3-DIMENSIONAL MR-IMAGING ANATOMY OF WHITE-MATTER TRACTS - ANATOMY AND PATHOLOGY
    KASAI, K
    MURAYAMA, N
    LEVRIER, O
    BRYAN, N
    SALAMON, G
    [J]. RADIOLOGY, 1995, 197 : 483 - 483
  • [10] 3-DIMENSIONAL MR-IMAGING OF THE CORONARY-ARTERIES - PRELIMINARY CLINICAL-EXPERIENCE
    PASCHAL, CB
    HAACKE, EM
    ADLER, LP
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03): : 491 - 500