INFLUENCE OF DETECTOR SIZE IN PHOTON-BEAM PROFILE MEASUREMENTS

被引:72
|
作者
SIBATA, CH [1 ]
MOTA, HC [1 ]
BEDDAR, AS [1 ]
HIGGINS, PD [1 ]
SHIN, KH [1 ]
机构
[1] CLEVELAND CLIN FDN,DEPT RADIAT THERAPY,CLEVELAND,OH 44195
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1991年 / 36卷 / 05期
关键词
D O I
10.1088/0031-9155/36/5/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Correction is necessary to account for the detector size in clinical dosimetry of photon and electron beams. This correction is due to the absorbed dose gradient present in a finite-size detector. Further corrections are necessary when the detector and phantom materials are not the same. These corrections are due to the perturbation in the charged-particle fluence. Generally these corrections are applied to measurements along the central axis of the beam. Cross beam profile measurements, however, are not usually corrected for detector size. The ionization profile is also usually assumed to be equivalent to the absorbed dose profile. We have corrected the ionization chamber size effect by two approaches: extrapolation of measurements to zero detector size and deconvolution of measurements using a simple model for the detector response function. We have measured absorbed dose profiles to water using a small water-equivalent plastic scintillation detector. Film profile measurements were also studied. The ionization profile corrected for detector size and absorbed dose profile were not equal, probably due to loss of charged-particle equilibrium in the beam edges. Forionization chamber measurements, knowledge of the charged-particle spectrum is needed to convert ionization to absorbed dose to water. This is not necessary for relative absorbed dose measurements under charged-particle equilibrium. Film has been shown to be a straightforward and reliable method for cross beam profile measurements.
引用
收藏
页码:621 / 631
页数:11
相关论文
共 50 条
  • [1] EVALUATION OF THE DOSIMETRIC CHARACTERISTICS OF A DIAMOND DETECTOR FOR PHOTON-BEAM MEASUREMENTS
    RUSTGI, SN
    [J]. MEDICAL PHYSICS, 1995, 22 (05) : 567 - 570
  • [2] BEAM PROFILE MONITORS FOR A TAGGED PHOTON-BEAM FACILITY
    ARENDS, J
    BREUER, M
    DAHMEN, HD
    DETEMPLE, P
    SCHNEIDER, W
    URBAN, D
    ZUCHT, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 306 (1-2): : 89 - 92
  • [3] The influence of detector size relative to field size in small-field photon-beam dosimetry using synthetic diamond crystals as sensors
    Ade, N.
    Nam, T. L.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2015, 113 : 6 - 13
  • [4] A NEW DESCRIPTION OF THE PHOTON-BEAM PEAK-DEPTH PROFILE AS A FUNCTION OF FIELD SIZE
    VANDEGEIJN, J
    MILLER, RW
    [J]. MEDICAL PHYSICS, 1986, 13 (06) : 904 - 909
  • [5] PHOTON-BEAM QUALITY SPECIFICATION BY NARROW-BEAM TRANSMISSION MEASUREMENTS
    NYSTROM, H
    KARLSSON, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08): : 1231 - 1245
  • [6] A NEW DESCRIPTION OF THE PHOTON-BEAM PEAK-DEPTH DOSE PROFILE AS A FUNCTION OF FIELD SIZE
    VANDEGEIJN, J
    MILLER, RW
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 506 - 506
  • [7] Development of a high-intensity photon-beam profile monitor
    Ishikawa, Takatsugu
    Fujimura, Hisako
    Hashimoto, Ryo
    Honda, Yuki
    Ishida, Takasln
    Kanda, Hiroki
    Kido, Satoshi
    Matsumura, Yuji
    Mryabe, Manabu
    Nagasawa, Ikuro
    Nanbu, Ken'ichi
    Shimizu, Hajime
    Suzuki, Koutaku
    Takahashi, Ken
    Tokiyasu, Atsushi O.
    Tsuchikawa, Yusuke
    Yamazaki, Hirohito
    [J]. 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016, 2017, 2017-January
  • [8] Development of a high-intensity photon-beam profile monitor
    Ishikawa, Takatsugu
    Fujimura, Hisako
    Hashimoto, Ryo
    Honda, Yuki
    Ishida, Takashi
    Kanda, Hiroki
    Kido, Satoshi
    Matsumura, Yuji
    Miyabe, Manabu
    Nagasawa, Ikuro
    Nanbu, Ken'ichi
    Shimizu, Hajime
    Suzuki, Koutaku
    Takahashi, Ken
    Tokiyasu, Atsushi O.
    Tsuchikawa, Yusuke
    Yamazaki, Hirohito
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [9] Experimental determination of the effect of detector size on profile measurements in narrow photon beams
    Pappas, E.
    Maris, T. G.
    Papadakis, A.
    Zacharopoulou, F.
    Damilakis, J.
    Papanikolaou, N.
    Gourtsoyiannis, N.
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3700 - 3710
  • [10] PHOTON-BEAM POSITION MONITOR
    IZUMI, T
    NAKAJIMA, T
    KURIHAMA, T
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1951 - 1952