Monte Carlo characterization of the GammaMed HDR Plus Ir-192 brachytherapy source

被引:0
|
作者
Reyes, E. [1 ]
Sosa, M. [1 ]
Gil-Villegas, A. [1 ]
Monzon, E. [2 ]
机构
[1] Univ Guanajuato, Div Ciencias & Ingn, Leon 37150, Gto, Mexico
[2] Inst Mexicano Seguro Social, Unidad Alta Especialidad 1, Leon 37320, Gto, Mexico
来源
关键词
brachytherapy source; Monte Carlo; iridium-192; high dose rate; dosimetric quantities;
D O I
10.1088/2057-1976/2/1/015017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to obtain the dose rate distribution in liquid water media for the GammaMed high dose rate (HDR) Plus Ir-192 source provided by Varian Medical Systems for their remote afterloading devices. The MCNP4C 3Monte Carlo code was used to simulate the dosimetry of GammaMed HDR Plus iridium-192 brachytherapy source in both air/vacuum and water environments. Dosimetry data in water was calculated and presented in an away-along table. All dosimetric quantities recommended by the American Association of Physicists in Medicine (AAPM) task group 43 report have been also calculated. These quantities are air kerma strength, dose rate constant, radial dose function and anisotropy function. The obtained results were compared with the consensus values determined by the AAPM from published data for this source, finding results in good agreement with them. The data presented in this study both complements previously published data and expands upon it through the use of a unique calculation methodology, involving a higher spatial resolution, conforming to the most recent recommendations by the AAPM and ESTRO physics committee. The results will be used as input to a TPS and as benchmark data to verify the results of treatment plans and for comparison with other datasets from this source.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Monte Carlo study of a bunker used for HDR Ir-192 brachytherapy
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Puchades, V
    Casal, E
    Crispin, V
    Cases, R
    Agramunt, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S242 - S242
  • [2] Monte Carlo calculated dose distribution for endovascular HDR brachytherapy with Ir-192
    Dries, WJF
    [J]. RADIOTHERAPY AND ONCOLOGY, 1997, 45 (01) : 77 - 82
  • [3] Monte Carlo dosimetry study of the flexisource IR-192 HDR source
    Casal, E.
    Granero, D.
    Perez-Calatayud, J.
    Ballester, F.
    Venselaar, J.
    Cases, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S267 - S267
  • [4] Monte Carlo dosimetric study of the flexisource IR-192 HDR source
    Casal, E.
    Perez-Calatayud, J.
    Granero, D.
    Ballester, F.
    Cases, R.
    Venselaar, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2122 - 2122
  • [5] Comparative dosimetry of GammaMed Plus high-dose rate Ir-192 brachytherapy source
    Patel, N. P.
    Majumdar, B.
    Vijayan, V.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2010, 35 (03) : 137 - 143
  • [6] A DOSIMETRIC STUDY OF THE MICROSELECTRON HDR IR-192 BRACHYTHERAPY SOURCE
    Granero, D.
    Rivard, M.
    Ballester, F.
    Perez-Calatayud, J.
    Vijande, J.
    Otal, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S479 - S479
  • [7] A Dosimetric Study of the MicroSelectron HDR Ir-192 Brachytherapy Source
    Granero, D.
    Rivard, M. J.
    Ballester, F.
    Perez-Calatayud, J.
    Vijande, J.
    Otal, A.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [8] A Monte Carlo study on dose distribution evaluation of Flexisource Ir-192 brachytherapy source
    Alizadeh, Majid
    Ghorbani, Mandi
    Haghparast, Abbas
    Zare, Naser
    Moghaddas, Toktam Ahmadi
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (03) : 204 - 209
  • [9] Healthy Tissue Dose Modeling Using Monte Carlo Methods for HDR Ir-192 Breast Brachytherapy Applicators
    Yang, Y.
    Zhang, Y.
    Rivard, M.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Design Optimization of a HDR Ir-192 Brachytherapy Skin Applicator Using Monte Carlo-Based Dosimetry
    Yang, Y.
    Rivard, M. J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3612 - 3612