AMBULATORY BLOOD-PRESSURE MONITORING

被引:8
|
作者
DUGGAN, J [1 ]
机构
[1] BEAUMONT HOSP,BLOOD PRESSURE UNIT,DUBLIN 9,IRELAND
关键词
BLOOD PRESSURE; BLOOD PRESSURE MONITORS; HYPERTENSION; END ORGAN DAMAGE; DRUG THERAPY;
D O I
10.1016/0163-7258(94)90028-0
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Non-invasive measurement of blood pressure in ambulatory humans began in the 1960s. Ambulatory devices have been modified over the years and are now pocket-sized, with almost noiseless pumps. Their accuracy must be validated by independent laboratories using a standardised protocol. Twenty-four-hour ambulatory monitoring offers considerable advantages over conventional measurement, including avoidance of error associated with conventional measurement, elimination of white-coat effect and the provision of a series of blood pressure readings over the time period rather than a one-off measurement. In clinical practice, 24-hr monitoring provides valuable assistance in both the diagnosis and treatment of hypertension, in particular, in the selection of drug and dosage regimen. In the research setting, 24-hr monitoring plays an important role in establishing dose-response relationships and the duration of action of new drugs. It also has a role in the design of antihypertensive trials by ensuring that those with white-coat hypertension are excluded and by reducing the number of subjects necessary for recruitment. Although 24-hr ambulatory blood pressure is a better predictor of target organ damage, definitive evidence as to whether it is a better predictor of prognosis in hypertension awaits the results of longitudinal studies, which are now underway.
引用
收藏
页码:313 / 321
页数:9
相关论文
共 50 条
  • [31] Ambulatory blood-pressure monitoring has arrived
    Lawrence R. Krakoff
    [J]. Nature Reviews Cardiology, 2011, 8 : 671 - 672
  • [32] CLINICAL USEFULNESS OF AMBULATORY BLOOD-PRESSURE MONITORING
    WHITE, WB
    GRIN, JM
    MCCABE, EJ
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1993, 6 (06) : S225 - S228
  • [33] AMBULATORY BLOOD-PRESSURE MONITORING - QUALITY ASSURANCE
    SHEPS, SG
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1995, 155 (05) : 548 - 548
  • [34] AMBULATORY BLOOD-PRESSURE MONITORING IN HEALTHY SCHOOLCHILDREN
    REICHERT, H
    LINDINGER, A
    FREY, O
    MORTZECK, J
    KIEFER, J
    BUSCH, C
    HOFFMANN, W
    [J]. PEDIATRIC NEPHROLOGY, 1995, 9 (03) : 282 - 286
  • [35] AMBULATORY BLOOD-PRESSURE MONITORING IN EVALUATION OF HYPERTENSION
    GARRETT, BN
    [J]. CLINICAL RESEARCH, 1981, 29 (02): : A357 - A357
  • [36] AMBULATORY BLOOD-PRESSURE MONITORING IN NORMOTENSIVE CHILDREN
    LURBE, E
    REDON, J
    LIAO, YL
    TACONS, J
    COOPER, RS
    ALVAREZ, V
    [J]. JOURNAL OF HYPERTENSION, 1994, 12 (12) : 1417 - 1423
  • [37] STATISTICAL CONSIDERATIONS IN AMBULATORY BLOOD-PRESSURE MONITORING
    PHILLIPS, RA
    THORNTON, J
    KRAKOFF, LR
    [J]. CLINICAL RESEARCH, 1987, 35 (03): : A358 - A358
  • [38] PROGNOSTIC VALUE OF AMBULATORY BLOOD-PRESSURE MONITORING
    CLEMENT, DL
    DEBUYZERE, M
    DUPREZ, D
    [J]. JOURNAL OF HYPERTENSION, 1994, 12 (08) : 857 - 864
  • [39] CLINICAL USES OF AMBULATORY BLOOD-PRESSURE MONITORING
    PORTMAN, RJ
    YETMAN, RJ
    [J]. PEDIATRIC NEPHROLOGY, 1994, 8 (03) : 367 - 376
  • [40] AMBULATORY BLOOD-PRESSURE MONITORING - WHEN IS IT WARRANTED
    THIBONNIER, M
    [J]. POSTGRADUATE MEDICINE, 1992, 91 (01) : 263 - &