QUANTITATIVE ESTIMATION OF HUMAN UTERINE ARTERY BLOOD-FLOW AND PELVIC BLOOD-FLOW REDISTRIBUTION IN PREGNANCY

被引:2
|
作者
PALMER, SK
ZAMUDIO, S
COFFIN, C
PARKER, S
STAMM, E
MOORE, LG
机构
[1] UNIV COLORADO,HLTH SCI CTR,DEPT RADIOL,DENVER,CO 80262
[2] UNIV COLORADO,HLTH SCI CTR,CARDIOVASC PULM RES LAB,DENVER,CO 80262
[3] UNIV COLORADO,DEPT ANTHROPOL,DENVER,CO 80202
来源
OBSTETRICS AND GYNECOLOGY | 1992年 / 80卷 / 06期
关键词
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine the contributions of uterine artery diameter and mean flow velocity to the increase in volumetric flow during human pregnancy. Methods: Volunteers (18 pregnant and six not pregnant) were studied using both a commercially available Doppler instrument with imaging ultrasound and an improved Doppler instrument with software that can determine instantaneous true mean blood flow velocity. Diameter and mean flow velocity measurements were combined to yield volumetric flows in the common iliac, external iliac, and uterine arteries during and after pregnancy. Results: Compared with the nonpregnant state, uterine artery diameter doubled by week 21 (from 1.4 +/- 0.1 to 2.8 +/- 0.2 mm; P < .05), did not change between weeks 21 and 30 (2.9 +/- 0.1 mm), and increased between weeks 30 and 36 (to 3.4 +/- 0.2 mm). Uterine artery mean flow velocity rose progressively from nonpregnant values to attain at week 36 a velocity nearly eight times faster (8.4 +/- 2.2 versus 61.4 +/- 3.0 cm/second; P < .05). Unilateral uterine artery blood flow at week 36 was 312 +/- 22 mL/minute. Conclusions: Compared with nonpregnant values, common iliac artery flow increased and external iliac artery flow decreased during pregnancy, suggesting that redistribution of pelvic flow to favor the uterus contributed to the pregnancy-associated rise in uterine artery flow. Early in pregnancy, the increase in uterine artery blood flow was due in equal parts to changes in uterine artery diameter and mean flow velocity, whereas late in pregnancy, the rise was due mainly to faster mean flow velocity.
引用
收藏
页码:1000 / 1006
页数:7
相关论文
共 50 条
  • [41] REDISTRIBUTION OF BLOOD-FLOW IN ACUTE HYPOMETABOLIC BEHAVIOR
    JEVNING, R
    WILSON, AF
    SMITH, WR
    MORTON, ME
    AMERICAN JOURNAL OF PHYSIOLOGY, 1978, 235 (01): : R89 - R92
  • [42] QUANTITATIVE ASSESSMENT OF HUMAN FETAL RENAL BLOOD-FLOW
    VEILLE, JC
    HANSON, RA
    TATUM, K
    KELLEY, K
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (06) : 1399 - 1402
  • [43] FETAL BLOOD-FLOW IN DIABETIC PREGNANCY
    OLOFSSON, P
    LINGMAN, G
    MARSAL, K
    SJOBERG, NO
    JOURNAL OF PERINATAL MEDICINE, 1987, 15 (06) : 545 - 553
  • [44] DOPPLER MEASUREMENTS OF CHANGES IN HUMAN MAMMARY AND UTERINE BLOOD-FLOW DURING PREGNANCY AND LACTATION
    THORESEN, M
    WESCHE, J
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1988, 67 (08) : 741 - 745
  • [45] CEREBRAL BLOOD-FLOW AND QUANTITATIVE RHEOENCEPHALOGRAPHY
    JACQUY, J
    DEKONINCK, WJ
    PIRAUX, A
    CALAY, R
    BACQ, J
    LEVY, D
    NOEL, G
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1974, 37 (05): : 507 - 511
  • [46] BLOOD-FLOW IN INTERNAL MAMMARY ARTERY
    BARNER, HB
    AMERICAN HEART JOURNAL, 1973, 86 (04) : 570 - 571
  • [47] QUANTITATIVE MEASUREMENT OF CEREBRAL BLOOD-FLOW
    HOUDART, R
    MAMO, H
    MERIC, P
    SEYLAZ, J
    ANNALES DE MEDECINE INTERNE, 1976, 127 (10): : 751 - 754
  • [48] TOTAL BLOOD-FLOW IN THE OPHTHALMIC ARTERY
    GRUENDLER, A
    MICHELSON, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 865 - 865
  • [49] BLOOD-FLOW
    NUBAR, Y
    BIORHEOLOGY, 1975, 12 (02) : 143 - 143
  • [50] BLOOD-FLOW
    SPILLER, P
    WEBBPEPLOE, MM
    EUROPEAN HEART JOURNAL, 1985, 6 : 11 - 18