Difference in ocular surface temperature by infrared thermography in phakic and pseudophakic patients

被引:18
|
作者
Sniegowski, Matthew [1 ]
Erlanger, Michael [1 ]
Velez-Montoya, Raul [1 ]
Olson, Jeffrey L. [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Ophthalmol, Rocky Mt Lions Eye Inst, 1675 Aurora Court, Aurora, CO 80045 USA
来源
CLINICAL OPHTHALMOLOGY | 2015年 / 9卷
关键词
digital thermal scans; intraocular lens implantation; cataract extraction;
D O I
10.2147/OPTH.S69670
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the change in ocular surface temperature between healthy phakic and pseudophakic patients. Methods: We included patients with no history of ocular disease other than cataract. Patients were divided into three groups: clear lens, cataract, and pseudophakic. All patients had two ocular surface digital thermal scans. An average of five surface points was used as the mean ocular surface temperature. Results were analyzed with a one-way analysis of variance and a Tukey's least significance difference test. The patients were further divided into phakic and pseudophakic groups. Correlation coefficients between several variables were done in order to assess dependencies. Results: Fifty-six eyes (28 cataracts, 12 clear lenses, 16 pseudophakic) were enrolled. The mean ocular surface temperature in the cataract group was 34.14 degrees C +/- 1.51 degrees C; clear lens: 34.43 degrees C +/- 2.27 degrees C; and pseudophakic: 34.97 degrees C +/- 1.57 degrees C. There were no statistical differences among the study groups (P=0.3). There was a nonsignificant negative correlation trend between age and surface temperature in the phakic group. The trend inverted in the pseudophakic group but without statistical significance. Conclusion: Although cataract extraction and intraocular lens implantation seem to induce a mild increase in ocular surface temperature, the effect is not clear and not significant.
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [31] Infrared ocular thermography in dogs with and without keratoconjunctivitis sicca
    Biondi, Flavia
    Dornbusch, Peterson T.
    Sampaio, Manuella
    Montiani-Ferreira, Fabiano
    [J]. VETERINARY OPHTHALMOLOGY, 2015, 18 (01) : 28 - 34
  • [32] Is there a difference in IOP control following GDD between primary and secondary glaucomas and phakic vs pseudophakic eyes?
    Phuong Nguyen
    Rosenberg, Nicole
    Meyer, Alissa
    Sherwood, Mark
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [33] Infrared thermographic investigation on the ocular surface temperature of normal subjects
    Matteoli, Sara
    Vannetti, Federica
    Sodi, Andrea
    Corvi, Andrea
    [J]. PHYSIOLOGICAL MEASUREMENT, 2020, 41 (04)
  • [34] Are binocular alignment and convergence amplitude different between phakic and pseudophakic older patients?
    Hashemi, Hassan
    Khabazkhoob, Mehdi
    Asharlous, Amir
    Hashemi, Alireza
    [J]. STRABISMUS, 2022, 30 (04) : 190 - 195
  • [35] New Endoscopic Surgical Approach for Anterior Hyaloid Dissection in Phakic and Pseudophakic Patients
    Kam, Yong W.
    Funk, Robert O.
    Barnard, Luke
    Ajlan, Radwan S.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 129 - 132
  • [36] Die temperature study by infrared thermography
    Hao, SW
    Hu, BH
    Niu, XP
    [J]. DIE CASTING ENGINEER, 1998, 42 (02): : 62 - 66
  • [37] Reliability of Infrared Thermography Images in the Analysis of the Plantar Surface Temperature in Diabetes Mellitus
    Silva, Natalia C. M.
    Castro, Hirlaine A.
    Carvalho, Leonardo C.
    Chaves, Erika C. L.
    Ruela, Ludmila O.
    Iunes, Denise H.
    [J]. JOURNAL OF CHIROPRACTIC MEDICINE, 2018, 17 (01) : 30 - 35
  • [38] Environmental factors affecting measurement of bovine scrotal surface temperature with infrared thermography
    Kastelic, JP
    Cook, RB
    Coulter, GH
    Wallins, GL
    Entz, T
    [J]. ANIMAL REPRODUCTION SCIENCE, 1996, 41 (3-4) : 153 - 159
  • [39] Reference Standards for Digital Infrared Thermography Measuring Surface Temperature of the Upper Limbs
    Son, Seong
    Yoo, Byung Rhae
    Zhang, Ho Yeol
    [J]. BIOENGINEERING-BASEL, 2023, 10 (06):
  • [40] Estimation of radiant temperature and emissivity of automobile's surface using infrared thermography
    Iino, A
    Tsukamoto, K
    Kusakabe, M
    [J]. SICE 2003 ANNUAL CONFERENCE, VOLS 1-3, 2003, : 441 - 446