Accuracy of computerized and conventional impression-making procedures for multiple straight and tilted dental implants

被引:0
|
作者
Gintaute, Aiste [1 ]
Papatrlantafyllou, Nlkolaos [1 ]
Aljehani, Meshaal [1 ]
Att, Wael [2 ]
机构
[1] Univ Freiburg, Sch Dent, Dept Prosthodont, Freiburg, Germany
[2] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
来源
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the accuracy of implant impressions using computer aided impression-making technology and a conventional approach in a standardized setting in vitro, and to verify the effect of implant angulation (40 to 45 degrees) on the accuracy of digital and conventional impression-making procedures. Materials and methods: Four different edentulous mandibular reference models (RMs) were manufactured. Two straight (RM1); four straight (RM2); two straight and two tilted (RM3); and six straight (RM4) dental implants were placed, simulating four different clinical scenarios. The computer-aided impressions (n = 5 for each RM) were made using an intraoral scanner (I0S) (True Definition, 3M ESPE). Polyether (n = 5 for each RM) and vinyl polysiloxane (n = 5 for each RM) impression materials were utilized for the conventional approach. The collected data were analyzed in terms of trueness. The statistical analysis was performed using one-way analysis of variance (ANOVA). Results: The overall differences of inter implant distance, identified in mean values, were statistically significant among the different impression-making groups in RM1, RM3, and RM4. The data analyses of overall interimplant angle deviations yielded statistically significant differences in all four RMs. However, the deviations obtained with both impression-making approaches did not exceed an interimplant distance threshold of 100 mu m, and an interimplant angle of 0.5 degrees, which seems to be clinically acceptable. Conclusion: Within the limits of this in vitro study, the accuracy of the computer-aided and conventional impression making approaches for straight and tilted dental implants was comparable, and might be clinically considered for full-arch, multiple-implant restorations. However, further clinical studies are required to verify the feasibility of different 10Ss (with and without scanning powder application), different implant systems, and multiple implant configurations.
引用
收藏
页码:550 / 565
页数:16
相关论文
共 42 条
  • [1] Comparative Evaluation of Impression Accuracy of Tilted and Straight Implants in All-on-Four Technique
    Ehsani, Sara
    Siadat, Hakimeh
    Alikhasi, Marzieh
    [J]. IMPLANT DENTISTRY, 2014, 23 (02) : 225 - 230
  • [2] Accuracy of impression-making methods in edentulous arches: An in vitro study encompassing conventional and digital methods
    Li, Jiayi
    Moon, Hong Seok
    Kim, Jee-Hwan
    Yoon, Hyung-In
    Oh, Kyung Chul
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 479 - 486
  • [3] Comparison of the accuracy of different impression procedures in case of multiple and angulated implants Accuracy of impressions in multiple and angulated implants
    Richi, M. Wafa
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    [J]. HEAD & FACE MEDICINE, 2020, 16 (01)
  • [4] Accuracy of digital impression in dental implants: A literature review
    Kulivand, Sudabe
    Moslemion, Maryam
    [J]. INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 2093 - 2100
  • [5] Comparison of the accuracy of different impression procedures in case of multiple and angulated implantsAccuracy of impressions in multiple and angulated implants
    M. Wafa Richi
    Sevcan Kurtulmus-Yilmaz
    Oguz Ozan
    [J]. Head & Face Medicine, 16
  • [6] Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies
    Albanchez-Gonzalez, Maria Isabel
    Brinkmann, Jorge Cortes-Breton
    Pelaez-Rico, Jesus
    Lopez-Suarez, Carlos
    Rodriguez-Alonso, Veronica
    Suarez-Garcia, Maria Jesus
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (04)
  • [7] Dimensional accuracy of vinyl polyetherand polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants
    Rajendran, Rohini
    Chander, N. Gopi
    Anitha, Kuttae Vishwanathan
    Muthukumar, Balasubramanian
    [J]. EUROPEAN ORAL RESEARCH, 2021, 55 (02) : 54 - 59
  • [8] ACCURACY OF A SELF-PERFORATING IMPRESSION TRAY FOR DENTAL IMPLANTS
    Marotti, Juliana
    Tortamano, Pedro
    Castilho, Tatiana R. R. N.
    Steagall, Washington, Jr.
    Wolfart, Stefan
    Haselhuhn, Klaus
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (04): : 843 - 848
  • [9] Polygonal Area of Prosthesis Support with Straight and Tilted Dental Implants in Edentulous Maxillae
    Wentaschek, Stefan
    Lehmann, Karl Martin
    Scheller, Herbert
    Weibrich, Gernot
    Behneke, Nikolaus
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (03) : 245 - 252
  • [10] Can we measure patients' perception during dental impressions? The Burdens in Dental Impression-Making Questionnaire - BiDIM-Q
    Tsirogiannis, Panagiotis
    Neophytou, Sophia
    Reul, Anika
    Heydecke, Guido
    Reissmann, Daniel R.
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2017, 61 (01) : 34 - 42