CONE-BEAM TRANSMISSION COMPUTED-TOMOGRAPHY FOR NONUNIFORM ATTENUATION COMPENSATION OF SPECT IMAGES

被引:0
|
作者
MANGLOS, SH
BASSANO, DA
THOMAS, FD
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper develops and tests cone-beam transmission computed tomography (CB-CT) for attenuation compensation of SPECT images. CB-CT was implemented on a rotating gamma camera with a point source (1-2 mCi) of Tc-99m, and a light-weight aluminium source holder. A cone-beam collimator may be used but is not required. Since the point source is either located at the collimator focal point, or the camera is uncollimated, CB-CT has excellent sensitivity (at least 150 times that of a parallel-hole, high-resolution collimator). The predicted resolution is equal to the intrinsic gamma camera resolution (3-4 mm), which is much higher than for a high-resolution, parallel-hole collimator (10-20 mm). In the present study, CB-CT provided low noise, high-resolution attenuation maps for use in a nonuniform attenuation-weighted backprojection algorithm. The attenuation compensation accuracy was tested using basic geometries of line sources and nonuniform density models. For the appropriate scaling of the attenuation map, the attenuation compensation was accurate and removed the SPECT image distortion associated with nonuniform attenuation. Attenuation maps acquired either with cone beam collimator or without any collimator were both successful. Using CB-CT, SPECT can thus be made much more accurate without adding unduly to the imaging time, complexity, or cost.
引用
收藏
页码:1813 / 1820
页数:8
相关论文
共 50 条
  • [21] Asymmetric cone-beam transmission tomography
    Zeng, GSL
    Gullberg, GT
    Christian, PE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 117 - 124
  • [22] NONUNIFORM ATTENUATION IN COMPUTED-TOMOGRAPHY STUDY OF THE CIRRHOTIC LIVER
    MULHERN, CB
    ARGER, PH
    COLEMAN, BG
    STEIN, GN
    RADIOLOGY, 1979, 132 (02) : 399 - 402
  • [23] Spect nonuniform attenuation compensation using transmission CT attenuation maps
    Jaszczak, RJ
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 : SH503 - SH503
  • [24] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [25] Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images
    da Fonte, Juliana B. Melo
    Fontenele, Rocharles Cavalcante
    Freitas, Deborah Queiroz
    IMAGING SCIENCE IN DENTISTRY, 2024,
  • [26] A PRACTICAL ATTENUATION COMPENSATION METHOD FOR CONE BEAM SPECT
    MANGLOS, SH
    JASZCZAK, RJ
    FLOYD, CE
    GREER, KL
    COLEMAN, RE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 294 - 299
  • [28] ATTENUATION COMPENSATION OF CONE BEAM SPECT IMAGES USING MAXIMUM-LIKELIHOOD RECONSTRUCTION
    MANGLOS, SH
    THOMAS, FD
    CAPONE, RB
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) : 66 - 73
  • [29] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [30] Simple ROI Cone-Beam Computed Tomography
    Maass, Clemens
    Knaup, Michael
    Sawall, Stefan
    Kachelriess, Marc
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3161 - 3168