Effects of Eccentric Impeller Position on Radial Passive Stability in a Magnetically Levitated Centrifugal Blood Pump with a Double Volute

被引:8
|
作者
Shida, Shuya [1 ,3 ]
Masuzawa, Toru [2 ]
Osa, Masahiro [2 ]
Sato, Ryota [1 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, Hitachi, Ibaraki, Japan
[2] Ibaraki Univ, Dept Mech Engn, Hitachi, Ibaraki, Japan
[3] 4-12-1 Nakanarusawa, Hitachi, Ibaraki 3168511, Japan
关键词
eccentric impeller position; double volute; magnetic suspension; hydraulic force; computational fluid dynamics (CFD);
D O I
10.14326/abe.7.63
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluation of the impeller radial stability is important from the bioengineering point of view in the development of mechanical circulatory support devices (MCSDs) for safer use as bridge for several months or destination therapy for years. In this study, radial stability of a magnetically levitated impeller in a centrifugal blood pump with an axially magnetic suspension system was evaluated by investigating the effects of the eccentric impeller position on passive stability, aiming to propose a pump design guide for the development and safer clinical use of MCSDs. First, impeller displacements in the prototype pump were measured using a mock loop together with laser displacement sensors. Then, the radial hydraulic forces exerted on an eccentric impeller were calculated using computational fluid dynamics (CFD) analysis for four volute-casing geometries. In addition, hemocompatibility was assessed using CFD calculations of scalar shear stress exerted on blood. Measurement of impeller displacement showed that the displacement varied from 0.56 to 0.27 mm at a rotational speed of 1800 rpm as the flow rate increased from 0 to 6.5 L/min. In the CFD calculation, the radial hydraulic force increased linearly from 0.2 to 1.7 N as the impeller displacement increased from 0 to 0.5 mm for all the double volute geometries, under conditions of a rotational speed of 1800 rpm and flow rates of 3, 5 and 7 L/min. These results indicate that the impeller stability in the prototype pump is acceptable at the operation conditions of ventricular assist devices, because the magnetic bearing stiffness of radial component was 4.1 N/mm. In the pressure recovery analysis of eccentric impellers, a double volute was not effective because of the unbalanced pressure field generated by the unbalanced pressure recovery. Thus, the increase in radial hydraulic force associated with an eccentric impeller could not be avoided by changing the conventional double volute design. The CFD analysis of geometrical variation indicated that widening of the radial clearance is an effective approach to improve the radial stability as well as hemocompatibility, although the radial clearance should be designed based on trade-offs among impeller stability, hemocompatibility and pump performance.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [41] Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems
    T Akamatsu
    T Tsukiya
    Sadhana, 1998, 23 : 597 - 603
  • [42] Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems
    Akamatsu, T
    Tsukiya, T
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 1998, 23 (5-6): : 597 - 603
  • [43] Effects of blade geometry on centrifugal blood pump impeller performance
    Chan, WK
    Ng, BTH
    Yu, SCM
    Chua, LP
    Wong, YW
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 583 - 584
  • [44] Numerical Investigation on the Mechanism of Double-Volute Balancing Radial Hydraulic Force on the Centrifugal Pump
    Yuan, Ye
    Yuan, Shouqi
    Tang, Lingdi
    PROCESSES, 2019, 7 (10)
  • [45] DETERMINISTIC INTERACTION BETWEEN THE IMPELLER FLOW AND BOTH THE INLET AND OUTLET VOLUTE TONGUES FOR A DOUBLE SUCTION CENTRIFUGAL PUMP
    Fernandez Oro, Jesus Manuel
    Argueelles Diaz, Katia Maria
    Gonzalez, Jose
    Guerras Colon, Israel
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE, VOL 1, PTS A-C, 2009, : 357 - 369
  • [46] Decomposition of Deterministic Unsteadiness in a Centrifugal Turbomachine: Nonlinear Interactions Between the Impeller Flow and Volute for a Double Suction Pump
    Fernandez Oro, Jesus Manuel
    Gonzalez, Jose
    Argueelles Diaz, Katia M.
    Guerras Colon, Francisco Israel
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (01):
  • [47] Numerical investigation on the effect of impeller axial position on hemodynamics of an extracorporeal centrifugal blood pump
    Lv, Shen
    He, Zhi-Peng
    Liu, Guang-Mao
    Hu, Sheng-Shou
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (13) : 1744 - 1755
  • [48] Serial Assessment of Magnetically Levitated Centrifugal-Flow LVAD Pump Position and Inflow Angle on Chest Radiograph and Effects on Adverse Events
    Butler, C.
    Naka, Y.
    Sanchez, J.
    Malick, A.
    Melehy, A.
    Kurlansky, P.
    Ning, Y.
    Nemeth, S.
    Topkara, V.
    Yuzefpolskaya, M.
    Colombo, P.
    Sayer, G.
    Uriel, N.
    Takayama, H.
    Takeda, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S412 - S412
  • [49] Investigation on impeller radial force for double-suction centrifugal pump with staggered blade arrangement
    Zhang, Z. C.
    Wang, F. J.
    Yao, Z. F.
    Leng, H. F.
    Zhou, P. J.
    6TH INTERNATIONAL CONFERENCE ON PUMPS AND FANS WITH COMPRESSORS AND WIND TURBINES (ICPF2013), 2013, 52
  • [50] Effects of gap between impeller and volute tongue on a pressure fluctuation in double-suction pump
    Jin, Jeong-Min
    Jung, Kuk Jin
    Kim, Yo-Hwan
    Kim, Youn-Jea
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (12) : 4897 - 4903