Effects of Eccentric Impeller Position on Radial Passive Stability in a Magnetically Levitated Centrifugal Blood Pump with a Double Volute

被引:8
|
作者
Shida, Shuya [1 ,3 ]
Masuzawa, Toru [2 ]
Osa, Masahiro [2 ]
Sato, Ryota [1 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, Hitachi, Ibaraki, Japan
[2] Ibaraki Univ, Dept Mech Engn, Hitachi, Ibaraki, Japan
[3] 4-12-1 Nakanarusawa, Hitachi, Ibaraki 3168511, Japan
来源
关键词
eccentric impeller position; double volute; magnetic suspension; hydraulic force; computational fluid dynamics (CFD);
D O I
10.14326/abe.7.63
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluation of the impeller radial stability is important from the bioengineering point of view in the development of mechanical circulatory support devices (MCSDs) for safer use as bridge for several months or destination therapy for years. In this study, radial stability of a magnetically levitated impeller in a centrifugal blood pump with an axially magnetic suspension system was evaluated by investigating the effects of the eccentric impeller position on passive stability, aiming to propose a pump design guide for the development and safer clinical use of MCSDs. First, impeller displacements in the prototype pump were measured using a mock loop together with laser displacement sensors. Then, the radial hydraulic forces exerted on an eccentric impeller were calculated using computational fluid dynamics (CFD) analysis for four volute-casing geometries. In addition, hemocompatibility was assessed using CFD calculations of scalar shear stress exerted on blood. Measurement of impeller displacement showed that the displacement varied from 0.56 to 0.27 mm at a rotational speed of 1800 rpm as the flow rate increased from 0 to 6.5 L/min. In the CFD calculation, the radial hydraulic force increased linearly from 0.2 to 1.7 N as the impeller displacement increased from 0 to 0.5 mm for all the double volute geometries, under conditions of a rotational speed of 1800 rpm and flow rates of 3, 5 and 7 L/min. These results indicate that the impeller stability in the prototype pump is acceptable at the operation conditions of ventricular assist devices, because the magnetic bearing stiffness of radial component was 4.1 N/mm. In the pressure recovery analysis of eccentric impellers, a double volute was not effective because of the unbalanced pressure field generated by the unbalanced pressure recovery. Thus, the increase in radial hydraulic force associated with an eccentric impeller could not be avoided by changing the conventional double volute design. The CFD analysis of geometrical variation indicated that widening of the radial clearance is an effective approach to improve the radial stability as well as hemocompatibility, although the radial clearance should be designed based on trade-offs among impeller stability, hemocompatibility and pump performance.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [41] Decomposition of Deterministic Unsteadiness in a Centrifugal Turbomachine: Nonlinear Interactions Between the Impeller Flow and Volute for a Double Suction Pump
    Fernandez Oro, Jesus Manuel
    Gonzalez, Jose
    Argueelles Diaz, Katia M.
    Guerras Colon, Francisco Israel
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (01):
  • [42] Numerical investigation on the effect of impeller axial position on hemodynamics of an extracorporeal centrifugal blood pump
    Lv, Shen
    He, Zhi-Peng
    Liu, Guang-Mao
    Hu, Sheng-Shou
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (13) : 1744 - 1755
  • [43] Investigation on impeller radial force for double-suction centrifugal pump with staggered blade arrangement
    Zhang, Z. C.
    Wang, F. J.
    Yao, Z. F.
    Leng, H. F.
    Zhou, P. J.
    [J]. 6TH INTERNATIONAL CONFERENCE ON PUMPS AND FANS WITH COMPRESSORS AND WIND TURBINES (ICPF2013), 2013, 52
  • [44] Effects of gap between impeller and volute tongue on a pressure fluctuation in double-suction pump
    Jeong-Min Jin
    Kuk Jin Jung
    Yo-Hwan Kim
    Youn-Jea Kim
    [J]. Journal of Mechanical Science and Technology, 2020, 34 : 4897 - 4903
  • [45] Effects of gap between impeller and volute tongue on a pressure fluctuation in double-suction pump
    Jin, Jeong-Min
    Jung, Kuk Jin
    Kim, Yo-Hwan
    Kim, Youn-Jea
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (12) : 4897 - 4903
  • [46] Serial Assessment of Magnetically Levitated Centrifugal-Flow LVAD Pump Position and Inflow Angle on Chest Radiograph and Effects on Adverse Events
    Butler, C.
    Naka, Y.
    Sanchez, J.
    Malick, A.
    Melehy, A.
    Kurlansky, P.
    Ning, Y.
    Nemeth, S.
    Topkara, V.
    Yuzefpolskaya, M.
    Colombo, P.
    Sayer, G.
    Uriel, N.
    Takayama, H.
    Takeda, K.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S412 - S412
  • [47] Effect of a bearing gap on hemolytic property in a hydrodynamically levitated centrifugal blood pump with a semi-open impeller
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    Yambe, Tomoyuki
    Imachi, Kou
    Yamane, Takashi
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2013, 23 (1-2) : 37 - 47
  • [48] Effects of blade inlet edge position on pressure pulsation in volute of a single blade centrifugal pump
    Chen, Jianfang
    Shi, Weidong
    Zhang, Desheng
    Tan, Linwei
    [J]. Zhendong yu Chongji/Journal of Vibration and Shock, 2021, 40 (23): : 239 - 246
  • [49] Effects of the Radial Gap Between Impeller Tips and Volute Tongue Influencing the Performance and Pressure Pulsations of Pump as Turbine
    Yang, Sun-Sheng
    Liu, Hou-Lin
    Kong, Fan-Yu
    Xia, Bin
    Tan, Lin-Wei
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (05):
  • [50] Optimal Bearing Gap of a Multiarc Radial Bearing in a Hydrodynamically Levitated Centrifugal Blood Pump for the Reduction of Hemolysis
    Kosaka, Ryo
    Yasui, Kazuya
    Nishida, Masahiro
    Kawaguchi, Yasuo
    Maruyama, Osamu
    Yamane, Takashi
    [J]. ARTIFICIAL ORGANS, 2014, 38 (09) : 818 - 822