THE USE OF STABLE XENON-ENHANCED COMPUTED TOMOGRAPHIC STUDIES OF CEREBRAL BLOOD-FLOW TO DEFINE CHANGES IN CEREBRAL CARBON-DIOXIDE VASORESPONSIVITY CAUSED BY A SEVERE HEAD-INJURY

被引:78
|
作者
MARION, DW [1 ]
BOUMA, GJ [1 ]
机构
[1] VIRGINIA COMMONWEALTH UNIV,MED COLL VIRGINIA,DIV NEUROL SURG,RICHMOND,VA 23298
关键词
ACUTE HEAD INJURY; CO2; VASORESPONSIVITY; HYPERVENTILATION; INTRACRANIAL HYPERTENSION; REGIONAL BLOOD FLOW; XENON;
D O I
10.1227/00006123-199112000-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Previous studies using the xenon-133 cerebral blood flow (CBF) method have documented the impairment of CO2 vasoresponsivity after a severe head injury, but only global values can be obtained reliably with this technique. We studied CO2 vasoresponsivity using the stable xenon-enhanced computed tomographic CBF method, which provided information about well-defined cortical regions and deep brain structures not available with the xenon-133 method. In 17 patients with admission Glasgow Coma Scale scores of 8 or less, hemispheric CO2 vasoresponsivity ranged from 1.3 to 8.5% per mm Hg change in partial CO2 pressure. Lobar, cerebellar, basal ganglia, and brain stem CO2 vasoresponsivity frequently varied from the mean global value by more than 25%. In all but one patient, local CO2 vasoresponsivity in one or more of these areas differed from the mean global value by more than 50%. The greatest variability occurred in patients with acute subdural hematomas and diffuse (bihemispheric) injuries. This variability in CO2 vasoresponsivity has important implications for the effective and safe management of intracranial hypertension that frequently accompanies severe head injury.
引用
收藏
页码:869 / 873
页数:5
相关论文
共 50 条
  • [31] XENON ENHANCED DYNAMIC COMPUTED-TOMOGRAPHY - MULTILEVEL CEREBRAL BLOOD-FLOW STUDIES
    GUR, D
    YONAS, H
    HERBERT, D
    WOLFSON, SK
    KENNEDY, WH
    DRAYER, BP
    GRAY, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (03) : 334 - 340
  • [32] MAPPING OF LOCAL CEREBRAL BLOOD-FLOW WITH STABLE XENON-ENHANCED CT AND THE CURVE-FITTING METHOD OF ANALYSIS
    TOUHO, H
    KARASAWA, J
    NAKAGAWARA, J
    TAZAWA, T
    YAMADA, K
    KURIYAMA, Y
    ASAI, M
    KAGAWA, M
    KOBAYASHI, K
    YASUE, H
    RADIOLOGY, 1988, 168 (01) : 207 - 212
  • [33] THE EFFECT OF COMPUTED-TOMOGRAPHY NOISE AND TISSUE HETEROGENEITY ON CEREBRAL BLOOD-FLOW DETERMINATION BY XENON-ENHANCED COMPUTED-TOMOGRAPHY
    GOOD, WF
    GUR, D
    MEDICAL PHYSICS, 1987, 14 (04) : 557 - 561
  • [34] CEREBRAL BLOOD-FLOW MEASURED BY XENON-ENHANCED COMPUTED-TOMOGRAPHY AS A GUIDE TO MANAGEMENT OF PATIENTS WITH CEREBROVASCULAR-DISEASE
    WEBSTER, MW
    STEED, DL
    YONAS, H
    LATCHAW, RE
    WOLFSON, SK
    GUR, D
    JOURNAL OF VASCULAR SURGERY, 1986, 3 (02) : 298 - 304
  • [35] REGIONAL CEREBRAL BLOOD-FLOW AND CARBON-DIOXIDE REACTIVITY AFTER NONCEREBRAL INJURY IN THE RAT
    HADFIELD, JM
    YATES, DW
    KIRKMAN, E
    LITTLE, RA
    CIRCULATORY SHOCK, 1993, 39 (02) : 100 - 106
  • [37] CEREBRAL BLOOD-FLOW MAPPING USING STABLE XENON-ENHANCED CT IN SICKLE-CELL CEREBROVASCULAR-DISEASE
    NUMAGUCHI, Y
    HALLER, JS
    HUMBERT, JR
    ROBINSON, AE
    LINDSTROM, WW
    GRUENAUER, LM
    CAREY, JE
    NEURORADIOLOGY, 1990, 32 (04) : 289 - 295
  • [38] THE ROLE OF NOISE IN THE MEASUREMENT OF CEREBRAL BLOOD-FLOW AND PARTITION-COEFFICIENT USING XENON-ENHANCED COMPUTED-TOMOGRAPHY
    BEWS, J
    DUNSCOMBE, PB
    LEE, TY
    MCCLARTY, B
    KROEKER, MA
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07): : 937 - 945
  • [39] CLINICAL-EXPERIENCE WITH THE USE OF XENON-ENHANCED CT BLOOD-FLOW MAPPING IN CEREBRAL VASCULAR-DISEASE
    YONAS, H
    WOLFSON, SK
    GUR, D
    LATCHAW, RE
    GOOD, WF
    LEANZA, R
    JACKSON, DL
    JANNETTA, PJ
    REINMUTH, OM
    STROKE, 1984, 15 (03) : 443 - 450
  • [40] ACUTE REGIONAL CEREBRAL BLOOD-FLOW CHANGES CAUSED BY SEVERE HEAD-INJURIES
    MARION, DW
    DARBY, J
    YONAS, H
    JOURNAL OF NEUROSURGERY, 1991, 74 (03) : 407 - 414