Sonographic parameters for diagnosing fetal head engagement during labour

被引:8
|
作者
Wiafe, Yaw A. [1 ,2 ]
Whitehead, Bill [1 ]
Venables, Heather [1 ]
Odoi, Alexander T. [3 ,4 ]
机构
[1] Univ Derby, Dept Nursing Radiog & Healthcare, Derby, England
[2] Kwame Nkrumah Univ Sci & Technol, Fac Allied Hlth Sci, Dept Sonog, Kumasi, Ghana
[3] Kwame Nkrumah Univ Sci & Technol, Dept Obstet & Gynaecol, Sch Med Sci, Kumasi, Ghana
[4] Komfo Anokye Teaching Hosp, Kumasi, Ghana
关键词
Angle of progression; head-perineum distance; head-symphysis distance; engaged fetal head;
D O I
10.1177/1742271X18755080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the diagnostic performance of the head-perineum distance, angle of progression, and the head-symphysis distance as intrapartum ultrasound parameters in the determination of an engaged fetal head. Two hundred and one women in labour underwent both ultrasound and digital vaginal examination in the estimation of fetal head station. The transperineal ultrasound measured head-perineum distance, angle of progression, and head-symphysis distance for values correlating with digital vaginal examination head station. Using station 0 as the minimum level of head engagement, correlating cut-off values for head-perineum distance, angle of progression, and head-symphysis distance were obtained. Receiver operating characteristics were used in determining the diagnostic performance of these cut-off values for the detection of fetal head engagement. With head-perineum distance of 3.6 cm the sensitivity and specificity of sonographic determination of engaged fetal head were 78.7 and 72.3%, respectively. A head-symphysis distance of 2.8 cm also had sensitivity and specificity of 74.5 and 70.8%, respectively, in determining engagement, whilst an angle of progression of 101 degrees was consistent with engagement by digital vaginal examination with 68.1% sensitivity and 68.2% specificity. Ultrasound shows high diagnostic performance in determining engaged fetal head at a head-perineum distance of <= 3.6 cm, head-symphysis distance of <= 2.8 cm, and angle of progression of >= 101 degrees.
引用
收藏
页码:16 / 21
页数:6
相关论文
共 50 条
  • [21] Performance of an algorithm for diagnosing acute cholecystitis using clinical and sonographic parameters
    Patel, Maitray D.
    Sill, Andrew P.
    Dahiya, Nirvikar
    Chen, Frederick
    Eversman, William G.
    Kriegshauser, J. Scott
    Young, Scott W.
    ABDOMINAL RADIOLOGY, 2022, 47 (02) : 576 - 585
  • [22] Performance of an algorithm for diagnosing acute cholecystitis using clinical and sonographic parameters
    Maitray D. Patel
    Andrew P. Sill
    Nirvikar Dahiya
    Frederick Chen
    William G. Eversman
    J. Scott Kriegshauser
    Scott W. Young
    Abdominal Radiology, 2022, 47 : 576 - 585
  • [23] Fetal head moulding: finite element analysis of a fetal skull subjected to uterine pressures during the first stage of labour
    Lapeer, RJ
    Prager, RW
    JOURNAL OF BIOMECHANICS, 2001, 34 (09) : 1125 - 1133
  • [24] Correlation between clinical fetal head station and sonographic angle of progression during the second stage of labor
    Perlman, Sharon
    Kivilevitch, Zvi
    Moran, Orit
    Katorza, Eldad
    Kees, Salim
    Achiron, Reuven
    Gilboa, Yinon
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2018, 31 (21): : 2905 - 2910
  • [25] Fetal oxygen saturation during labour
    Chua, S
    Yeong, SM
    Razvi, K
    Arulkumaran, S
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (09): : 1080 - 1083
  • [27] The Potential Diagnostic Value of Sonographic Fetal Parameters as Markers of Prematurity
    Khoroushi, Farzaneh
    Toosi, Farrokh Seilanian
    Tizabi, Zahra Rastegar
    Nejad, Ehsan Hassan
    Mirzaeian, Sara
    Moradi, Ali
    Faramarzi, Raheleh
    Jarahi, Lida
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2024,
  • [28] Selection of Standards for Sonographic Fetal Head Circumference by Use of z -Scores
    Combs, C. Andrew
    del Rosario, Amber
    Balogun, Olaide Ashimi
    Bowman, Zachary S.
    Amara, Sushma
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e2625 - e2635
  • [29] Sonographic Estimation of the Fetal Head Circumference: Accuracy and Factors Affecting the Error
    Poojari, Vidyashree Ganesh
    Jose, Aiswarya
    Pai, Muralidhar, V
    JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2022, 72 (SUPPL 1): : 134 - 138
  • [30] Association between sonographic measurement of fetal head circumference and labor outcome
    Aviram, Amir
    Yogev, Yariv
    Bardin, Ron
    Hiersch, Liran
    Wiznitzer, Arnon
    Hadar, Eran
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2016, 132 (01) : 72 - 76