MYOCARDIAL PERFUSION IMAGING WITH TC-99M TETROFOSMIN - COMPARISON TO (TL)-T-201 IMAGING AND CORONARY ANGIOGRAPHY IN A PHASE-III MULTICENTER

被引:153
|
作者
ZARET, BL
RIGO, P
WACKERS, FJT
HENDEL, RC
BRAAT, SH
ISKANDRIAN, AS
SRIDHARA, BS
JAIN, D
ITTI, R
SERAFINI, AN
GORIS, ML
LAHIRI, A
HALDERS, S
KOPPEJANS, L
CAJOB, I
WILLEMS, P
BONTEMPS, L
EGROIZARD, P
SAYEGH, Y
FRAYSSE, M
BENOIT, TR
LELLERLO, B
FOULON, J
KLINE, R
MORRISSETTE, G
PRICE, L
JACKSON, R
SPIES, S
BELLOW, S
LEONARD, S
BULL, C
SRIDHARA, B
RAVAL, U
CRAWLEY, J
SMITH, T
ISKANDRIAN, A
HEO, J
UNTEEKER, W
FEINSMITH, N
CAVE, V
WASSERLEBEN, V
MCDOUGALL, R
BLAKE, L
GUREVICH, N
FUJII, C
EZUDDIN, S
SEQUEIRA, R
LOWERY, M
WACKERS, FJ
MATTERA, J
机构
关键词
TETROFOSMIN; IMAGING;
D O I
10.1161/01.CIR.91.2.313
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Our objective was to compare the sensitivity and specificity of tetrofosmin, a new Tc-99m-labeled myocardial perfusion imaging agent for the detection of myocardial perfusion abnormalities, with those of Tl-201 and coronary angiography. Our hypothesis was that same-day stress/rest tetrofosmin imaging could provide data comparable to those of Tl-201 imaging. Myocardial perfusion imaging plays an important role for the evaluation of coronary artery disease. Newer Tc-99m-labeled agents offer several advantages over Tl-201, the conventional myocardial perfusion imaging agent. Tetrofosmin is a new Tc-99m-labeled agent with promising results in preliminary studies. Methods and Results Two hundred fifty-two patients with suspected coronary artery disease were enrolled in 10 centers in the United States and Europe. All patients underwent exercise and rest myocardial perfusion imaging with Tc-99m-tetrofosmin using two separate injections of the radiotracer 4 hours apart on the same day. Planar images were obtained in three standard views 15 to 60 minutes after radiotracer injection. Patients also underwent standard exercise and redistribution planar Tl-201 imaging within 2 weeks of tetrofosmin imaging. In addition, 58 healthy subjects with low likelihood of coronary artery disease underwent exercise and rest tetrofosmin imaging. Coronary angiograms were available in 181 patients with suspected coronary artery disease. All radionuclide images were processed in the central core laboratory and interpreted blindly by a panel of four experienced readers. Tl-201 images and tetrofosmin images were read separately. Discrepancies were resolved by consensus. The workload, peak heart rate, and double products were comparable during exercise for both imaging agents. Technically acceptable paired Tl-201 and tetrofosmin images were available in 224 of 252 patients. Tetrofosmin images were generally of good quality, with low extracardiac activity, and easy to interpret. Patients were categorized as showing normal, ischemia, infarction, or mixture with each imaging modality. Precise concordance for each of these categories was 59.4% (kappa=0.44; 95% CI, 0.35 to 0.53). When patients were categorized as normal or abnormal, the concordance was 80.4% (kappa=0.55; 95% CI, 0.43 to 0.67). When each of five anatomic territories (septal, anterior, inferior, lateral, and apical) was categorized as normal versus abnormal, the concordance Varied from 81% to 90%. When similar comparison was made for the specific category of abnormality, the concordance was 64% to 84%. When coronary angiography was used as the criterion, the sensitivity and positive and negative predictive accuracy of tetrofosmin and Tl-201 were comparable. The normalcy rate of tetrofosmin images in the healthy subjects with low likelihood of coronary artery disease was 97%. Conclusions Tc-99m tetrofosmin is a new myocardial imaging agent with favorable imaging characteristics with results comparable to those of Tl-201.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [21] DYNAMIC MYOCARDIAL PERFUSION IMAGING WITH TC-99M TEBOROXIME IN PATIENTS - COMPARISONS WITH TL-201 AND ARTERIOGRAPHY
    KIM, AS
    AKERS, MS
    FABER, TL
    CORBETT, JR
    CIRCULATION, 1990, 82 (04) : 321 - 321
  • [22] TOMOGRAPHIC MYOCARDIAL PERFUSION IMAGING WITH TC-99M TEBOROXIME DURING ADENOSINE-INDUCED CORONARY HYPEREMIA - CORRELATION WITH TL-201 IMAGING
    ISKANDRIAN, AS
    HEO, J
    NGUYEN, T
    BEER, S
    CAVE, V
    CASSEL, D
    ISKANDRIAN, BB
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 307 - 312
  • [23] DEVELOPMENT OF A TC-99M MYOCARDIAL IMAGING AGENT TO REPLACE TL-201
    DEUTSCH, E
    GLAVAN, KA
    FERGUSON, DL
    LUKES, SJ
    NISHIYAMA, H
    SODD, VJ
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (06) : P56 - P56
  • [24] PARATHYROID IMAGING - A COMPARISON OF TL-201/TC-99M AND TC-99M SESTAMIBI/I-123
    BRASSEUR, F
    FOIDART, J
    MEURISSE, M
    VIVARIO, M
    RIGO, P
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1992, 19 (08): : 679 - 679
  • [25] Scapular hibernoma fortuitously discovered on myocardial perfusion imaging through Tc-99m tetrofosmin
    Oller, JD
    Gómez, JDT
    Kortazar, JF
    García, JDB
    Navarro, AA
    Albertino, RJV
    Díaz, JJA
    Llorente, JAA
    Andreu, MN
    Arcas, RF
    Medina, T
    Vázquez, RJM
    CLINICAL NUCLEAR MEDICINE, 2001, 26 (01) : 69 - 70
  • [26] Increased Tc-99m tetrofosmin uptake in a mediastinal tumor during myocardial perfusion imaging
    Vijayakumar, V
    Soloff, E
    Rahman, AM
    CLINICAL NUCLEAR MEDICINE, 2004, 29 (06) : 390 - 391
  • [27] Incidental Detection of Mediastinal Thymoma during Tc-99m Tetrofosmin Myocardial Perfusion Imaging
    Mohan, Parul
    Pathak, Vivek
    Joshi, Parmeshwar
    Baruah, B.
    Bal, S.
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2006, 21 (02): : 41 - 42
  • [28] REDUCED VARIABILITY OF INTERPRETATION AND IMPROVED IMAGE QUALITY WITH A TC-99M MYOCARDIAL PERFUSION AGENT - COMPARISON OF TL-201 AND TC-99M-LABELED TETROFOSMIN
    HENDEL, RC
    PARKER, MA
    WACKERS, FJT
    RIGO, P
    LAHIRI, A
    ZARET, BL
    JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (06) : 509 - 514
  • [29] Washout of Tc-99m Tetrofosmin on Delayed Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction after Coronary Revascularization
    Kim, D.
    Kim, C.
    Park, S.
    Jung, S.
    Kim, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S377 - S378
  • [30] A comparative evaluation of Tl-201 and Tc-99m sestamibi myocardial perfusion spect imaging in diabetic patients
    Özgür Ömür
    Zehra Özcan
    Murat Argon
    Ebru Tanı Acar
    The International Journal of Cardiovascular Imaging, 2008, 24 : 173 - 181