Non-invasive photo acoustic approach for human bone diagnosis

被引:6
|
作者
Thella, Ashok Kumar [2 ]
Rizkalla, James [1 ]
Helmy, Ahdy [1 ]
Suryadevara, Vinay Kumar [2 ]
Salama, Paul [2 ]
Rizkalla, Maher [2 ,3 ]
机构
[1] Indiana Univ, Sch Med, Bloomington, IN 47405 USA
[2] Indiana Univ Purdue Univ Indianapolis, Dept Elect & Comp Engn, Indianapolis, IN 46202 USA
[3] IUPUI, Integrated Nanosyst Dev Inst NDI, Indianapolis, IN USA
关键词
Photo acoustic tomography- PAT; PA; Diagnosis; Ortho; COMSOL;
D O I
10.1016/j.jor.2016.07.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The existing modalities of bone diagnosis including X-ray and ultrasound may cite drawback in some cases related to health issues and penetration depth, while the ultrasound modality may lack image quality. Photo acoustic approach however, provides light energy to the acoustic wave, enabling it to activate and respond according to the propagating media (which is type of bones in this case). At the same time, a differential temperature change may result in the bio heat response, resulting from the heat absorbed across the multiple materials under study. In this work, we have demonstrated the features of using photo acoustic modality in order to non-invasively diagnose the type of human bones based on their electrical, thermal, and acoustic properties that differentiate the output response of each type. COMSOL software was utilized to combine both acoustic equations and bio heat equations, in order to study both the thermal and acoustic responses through which the differential diagnosis can be obtained. In this study, we solved both the acoustic equation and bio heat equations for four types of bones, bone (cancellous), bone (cortical), bone marrow (red), and bone marrow (yellow). 1 MHz acoustic source frequency was chosen and 10(5) W/m(2) power source was used in the simulation. The simulation tested the dynamic response of the wave over a distance of 5 cm from each side for the source. Near 2.4 cm was detected from simulation from each side of the source with a temperature change of within 0.5 K for various types of bones, citing a promising technique for a practical model to detect the type of bones via the differential temperature as well as the acoustic was response via the multiple materials associated with the human bones (skin and blood). The simulation results suggest that the PA technique may be applied to non-invasive diagnosis for the different types of bones, including cancerous bones. A practical model for detecting both the temperature change via IR sensors, and acoustic wave signals may be detected via sensitive pressure transducer, which is reserved for future realization. (C) 2016 Prof. PK Surendran Memorial Education Foundation. Published by Elsevier, a division of RELX India, Pvt. Ltd. All rights reserved.
引用
收藏
页码:394 / 400
页数:7
相关论文
共 50 条
  • [21] A Machine Learning Approach for Non-Invasive Diagnosis of Metabolic Syndrome
    Datta, Suparno
    Schraplau, Anne
    da Cruz, Harry Freitas
    Sachs, Jan Philipp
    Mayer, Frank
    Boettinger, Erwin
    2019 IEEE 19TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2019, : 933 - 940
  • [22] THE COMBINED NON-INVASIVE DIAGNOSIS
    COLIN, C
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 1980, 9 (01): : 103 - 104
  • [23] Non-invasive malaria diagnosis
    Bradbury, Jane
    LANCET INFECTIOUS DISEASES, 2014, 14 (02): : 106 - 106
  • [24] A non-invasive optical approach to in vivo diagnosis of periodontal disease
    Sran, Kulginder
    Barrera, Jaclyn
    Baek, Jae Ho
    Ahm, Yehchan
    Zhang, Jun
    Kawakami-Wong, Hilari
    Chen, Zhongping
    Wilder-Smith, Petra
    LASERS IN SURGERY AND MEDICINE, 2008, : 81 - 81
  • [25] Non-invasive acoustic detection of wolves
    Suter, Stefan M.
    Giordano, Marta
    Nietlispach, Silvia
    Apollonio, Marco
    Passilongo, Daniela
    BIOACOUSTICS-THE INTERNATIONAL JOURNAL OF ANIMAL SOUND AND ITS RECORDING, 2017, 26 (03): : 237 - 248
  • [26] INVASIVE AND NON-INVASIVE METHODS FOR THE DIAGNOSIS OF TACHYCARDIAS
    ALDAKAR, M
    FONTAINE, G
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1988, 37 (05): : 265 - 276
  • [27] Invasive or non-invasive prenatal genetic diagnosis?
    Monni, Giovanni
    Zoppi, Maria Angelica
    Iuculano, Ambra
    Piras, Alessandra
    Arras, Maurizio
    JOURNAL OF PERINATAL MEDICINE, 2014, 42 (05) : 545 - 548
  • [28] Non-invasive Gearbox Fault Diagnosis Using Scattering Transform of Acoustic Emission
    Heydarzadeh, Mehrdad
    Nourani, Mehrdad
    Hansen, John
    Kia, Shahin Hedayati
    2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, : 371 - 375
  • [29] A metabolomics-based approach for non-invasive diagnosis of chromosomal anomalies
    Jacopo Troisi
    Laura Sarno
    Pasquale Martinelli
    Costantino Di Carlo
    Annamaria Landolfi
    Giovanni Scala
    Maurizio Rinaldi
    Pietro D’Alessandro
    Carla Ciccone
    Maurizio Guida
    Metabolomics, 2017, 13
  • [30] Electromagnetic simulation of non-invasive approach for the diagnosis of diabetic foot ulcers
    Borkar, Roshen
    Rizkalla, James
    Kwon, Youngmin
    Salama, Paul
    Rizkalla, Maher
    JOURNAL OF ORTHOPAEDICS, 2018, 15 (02) : 514 - 521