Fire effect on the tensile resistance of slabs steel reinforcement

被引:0
|
作者
Bespin, Angel [1 ]
Perez, Nerio [1 ]
Martinez, Edson [2 ]
Scola, Salvador [3 ]
机构
[1] Univ Carabobo, Fac Ingn, Escuela Ingn Civil, Valencia, Venezuela
[2] Univ Carabobo, Fac Ingn, Lab Mat & Ensayos, Valencia, Venezuela
[3] Inst Autonomo Municipal Cuerpo Bomberos Valencia, Valencia, Venezuela
来源
INGENIERIA UC | 2018年 / 25卷 / 01期
关键词
steel reinforcement; slab; fire exposition; tensile resistance;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper resume the results of the evaluation of the slabs steel reinforcement performance under the fire action, with the variation of the bar recoverment, studying the positive reinforcement steel tensile resistance. 9 slabs models were elaborated with 50cm x 70cm x 20cm dimensions, with 1, 3 y 5 centimeters of concrete recoverment; additionally 6 steel bars were tested, 3 of them were directly exposed to fire, and the rest were non fire exposed and were used like a model reference to compare the obtained tensile resistance. Every slabs were exposed to fire for 60 minutes, heated over a 400 degrees C temperature, after that the steel bars were extracted and tested. The results showed an excellent performance of the concrete like an isolating material, because all of the tested bars showed a similar stress-deformation diagram.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 50 条
  • [1] The effect of reinforcement ratios on composite slabs in fire
    Abu, Anthony K.
    Plank, Roger J.
    Burgess, Ian W.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2012, 165 (07) : 385 - 398
  • [2] Fire resistance of composite slabs with steel deck under natural fire
    Piloto, Paulo A. G.
    Balsa, Carlos
    Macedo Gomes, Felipe Macedo
    Matias, Bergson
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2021, 12 (04) : 522 - 540
  • [3] Effect of the load level on the resistance of composite slabs with steel decking under fire conditions
    Piloto, Paulo A. G.
    Balsa, Carlos
    Santos, Lucas M. C.
    Kimura, Erica F. A.
    JOURNAL OF FIRE SCIENCES, 2020, 38 (02) : 212 - 231
  • [4] Effect of steel-PET fiber reinforcement on the fire resistance of reactive powder concrete
    Bocian, Lubos
    Soukal, Frantisek
    Novotny, Radoslav
    Sokola, Patrik
    Markusik, David
    Bubenik, Jan
    Zach, Jiri
    Novak, Vitezslav
    MAGAZINE OF CONCRETE RESEARCH, 2025,
  • [6] Tensile membrane effects of concrete slabs in fire
    Dong, Y. -L.
    MAGAZINE OF CONCRETE RESEARCH, 2010, 62 (07) : 497 - 505
  • [7] FIRE RESISTANCE OF COMPOSITE SLABS
    HAMERLINCK, R
    TWILT, L
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1995, 33 (1-2) : 71 - 85
  • [8] Steel fibre reinforcement for suspended slabs
    Destree, X.
    Concrete (London), 2001, 35 (08):
  • [9] Tensile Membrane Action and the Performance of Composite Slabs in Fire
    Burgess, Ian
    Huang, Shan-Shan
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 755 - 763
  • [10] The influence of tensile membrane action in concrete slabs on the behaviour of composite steel-framed buildings in fire
    Huang, Zhaohui
    Burgess, Ian W.
    Plank, Roger J.
    Struct. Congr.: Struct. - Struct. Eng Odyssey, 1600,