Tensile Membrane Action and the Performance of Composite Slabs in Fire

被引:0
|
作者
Burgess, Ian [1 ]
Huang, Shan-Shan [1 ]
机构
[1] Univ Sheffield, Dept Civil & Struct Engn, Sheffield S1 3JD, S Yorkshire, England
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A common strategy for reducing passive fire protection on composite floor slabs is to specify protection only to primary and secondary beams on the column grid. While unprotected secondary steel beams lose much of their strength at high temperatures, large deflection of the central zone of the slab causes tensile membrane action (TMA), which enhances its load capacity compared with that of the small-deflection yield-line mechanism, and compensates for this loss of strength. Various simplified models of TMA, starting with the optimal small-deflection yield-line mechanism, have been developed as design methods for fire resistance, based mainly on research published in the 1960s. These methods have been published as design guides in the UK, the European Union and New Zealand, and have been implemented in public-domain design software. A critical appraisal of the original research, and the design methods developed from it, suggests that it is in need of re-development from the first principles of structural mechanics. Disparities exist in the logical approach, both in the treatment of enhancement of yield-line capacity with deflection, and in the limiting deflection corresponding to the "Integrity" limit of fire resistance. While the basic simplification of TMA is justifiable, the re-development needs to follow the sequence of behaviour as a composite slab with unprotected downstand beams is heated in fire. Initial studies of the yield-line behaviour of non-composite slabs and the enhancement of their capacity produced by TMA at finite deflections removed logical flaws from the existing treatments, and allowed the sequence of fracture of concrete and reinforcement to be tracked as deflections increase. However, since the compression zones of a concrete slab heat slowly in a fire and concrete tension cannot be considered in a design analysis, the effects of fire were not directly addressed. In this paper unprotected composite steel beams are included in a composite slab panel, and are heated as fire progresses. The initial yield-line mechanism differs from that of a non-composite slab, and varies with load intensity and beam temperature. This mechanism is fixed, but the slab deflects further as the beam temperatures rise. The formulation allows plasticity and fracture of the reinforcement, and the compressive strength of the concrete. Stresses around the yield lines can be monitored from negligible deflection to structural failure, and provides a rational way of predicting when integrity failure via a through-depth tensile crack will occur.
引用
收藏
页码:755 / 763
页数:9
相关论文
共 50 条
  • [1] Simple investigations of tensile membrane action in composite slabs in fire
    Allam, A
    Burgess, I
    Plank, R
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON STEEL STRUCTURES OF THE 2000'S, 2000, : 327 - 332
  • [2] The tensile membrane action of unrestrained composite slabs simulated under fire conditions
    Bailey, CG
    White, DS
    Moore, DB
    ENGINEERING STRUCTURES, 2000, 22 (12) : 1583 - 1595
  • [3] Tensile Membrane Action of Lightly-reinforced Rectangular Composite Slabs in Fire
    Burgess, Ian
    Sahin, Mesut
    STRUCTURES, 2018, 16 : 176 - 197
  • [4] Membrane Action of Composite Slabs in Fire - Experimental Investigation
    Mensinger, Martin
    Schaumann, Peter
    Stadler, Martin
    Sothmann, Joerg
    STAHLBAU, 2011, 80 (08) : 561 - 565
  • [5] Membrane action of composite slabs in fire - State of the art
    Mensinger, Martin
    Schaumann, Peter
    Stadler, Martin
    Sothmann, Joerg
    STAHLBAU, 2010, 79 (04) : 298 - 305
  • [6] Membrane action of composite slabs in fire - Numerical investigation
    Schaumann, Peter
    Mensinger, Martin
    Sothmann, Joerg
    Stadler, Martin
    STAHLBAU, 2011, 80 (12) : 911 - 915
  • [7] THE MECHANICS OF TENSILE MEMBRANE ACTION IN COMPOSITE SLABS AT HIGH TEMPERATURES
    Alskeif, A.
    Burgess, I. W.
    Huang, S. -S.
    APPLICATIONS OF STRUCTURAL FIRE ENGINEERING, 2017,
  • [8] Tensile membrane action in slabs and its application to the Cardington fire tests
    Wang, YC
    FIRE, STATIC AND DYNAMIC TESTS OF BUILDING STRUCTURES, 1997, : 55 - 67
  • [9] The influence of tensile membrane action in concrete slabs on the behaviour of composite steel-framed buildings in fire
    Huang, Zhaohui
    Burgess, Ian W.
    Plank, Roger J.
    Struct. Congr.: Struct. - Struct. Eng Odyssey, 1600,
  • [10] Numerical Modelling of Membrane Action of Composite Slabs in Fire Situation
    Vulcu, C.
    Gernay, Th.
    Zaharia, R.
    Franssen, J. M.
    STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, : 474 - +