CENTRAL AND PERIPHERAL CORNEAL THICKNESS IN FULL-TERM NEWBORNS BY ULTRASONIC PACHYMETRY

被引:1
|
作者
REMON, L
CRISTOBAL, JA
CASTILLO, J
PALOMAR, T
PALOMAR, A
PEREZ, J
机构
[1] HOSP CLIN UNIV,DEPT PEDIAT,ZARAGOZA,SPAIN
[2] HOSP CLIN UNIV,DEPT OPHTHALMOL,ZARAGOZA,SPAIN
关键词
CORNEAL THICKNESS; FULL-TERM NEWBORNS; ULTRASONIC PACHYMETRY;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To establish a standard of normality, the authors studied the central and peripheral (superior, inferior, nasal, and temporal) corneal thickness of 152 healthy, white race, full-term newborns (304 eyes) between 1 and 6 days old, using ultrasonic pachymetry. The mean central corneal thickness (CCT) was 585 +/- 52 mum (ranging from 446-706 mum). The mean peripheral corneal thickness (PCT), significantly thicker than CCT (P = 0.0001), was: superior (SCT) 696 +/- 55 mum, inferior (ICT) 744 +/- 62 mum, nasal (NCT) 742 +/- 58 mum, and temporal (TCT) 748 +/- 55 mum. The SCT was significantly thinner than the ICT, NCT, and TCT (P = 0.0001). Differences among ICT, NCT, and TCT were not statistically significant. The mean CCT of the 1-day-old group was 611 +/- 58 mum, this being thicker than those of the other age groups (P = 0.0001). The differences between male and female babies and between right and left eyes were not statistically significant. This is the first study on peripheral corneal thickness at the limbus in the four meridians in live newborns.
引用
下载
收藏
页码:3080 / 3083
页数:4
相关论文
共 50 条
  • [21] Comparison of central corneal thickness measurements obtained by ultrasonic pachymetry and the Orbscan Topography System
    Hsu, J
    Grossman, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S902 - S902
  • [22] Central corneal thickness and corneal diameter in preterm and term newborns and preterm neonates at term
    Sehrawat, Prateek
    Beri, Sarita
    Garg, Rajiv
    Datta, Vikram
    Shandil, Anurag
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1575 - 1578
  • [23] Comparison of Spectral Domain Optical Coherence Tomography and Ultrasonic Pachymetry for Assessment of Central Corneal Thickness
    Celebi, Ali Riza Cenk
    Mirza, G. Ertugrul
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (04): : 259 - 262
  • [24] Comparison of Central Corneal Thickness Measured by Tono-pachymetry and Ultrasound Pachymetry
    Park, Hye Yeon
    Shin, Hye-Young
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (07): : 904 - 909
  • [25] NECROTIZING ENTEROCOLITIS IN FULL-TERM NEWBORNS
    DEGAMARRA, E
    HELARDOT, P
    MORIETTE, G
    MURAT, I
    RELIER, JP
    BIOLOGY OF THE NEONATE, 1983, 44 (03): : 185 - 192
  • [26] Comparison of In Vivo Confocal Microscopy, Ultrasonic Pachymetry, and Scheimpflug Topography for Measuring Central Corneal Thickness
    MeenakshiSundaram, Soundaram
    Sufi, Aalia Rasool
    Prajna, N. Venkatesh
    Keenan, Jeremy D.
    JAMA OPHTHALMOLOGY, 2016, 134 (09) : 1057 - 1059
  • [27] INTRACRANIAL HEMORRHAGE IN FULL-TERM NEWBORNS
    CAROLLO, C
    ZORZI, C
    PIOVESAN, A
    SAIA, S
    BELLAVERE, D
    RIGOBELLO, L
    ACTA NEUROCHIRURGICA, 1984, 73 (1-2) : 122 - 123
  • [28] Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    Yaylali, V
    Kaufman, SC
    Thompson, HW
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09): : 1345 - 1350
  • [29] Accuracy of RTVue Optical Coherence Tomography, Pentacam, and Ultrasonic Pachymetry for the Measurement of Central Corneal Thickness
    Nam, Sang Min
    Im, Chan Young
    Lee, Hyung Keun
    Kim, Eung Kweon
    Kim, Tae-im
    Seo, Kyoung Yul
    OPHTHALMOLOGY, 2010, 117 (11) : 2096 - 2103
  • [30] A clinical comparison of central corneal thickness measurements with Optical Coherence Tomography versus ultrasonic pachymetry
    Bechmann, M
    Thiel, MJ
    Roesen, B
    Ullrich, S
    Ulbig, MW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S902 - S902