RELATION BETWEEN COPPER L X-RAY-FLUORESCENCE AND 2P X-RAY PHOTOELECTRON SPECTROSCOPIES

被引:33
|
作者
KAWAI, J
MAEDA, K
NAKAJIMA, K
GOHSHI, Y
机构
[1] INST PHYS & CHEM RES,WAKO,SAITAMA 35101,JAPAN
[2] UNIV TOKYO,DEPT IND CHEM,BUNKYO KU,TOKYO 113,JAPAN
来源
PHYSICAL REVIEW B | 1993年 / 48卷 / 12期
关键词
D O I
10.1103/PhysRevB.48.8560
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Lalpha1,2,beta1(L3,2-V) x-ray fluorescence spectra (XRF) and 2P1/2,3/2 x-ray photoelectron spectra (XPS) of various copper compounds are measured. It is found that the intensity of the high-energy hump of the Cu Lalpha XRF has a correlation with that of the high-binding-energy satellite (corresponding to the poorly screened 2p-1 final state) of the Cu2P3/2 XPS. While both the poorly screened peak in the 2P3/2 XPS and the high-energy hump in the Lalpha XRF are strong for ionic divalent copper compounds, both of them are very weak for covalent divalent copper compounds, and they exist for neither monovalent nor metallic copper compounds. It was believed that the high-energy hump of the Lalpha XRF originated from the electron transition between L3M4,5-M4,5(2) multiple-hole states, where the L3M4,5 double-hole state was created by the L1,2L3M4,5. Coster-Kronig transition prior to the x-ray transition. In this context, the Lalpha line shape, except for the high-energy hump, was believed to represent the Cu 3d electron density of states (DOS). Our results, however, exclude the possibility of the multiple vacancy satellite 2p(5)3d8 --> 3d7 for the origin of the high-energy hump of the Lalpha XRF of the divalent copper compounds. It is concluded that the major portion of the high-energy hump of the Lalpha XRF of the divalent copper compounds is due to the transition between the poorly screened states 2p(5)3d9 --> 3d8. Consequently, it is also concluded that the Lalpha line shape does not directly represent the 3d DOS but the high-energy hump hidden in the Lalpha main line represents the 3d DOS. We also conclude that the Lalpha main line originates from the charge-transfer effect.
引用
收藏
页码:8560 / 8566
页数:7
相关论文
共 50 条
  • [31] X-RAY-FLUORESCENCE ANALYSIS
    JENKINS, R
    ANALYTICAL CHEMISTRY, 1984, 56 (09) : 1099 - +
  • [32] Web-based methods for X-ray and photoelectron spectroscopies
    Devereaux, Thomas P.
    Moritz, Brian
    Jia, Chunjing
    Kas, Joshua J.
    Rehr, John. J.
    COMPUTATIONAL MATERIALS SCIENCE, 2021, 200
  • [33] ESTIMATION OF SPECTRAL DISTRIBUTION OF X-RAY TUBE FOR QUANTITATIVE X-RAY-FLUORESCENCE ANALYSIS
    MURATA, M
    SHIBAHARA, H
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 235 - 235
  • [34] LOW-POWERED TRANSMISSION X-RAY TUBE FOR EXCITING X-RAY-FLUORESCENCE
    BERDIKOV, VV
    GRIGOREV, OI
    IOKHIN, BS
    NIKOLAENKO, GM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (01) : 221 - 223
  • [35] THE INFLUENCE OF THE CHEMICAL ENVIRONMENT ON THE X-RAY RATE IN THE X-RAY-FLUORESCENCE OF ROCK SAMPLES
    WOOD, R
    QUARLES, CA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 : 635 - 637
  • [36] X-RAY-FLUORESCENCE ANALYSIS
    不详
    SOLID STATE TECHNOLOGY, 1981, 24 (01) : 22 - 23
  • [37] COMPUTERS AND X-RAY-FLUORESCENCE
    KARLSSON, A
    JKA-JERNKONTORETS ANNALER, 1984, 168 (06): : 42 - 42
  • [38] SPECTROMETRY OF THE PHOTON-BEAM FROM AN X-RAY TUBE BY X-RAY-FLUORESCENCE
    GONZALEZ, L
    MORAN, P
    DELGADO, V
    VANO, E
    LOPEZFRAGUAS, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (02): : 413 - 417
  • [39] FUNDAMENTAL PARAMETER METHOD FOR X-RAY-FLUORESCENCE ANALYSIS BY POLYCHROMATIC X-RAY SOURCE
    POZSGAI, I
    MAGYAR KEMIAI FOLYOIRAT, 1990, 96 (08): : 373 - 376
  • [40] X-RAY-FLUORESCENCE SPECTROMETRY
    POTTS, PJ
    WEBB, PC
    JOURNAL OF GEOCHEMICAL EXPLORATION, 1992, 44 (1-3) : 251 - 296