On-line calibration of positioning accuracy of CNC lathe using a double-frequency laser interferometer

被引:0
|
作者
Li, Xiaoqian [1 ]
Wang, Lihui [1 ]
Cai, Ningxu [1 ]
机构
[1] Natl Res Council Canada, Integrated Mfg Technol Inst, 800 Collip Circle, London, ON N6G 4X8, Canada
关键词
laser interferometer; machine tools; on-line calibration; positioning accuracy;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Positioning accuracy is an important factor affecting the performance of CNC machine tools. Targeting a high positioning accuracy, a fast and effective calibration technique is in an increasing demand from both machine tool users and manufacturers. This paper introduces an on-line calibration approach to dynamically evaluate the positioning accuracy of a CNC lathe through statistical estimation. A double-frequency laser interferometer is configured to measure the respective motions in the lathe's two perpendicular axes during the machining process, triggered by a cutting force dynamometer. Positioning accuracy calibration is realised by comparing the nominal positions from the CNC motion controller to their actual values measured by the laser interferometer system. Compared to that achieved at the machine idle state or the free running state using conventional techniques, this on-line calibration approach provides a more efficient way to get a real picture of the actual performance of a CNC machine tool under its working condition. It also gives a truthful reference to effectively compensate positioning errors of the CNC machine tool.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 28 条
  • [21] Laser-induced incandescence for soot particle size and volume fraction measurements using on-line extinction calibration
    B. Axelsson
    R. Collin
    P.E. Bengtsson
    Applied Physics B, 2001, 72 : 367 - 372
  • [22] Stabilization of synthetic wavelength using offset-frequency locking for the measurement accuracy improvement of the laser synthetic wavelength interferometer
    Chen, Benyong
    Wu, Kaiyue
    Yan, Liping
    Xie, Jiandong
    Zhang, Enzheng
    OPTICAL ENGINEERING, 2018, 57 (03)
  • [23] High speed and high accuracy inspection of in-tray laser IC marking using line scan CCD with a new calibration model
    Lin, Chern-Sheng
    Huang, Jui Tsung
    Wei, Tzu-Chi
    Yeh, Mau-Shiun
    Chen, Der-Chin
    OPTICS AND LASER TECHNOLOGY, 2011, 43 (01): : 218 - 225
  • [24] Super-heterodyne laser interferometer using femtosecond frequency comb for linear encoder calibration system - art. no. 66160G
    Kajima, Mariko
    Matsumoto, Hirokazu
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION V, PTS 1 AND 2, 2007, 6616 : G6160 - G6160
  • [25] MEASUREMENT OF BRILLOUIN LINE WIDTHS IN BENZENE DERIVATIVES USING A SUPER-MODE LASER AND FREQUENCY STABILIZED DIGITAL FABRY-PEROT INTERFEROMETER
    JACKSON, DA
    JONES, R
    PIKE, ER
    PHYSICS LETTERS A, 1968, A 28 (04) : 272 - &
  • [26] Biomonitoring of essential and toxic metals in single hair using on-line solution-based calibration in laser ablation inductively coupled plasma mass spectrometry
    Dressler, Valderi L.
    Pozebon, Dirce
    Mesko, Marcia Foster
    Matusch, Andreas
    Kumtabtim, Usarat
    Wu, B.
    Becker, J. Sabine
    TALANTA, 2010, 82 (05) : 1770 - 1777
  • [27] Impact of robot antenna calibration on dual-frequency smartphone-based high-accuracy positioning: a case study using the Huawei Mate20X
    Darugna, Francesco
    Wuebbena, Jannes B.
    Wuebbena, Gerhard
    Schmitz, Martin
    Schoen, Steffen
    Warneke, Andre
    GPS SOLUTIONS, 2020, 25 (01)
  • [28] Impact of robot antenna calibration on dual-frequency smartphone-based high-accuracy positioning: a case study using the Huawei Mate20X
    Francesco Darugna
    Jannes B. Wübbena
    Gerhard Wübbena
    Martin Schmitz
    Steffen Schön
    André Warneke
    GPS Solutions, 2021, 25