On-line calibration of positioning accuracy of CNC lathe using a double-frequency laser interferometer

被引:0
|
作者
Li, Xiaoqian [1 ]
Wang, Lihui [1 ]
Cai, Ningxu [1 ]
机构
[1] Natl Res Council Canada, Integrated Mfg Technol Inst, 800 Collip Circle, London, ON N6G 4X8, Canada
关键词
laser interferometer; machine tools; on-line calibration; positioning accuracy;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Positioning accuracy is an important factor affecting the performance of CNC machine tools. Targeting a high positioning accuracy, a fast and effective calibration technique is in an increasing demand from both machine tool users and manufacturers. This paper introduces an on-line calibration approach to dynamically evaluate the positioning accuracy of a CNC lathe through statistical estimation. A double-frequency laser interferometer is configured to measure the respective motions in the lathe's two perpendicular axes during the machining process, triggered by a cutting force dynamometer. Positioning accuracy calibration is realised by comparing the nominal positions from the CNC motion controller to their actual values measured by the laser interferometer system. Compared to that achieved at the machine idle state or the free running state using conventional techniques, this on-line calibration approach provides a more efficient way to get a real picture of the actual performance of a CNC machine tool under its working condition. It also gives a truthful reference to effectively compensate positioning errors of the CNC machine tool.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 28 条
  • [1] Double-frequency laser interferometer with unambiguous phase reading for large tokamaks
    Petrov, AA
    Petrov, VG
    Shevchenko, VF
    PLASMA DEVICES AND OPERATIONS, 1999, 7 (02): : 103 - 110
  • [2] Double-frequency laser interferometer with unambiguous phase reading for large tokamaks
    142092, TRINITI, Troitsk, Russia
    Plasma Devices Oper, 2 (103-110):
  • [3] Dynamic calibration of the positioning accuracy of machine tools and coordinate measuring machines using a laser interferometer
    Castro, HFF
    Burdekin, M
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2003, 43 (09): : 947 - 954
  • [4] Improved accuracy of on-line tire profile measurement using a novel on-line calibration
    Khalili, K.
    Nazemsadat, S. M.
    PROCEEDINGS OF THE SEVENTH IASTED INTERNATIONAL CONFERENCE ON VISUALIZATION, IMAGING, AND IMAGE PROCESSING, 2007, : 59 - +
  • [5] Meteorological testing accuracy of a double frequency laser interferometer for length measurement
    Liu, Yongdong
    Fei, Yetai
    Zhongguo Jiguang/Chinese Journal of Lasers, 1998, 25 (04): : 299 - 302
  • [6] Semiconductor laser's on-line coherence calibration and testing of frequency stability
    Zakharov, Yu. N.
    Popov, A. Yu.
    Tyurin, A. V.
    8TH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2008, 7008
  • [7] Angular Multiplexing Storage in Azo-polymerLiquid Crystal Films Using Shearing Interferometer of Double-frequency Grating
    ZHANG Jiangying MING Hai WANG Pei WU Yunxia XIE JianpingZHANG Qijin LIU JianDepartment of Physics
    ChineseJournalofLasers, 2002, (02) : 43 - 46
  • [8] Accurate on-line depth calibration with a laser interferometer during SIMS profiling on the Cameca IMS WF instrument
    Merkulov, A
    Merkulova, O
    de Chambost, E
    Schuhmacher, M
    APPLIED SURFACE SCIENCE, 2004, 231 : 954 - 958
  • [9] THE MEASURING ACCURACY OF A LASER SPECKLE INTERFEROMETER USING A DOUBLE-APERTURE METHOD
    IWATSUKI, N
    HAYASHI, I
    KITAGAWA, S
    INTERNATIONAL JOURNAL OF THE JAPAN SOCIETY FOR PRECISION ENGINEERING, 1994, 28 (02): : 156 - 163
  • [10] Accuracy improvement of a white-light spectral interferometer using a line-by-line spectral calibration method
    Guo, Tong
    Zhao, Guanhua
    Tang, Dawei
    Weng, Qianwen
    Gao, Feng
    Jiang, Xiangqian
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2020, 8 (02):