MR-IMAGING OF THE LIVER - BREATH-HOLD T1-WEIGHTED MP-GRE COMPARED WITH CONVENTIONAL T2-WEIGHTED SE IMAGING - LESION DETECTION, LOCALIZATION, AND CHARACTERIZATION

被引:29
|
作者
DELANGE, EE [1 ]
MUGLER, JP [1 ]
BOSWORTH, JE [1 ]
DEANGELIS, GA [1 ]
GAY, SB [1 ]
HURT, NS [1 ]
BERR, SS [1 ]
ROSENBLATT, JM [1 ]
MERICKEL, LW [1 ]
HARRIS, EK [1 ]
机构
[1] UNIV VIRGINIA,HLTH SCI CTR,DIV BIOSTAT,CHARLOTTESVILLE,VA 22908
关键词
LIVER; MR; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; RAPID IMAGING; TECHNOLOGY; TISSUE CHARACTERIZATION;
D O I
10.1148/radiology.190.3.8115619
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare breath-hold T1-weighted magnetization-prep ared gradient-echo (MP-GRE) imaging with conventional T2-weighted spin-echo (SE) imaging in evaluation of focal liver disease. MATERIALS AND METHODS: Images of 68 patients evaluated for focal liver disease were reviewed. Five sets of images were analyzed: axial, sagittal, and coronal breath-hold T1-weighted MP-GRE images, axial T2-weighted SE images, and a compilation of axial, sagittal, and coronal (three-plane) T1-weighted ME-GEE images. Lesion signal intensity (SI) and signal difference-to-noise (SD/N) ratios were calculated. RESULTS: Lesions were detected, localized, and characterized more accurately (P <.05-.001) and with greater confidence on three-plane T1-weighted ME-GEE images than on almost all single-plane images. Mean SI ratios of nonsolid and solid lesions on MP-GRE and SE images were significantly different at all lesion sizes; mean SD/N ratio was significantly different only for large lesions. CONCLUSION: Lesion detection, localization, and characterization can be accurately and confidently performed with three-plane T1-weighted MP-GRE breath-hold imaging, potentially obviating conventional T2-weighted SE imaging.
引用
收藏
页码:727 / 736
页数:10
相关论文
共 50 条
  • [21] FAST SE T2-WEIGHTED MR IMAGING OF THE ABDOMEN
    CATASCA, JC
    MIROWITZ, SA
    RADIOLOGY, 1992, 185 : 234 - 234
  • [22] Comparison of T2-weighted imaging, diffusion-weighted imaging and contrast-enhanced T1-weighted MR imaging for evaluating perianal fistulas
    Baik, Jiyeon
    Kim, Seung Ho
    Lee, Yedaun
    Yoon, Jung-Hee
    CLINICAL IMAGING, 2017, 44 : 16 - 21
  • [23] SOLITARY HEPATIC METASTASIS - COMPARISON OF DYNAMIC CONTRAST-ENHANCED CT AND MR-IMAGING WITH FAT-SUPPRESSED T2-WEIGHTED, BREATH-HOLD T1-WEIGHTED FLASH, AND DYNAMIC GADOLINIUM-ENHANCED FLASH SEQUENCES
    SEMELKA, RC
    SHOENUT, JP
    ASCHER, S
    KROEKER, MA
    GREENBERG, HM
    YAFFE, CS
    MICFLIKIER, AB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 319 - 323
  • [24] MR-IMAGING OF CERVICAL-CARCINOMA - COMPARISON BETWEEN T2-WEIGHTED, DYNAMIC, AND POSTCONTRAST T1-WEIGHTED IMAGES WITH HISTOPATHOLOGIC CORRELATION
    TSUDA, K
    MURAKAMI, T
    KURACHI, H
    OGAWA, H
    MIYAKE, A
    NAKAMURA, H
    RADIOLOGY, 1995, 197 : 475 - 475
  • [25] Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions
    Tseng, GY
    Thng, CH
    Wong, EH
    Tan, AGS
    Suman, P
    Quek, ST
    Ho, JTS
    Khoo, JKB
    Ooi, LLPJ
    Chow, PKH
    Chung, YFA
    Teh, CSC
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2003, 32 (04) : 450 - 454
  • [26] T2-WEIGHTED BREATH-HOLD MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A 3-DIMENSIONAL STEADY-STATE FREE PRECESSION SEQUENCE IN 87 PATIENTS
    TAUPITZ, M
    SPEIDEL, A
    HAMM, B
    DEIMLING, M
    REICHEL, M
    BOCK, A
    WOLF, KJ
    RADIOLOGY, 1995, 194 (02) : 439 - 446
  • [27] Comparison of in-phase and opposed-phase GRE and conventional SE MR pulse sequences in T1-weighted imaging of liver lesions
    Martin, J
    Sentis, M
    Puig, J
    Rue, M
    Falco, J
    Donoso, L
    Zidan, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (06) : 890 - 897
  • [28] MR-IMAGING OF HEAD AND NECK TUMORS - COMPARISON OF T1-WEIGHTED CONTRAST-ENHANCED FAT-SUPPRESSED IMAGES WITH CONVENTIONAL T2-WEIGHTED AND FAST SPIN-ECHO T2-WEIGHTED IMAGES
    ROSS, MR
    SCHOMER, DF
    CHAPPELL, P
    ENZMANN, DR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 173 - 178
  • [29] Liver lesion conspicuity: T2-weighted breath-hold fast spin-echo MR imaging before and after gadolinium enhancement-initial experience
    Jeong, YY
    Mitchell, DG
    Holland, GA
    RADIOLOGY, 2001, 219 (02) : 455 - 460
  • [30] MR-IMAGING EVALUATION OF KNEE COLLATERAL LIGAMENTS AND RELATED INJURIES - COMPARISON OF T1-WEIGHTED, T2-WEIGHTED, AND FAT-SATURATED T2-WEIGHTED SEQUENCES - CORRELATION WITH CLINICAL FINDINGS
    MIROWITZ, SA
    SHU, HH
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 725 - 732