CRITICAL HEAT-FLUX IN HORIZONTAL ANNULAR CHANNELS WITH VARIABLE ECCENTRICITY

被引:2
|
作者
BALINO, JL
CONVERTI, J
机构
[1] Comision Nacional de Energia Atomica Centro Atomico Bariloche - Div. Termohidraulica, 8400 Bariloche, Río Negro
关键词
D O I
10.1016/0735-1933(91)90078-I
中图分类号
O414.1 [热力学];
学科分类号
摘要
Measurements of critical heat flux (CHF) were performed for a horizontal annular channel (diameters 11.2 and 54 mm, approx. 1m heated length) in which the eccentricity in the vertical direction of the inner heater could be varied. Measurements for low mass fluxes (up to 1600 kg/m2/s) using freon-12 at a pressure of approx. 10.3 bar and saturation inlet conditions, show a strong influence of eccentricity on CHF; this influence is discussed on a basis of the flow pattern under which CHF occurs.