Operation of a Two-Phase Reverse Loop Thermosyphon

被引:3
|
作者
Tsai, Meng-Chang [1 ]
Kang, Shung-Wen [2 ]
Li, Heng-Yi [1 ]
Tsai, Wen-Fa [1 ]
机构
[1] Inst Nucl Energy Res, Taoyuan 325, Taiwan
[2] Tamkang Univ Tamsui, Dept Mech & Elect Mech Engn, Fujisawa, Kanagawa 251, Japan
来源
关键词
Reverse-loop; Thermosyphon; Heat Transfer Downward; Cyclic Operation;
D O I
10.6180/jase.2015.18.3.06
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A prototype two-phase reverse-loop thermosyphon (RLT) was fabricated to transport thermal energy downwards to a thermal storage tank. The effect the filling ratio exerted on the thermal performance of the RTL was investigated by conducting experiments that were performed by a range between 47% and 63%. The prototype device comprised an evaporator, a condenser, a reservoir (preheater), and pipes connecting each of the components. The heat transport height was 1500 mm from the evaporator to the bottom of the condenser. Methanol with a concentration of 95% was used as the working fluid. The temperature distribution, temperature difference between the evaporator and condenser, and thermal resistance of the thermosyphon were measured. In addition, a cyclic case, in which the power in coils was alternately switched on and off according to a square wave function was studied. The results indicated that the maximal thermal performance of the RLT occurred when the filling ratio was 60% and the input power was 660W.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 50 条
  • [31] Experimental investigation on startup performances of a separator assisted two-phase loop thermosyphon
    Zhu, Lin
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [32] TRANSIENT CHARACTERISTICS OF A TWO-PHASE THERMOSYPHON LOOP FOR COOLING TELECOMMUNICATION OUTDOOR CABINETS
    Louahlia-Gualous, H.
    Mecheri, B.
    Nortershauser, D.
    Le Masson, S.
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010 , VOL 3: COMBUSTION, CONDUCTION, ELECTRONIC COOLING, EVAPORATION,TWO-PHASE FLOW, 2010, : 467 - 472
  • [33] Simulation on the thermal performance of two-phase thermosyphon loop with large height difference
    Zhang, Penglei
    Yang, Xiaorui
    Rong, Xingyue
    Zhang, Dalin
    APPLIED THERMAL ENGINEERING, 2019, 163
  • [34] Design of a two-phase loop thermosyphon for telecommunications system (II)—Analysis and Simulation—
    S. H. Rhi
    Won Tae Kim
    Kwang Soo Kim
    Yung Lee
    KSME International Journal, 1999, 13 (7) : 586 - 586
  • [35] Two-phase thermosyphon loop with different working fluids used in data centers
    Tong, Zhen
    Han, Zekun
    Fang, Chunxue
    Wen, Xinran
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 214
  • [36] A performance evaluation index for two-phase thermosyphon loop used in HVAC systems
    Zhang, Penglei
    Shi, Wenxing
    Li, Xianting
    Wang, Baolong
    Zhang, Guohui
    APPLIED THERMAL ENGINEERING, 2018, 131 : 825 - 836
  • [37] A Research of Closed Loop Two-Phase Thermosyphon Based on Lattice Boltzmann Method
    Zheng, Wen-Han
    Hong, Fang-Jun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (02): : 462 - 467
  • [38] Application of a two-phase thermosyphon loop calculation method to a cold neutron source
    de Haan, Victor-O
    Knudsen, Kenneth D.
    CRYOGENICS, 2019, 97 : 55 - 62
  • [39] Design of a two-phase loop thermosyphon for telecommunications system (I)Experiments and visualization
    Won Tae Kim
    Kyu Sub Song
    Young Lee
    KSME International Journal, 1998, 12 : 926 - 941
  • [40] Reduced order model of a two-phase loop thermosyphon by modal identification method
    Bodjona, Serge
    Girault, Manuel
    Videcoq, Etienne
    Bertin, Yves
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 123 : 637 - 654