A FAST TIME-TO-DIGITAL CONVERTER FOR POSITION-SENSITIVE RADIATION DETECTORS WITH DELAY-LINE READOUTS

被引:8
|
作者
HARDER, JA
机构
关键词
D O I
10.1016/S0168-9002(98)90020-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:500 / 510
页数:11
相关论文
共 50 条
  • [1] DUAL TIME TO DIGITAL CONVERTER FOR DELAY-LINE READOUT OF POSITION-SENSITIVE GAS-FILLED DETECTORS
    BERRY, A
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05): : 1222 - 1228
  • [2] Vernier parallel delay-line based time-to-digital converter
    Chi-Tung Ko
    Kong-Pang Pun
    Andreas Gothenberg
    [J]. Analog Integrated Circuits and Signal Processing, 2012, 71 : 151 - 153
  • [3] Vernier parallel delay-line based time-to-digital converter
    Ko, Chi-Tung
    Pun, Kong-Pang
    Gothenberg, Andreas
    [J]. ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2012, 71 (01) : 151 - 153
  • [4] Design of a delay-line position-sensitive detector with improved performance
    Da Costa, G
    Vurpillot, F
    Bostel, A
    Bouet, M
    Deconihout, B
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (01):
  • [5] Neutron measurements on the MK 200N-1 type two-dimensional delay-line position-sensitive detector with the new OTDCV1.11 time-to-digital converter
    Cser, L
    Gabriel, A
    Kocsis, M
    Messing, G
    Rosta, L
    Török, G
    [J]. PHYSICA B, 2000, 276 : 216 - 217
  • [6] HIGH-COUNT-RATE OPERATION OF A TFTR POSITION-SENSITIVE X-RAY-DETECTOR WITH DELAY-LINE READOUTS
    HSUAN, H
    BITTER, M
    VONGOELER, S
    HARDER, JA
    HILL, KW
    LEMUNYAN, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2771 - 2773
  • [7] A POSITION-SENSITIVE MICROCHANNELPLATE DETECTOR USING A DELAY-LINE READOUT ANODE
    KELLER, H
    KLINGELHOFER, G
    KANKELEIT, E
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 258 (02): : 221 - 224
  • [8] A POSITION-SENSITIVE PARTICLE DETECTOR WITH A MEANDER-TYPE DELAY-LINE
    LIU, B
    LIESEN, D
    ENDERS, W
    SCHULZE, R
    WARCZAK, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 240 (01): : 139 - 144
  • [9] LOW-DEAD-TIME DELAY-LINE READOUT FOR POSITION-SENSITIVE PROPORTIONAL-COUNTERS
    ANDERSON, AN
    BARRETT, RJ
    WADLINGER, EA
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1974, 119 (02): : 365 - 366
  • [10] Analysis of fluorescence effects in a position-sensitive gas detector using a time-stamp time-to-digital converter
    Niebuhr, M
    Gabriel, A
    Koch, MHJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (03): : 309 - 317