Transcranial Doppler ultrasound, bispectral index, and electroencephalographic monitoring of entropy during pediatric total intravenous anesthesia

被引:2
|
作者
Calvo Vecino, J. M. [1 ]
Abad Gurumeta, A. [2 ]
Garrido Reche, E. [1 ]
Chao Novo, K. [1 ]
Orts Castro, A. [1 ]
Tomas Lachos, J. [1 ]
机构
[1] Hosp Infanta Leonor, Complejo Hosp Vallecas, Serv Anestesiol & Reanimac, Madrid, Spain
[2] Hosp Infanta Sofia, Madrid, Spain
来源
关键词
Monitoring; depth of hypnosis; Doppler ultrasound; Cerebral blood flow; Electroencephalography; anesthetic depth (entropy); Bispectral index; processing; Propofol; Pediatrics;
D O I
10.1016/S0034-9356(10)70298-X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND AND OBJECTIVE: Transcranial Doppler ultrasound is a noninvasive technique for monitoring the velocity of blood flow in the main intracranial arteries, particularly those in the circle of Willis. Our aim was to assess whether changes in cerebral arterial blood flow in anesthetized pediatric patients detected by pulsed Doppler ultrasound correlate with changes in the bispectral (BIS) index and electroencephalographic state and response entropy (ES and ER, respectively). MATERIAL AND METHODS: Prospective, blinded observational study of 36 pediatric patients (age range, 5 to 11 years) under total intravenous anesthesia for minor surgical procedures. Propofol and fentanyl were used for induction; propofol and remifentanil in continuous perfusion and a single dose of cisatracurium were used for maintenance. In all patients we monitored hemodynamic and respiratory patterns, gases, temperature, and hypnosis (BIS, ES and ER) as well as cerebral blood flow estimated by pulsed Doppler ultrasound in the middle cerebral artery. Raw data were subjected to statistical smoothing. The resistance index, pulsatility index, mean velocity, and estimated baseline cerebral blood flow were calculated from the Doppler sonogram. We then studied the correlations between the Doppler-derived values and BIS, ES, ER, fraction of end-tidal carbon dioxide, and temperature. The variables were entered into logistic regression. RESULTS: The pattern at induction indicated high resistance (low mean velocities and high pulsatility indexes) until the lowest BIS and ES values of 31 and 29, respectively, were reached. During maintenance, the Doppler sonogram pattern was slower (normalization of the pulsatility index, the resistance index, and mean velocity). Changes in flow and absolute entropy and BIS values were statistically correlated (Pearson's r values >= 0.91); there was 95.6% agreement between Doppler values and BIS and agreement between BIS and ES values of 35-45. On awakening, flow velocities approached baseline values when BIS and ES rose to between 90 and 98. The estimated cerebral blood flow underwent fluctuations coinciding with an approximately concomitant increase or decrease in BIS (r > 0.95); the response of BIS was slightly delayed by no more than a minute but there was no corresponding response of entropy measurements. CONCLUSIONS: We report Doppler ultrasound patterns during anesthesia with propofol. Systems for monitoring hypnosis could be considered indirect measurements of cerebral blood flow; BIS measurements are more sensitive to flow change. Transcranial Doppler ultrasound facilitates the observation of changes in blood flow that occur at different levels of hypnosis during anesthesia.
引用
收藏
页码:621 / 629
页数:9
相关论文
共 50 条
  • [1] Transcranial Doppler ultrasound, bispectral index, and electroencephalographic monitoring of entropy during sevoflurane anesthesia in children
    Abad Gurumeta, A.
    Calvo Vecino, J. M.
    Abad Motos, A.
    Oliden Gutierrez, L.
    Garcia Alvarez, R.
    Nieto Moreno, A.
    [J]. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2010, 57 (10): : 630 - 638
  • [2] Do we need bispectral index monitoring during total intravenous anesthesia for lumbar discectomies?
    Akcali, Didem Tuba
    Ozkose, Zerrin
    Yardim, Sahin
    [J]. TURKISH NEUROSURGERY, 2008, 18 (02) : 125 - 133
  • [3] Cerebral hypoperfusion during pediatric cardiac surgery detected by combined bispectral index monitoring and transcranial doppler ultrasonography
    Toyama, Satoshi
    Sakai, Hirokazu
    Ito, Sukeyuki
    Suzuki, Yasuyuki
    Kondo, Yoichi
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2011, 23 (06) : 498 - 501
  • [4] The relationship between bispectral index and electroencephalographic parameters during isoflurane anesthesia
    Morimoto, Y
    Hagihira, S
    Koizumi, Y
    Ishida, K
    Matsumoto, M
    Sakabe, T
    [J]. ANESTHESIA AND ANALGESIA, 2004, 98 (05): : 1336 - 1340
  • [5] Effects of etomidate on bispectral index scale and spectral entropy during induction of anesthesia by means of the raw electroencephalographic and electromyographic characteristics
    Kim, Hyun-Mok
    Shin, Sang-Wook
    Yoon, Ji-Young
    Lee, Hyeon-Jeong
    Kim, Kyung-Hoon
    Baik, Seong-Wan
    [J]. KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 62 (03) : 230 - 233
  • [6] Comparative Evaluation of a New Depth of Anesthesia Index in ConView® System and the Bispectral Index during Total Intravenous Anesthesia: A Multicenter Clinical Trial
    Fu, Yang
    Xu, Tao
    Xie, Keliang
    Wei, Wei
    Gao, Ping
    Nie, Huang
    Deng, Xiaoming
    Wang, Guolin
    Tian, Ming
    Yan, Min
    Dong, Hailong
    Yue, Yun
    [J]. BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [7] Comparative study of implicit memory during bispectral index guided total intravenous anesthesia versus sevoflurane inhalation anesthesia
    Elbadawy, Ahmed M.
    Khidr, Ahmed M.
    Saleh, Alia Adel
    [J]. EGYPTIAN JOURNAL OF ANAESTHESIA, 2015, 31 (01) : 9 - 13
  • [8] Patient Factors Affecting Bispectral Index During Total Intravenous Anesthesia With Target-Controlled Infusion
    Schnider, Thomas W.
    Minto, Charles F.
    Egan, Talmage D.
    Filipovic, Miodrag
    [J]. ANESTHESIA AND ANALGESIA, 2020, 131 (03): : E160 - E160
  • [9] TOTAL INTRAVENOUS ANESTHESIA USING EITHER BISPECTRAL INDEX MONITORING OR TARGET CONTROLLED INFUSION IN MAJOR ABDOMINAL SURGERY
    El-Hadi, S.
    Omran, M. M.
    [J]. ANESTHESIA AND ANALGESIA, 2012, 114
  • [10] Intravenous Anesthesia With Bispectral Index Monitoring vs Inhalational Anesthesia for Rhytidoplasty A Randomized Clinical Trial
    Jones, Kristin A.
    LaFerriere, Keith A.
    [J]. JAMA FACIAL PLASTIC SURGERY, 2015, 17 (04) : 239 - 244