The relationship between bispectral index and electroencephalographic parameters during isoflurane anesthesia

被引:88
|
作者
Morimoto, Y [1 ]
Hagihira, S
Koizumi, Y
Ishida, K
Matsumoto, M
Sakabe, T
机构
[1] Yamaguchi Univ, Sch Med, Dept Anesthesiol Resuscitol, Yamaguchi 7558505, Japan
[2] Osaka Prefectural Habikino Hosp, Dept Anesthesiol, Osaka, Japan
来源
ANESTHESIA AND ANALGESIA | 2004年 / 98卷 / 05期
关键词
D O I
10.1213/01.ANE.0000105867.17108.B6
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Bispectral index (BIS) integrates various electroencephalographic (EEG) parameters into a single variable. However, the exact algorithm used to synthesize the parameters to BIS values is not known. The relationship between BIS and EEG parameters was evaluated during nitrous oxide/isoflurane anesthesia. Twenty patients scheduled for elective ophthalmic surgery were enrolled in the study. After EEG recording with a BIS monitor (A-1050) was begun, general anesthesia was induced and maintained with 0.5%-2% isoflurane and 66% nitrous oxide. Using software we developed, we continuously recorded BIS, spectral edge frequency 95% (SEF95), and EEG parameters such as relative beta ratio (BetaRatio), relative synchrony of fast and slow wave (SynchFastSlow), and burst suppression ratio. BetaRatio was linearly correlated with BIS (r = 0.90; P < 0.01; n = 253) at BIS more than 60. At a BIS range of 30 to 80, SynchFastSlow (r = 0.60; P < 0.01; n = 3314) and SEF95 (r = 0.75; P < 0.01; n = 3339) were linearly correlated with BIS. The correlation between BIS and SEF95 was significantly better than the correlation between BIS and SynchFastSlow (P < 0.01). At BIS less than 30, the burst suppression ratio was inversely linearly correlated with BIS (r = 0.76; P < 0.01; n = 65). At BIS less than 80, burst-compensated SEF95 was linearly correlated with BIS (r = 0.78; P < 0.01; n = 3404). In the range of BIS from 60 to 100, BIS can be calculated from BetaRatio. At surgical levels of anesthesia, BIS and SynchFastSlow (a parameter derived from bispectral analysis) or burst-compensated SEF95 (derived from power spectral analysis) are well correlated. However, our results show that SynchFastSlow has no advantage over SEF95 in calculation of BIS.
引用
收藏
页码:1336 / 1340
页数:5
相关论文
共 50 条
  • [1] Pregnancy reduces the bispectral index during isoflurane anesthesia.
    Gin, T
    Chan, MTV
    ANESTHESIOLOGY, 1997, 87 (03) : A305 - A305
  • [2] Effect of morphine on the bispectral index during isoflurane anesthesia in dogs
    Henao-Guerrero, Piedad N.
    McMurphy, Rose
    KuKanich, Butch
    Hodgson, Dave S.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2009, 36 (02) : 133 - 143
  • [3] Comparison of Bispectral Index and Vital Parameters in Rabbits Receiving Propofol or Isoflurane Anesthesia
    Saritas, Tuba Berra
    Saritas, Zulfikar Kadir
    Korkmaz, Musa
    Sivaci, Remziye Gul
    ACTA SCIENTIAE VETERINARIAE, 2013, 41
  • [4] PREDICTION OF MOVEMENT USING BISPECTRAL ELECTROENCEPHALOGRAPHIC ANALYSIS DURING PROPOFOL ALFENTANIL OR ISOFLURANE ALFENTANIL ANESTHESIA
    VERNON, JM
    LANG, E
    SEBEL, PS
    MANBERG, P
    ANESTHESIA AND ANALGESIA, 1995, 80 (04): : 780 - 785
  • [5] Hemodynamic and bispectral index responses to tracheal intubation during isoflurane or sevoflurane anesthesia
    Masayasu Nakayama
    Noriaki Kanaya
    Mitsutaka Edanaga
    Akiyoshi Namiki
    Journal of Anesthesia, 2003, 17 (4) : 223 - 226
  • [6] Effect of medetomidine administration on bispectral index measurements in dogs during anesthesia with isoflurane
    Greene, SA
    Tranquilli, WJ
    Benson, J
    Grimm, KA
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2003, 64 (03) : 316 - 320
  • [7] Recovery of bispectral index: Isoflurane vs desflurane anesthesia
    Guignard, B
    Menigaux, C
    Ben Boukhatem, A
    Chauvin, M
    ANESTHESIOLOGY, 1998, 89 (3A) : U180 - U180
  • [8] Relationship Between Propofol Target Concentrations, Bispectral Index, and Patient Covariates During Anesthesia
    Schnider, Thomas W.
    Minto, Charles F.
    Egan, Talmage D.
    Filipovic, Miodrag
    ANESTHESIA AND ANALGESIA, 2021, 132 (03): : 735 - 742
  • [9] Narcotrend® and Bispectral Index® monitor are superior to classic electroencephalographic parameters for the assessment of anesthetic states during propofol-remifentanil anesthesia
    Schmidt, GN
    Bischoff, P
    Standl, T
    Jensen, K
    Voigt, M
    Esch, JSA
    ANESTHESIOLOGY, 2003, 99 (05) : 1072 - 1077
  • [10] Relationship between bispectral index and auditory evoked potential index for propofol and midazolam during induction of general anesthesia
    Hashimoto, Atsushi
    Fujiwara, Yoshihiro
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 116 - 116