Measurements of peripheral dose for multileaf collimator based linear accelerator

被引:2
|
作者
Balasubramanian, R. [1 ]
Sellakumar, P. [1 ]
Bilimagga, Ramesh S. [1 ]
Supe, Sanjay S. [2 ]
Sankar, B. N. [3 ]
机构
[1] Bangalore Inst Oncol, 44-45-2,II CROSS,Off Lalbagh Double Rd, Bangalore 560027, Karnataka, India
[2] Kidwai Mem Inst Oncol, Bangalore, Karnataka, India
[3] Anna Univ, Dept Phys, Madras, Tamil Nadu, India
关键词
multileaf collimator; megavolt beams; peripheral dose; radiation dosimetry;
D O I
10.1016/S1507-1367(06)71073-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background In radiation therapy, peripheral dose (PD), or the dose outside the geometrical boundaries of the radiation field, is of clinical importance when anatomical structures such as foetus in pregnant women, gonads, and lenses of the eye, with low dose tolerances are involved. Even a small percentage of the total treatment dose might cause injury in such cases. The sources of peripheral dose are leakage from the treatment unit, scatter from the secondary collimators and beam modifiers such as wedges and blocks, and internal scatter originating in the patient Aim To determine the peripheral dose (PD) for multileaf collimator (MLC) based linear accelerator in water equivalent slab phantom for open and wedged fields. Materials/Methods PD measurements were carried out for 6 and 15MV photons using a 0.4cc parallel plate chamber in the slab phantom. Measurements were performed for different field sizes at different depths (D-max, 5cm and 10cm) and up to a maximum distance of 30cm beyond the field edges. PD was measured using wedge filters also. PD was further computed using a three-dimensional treatment planning system (3D TPS). Results For 6MV photon beams, the maximum PD for open beams at 5cm distance from the field edge was 3.42% and the minimum PD at 20cm distance was 0.11%. For 15MV, the maximum PD for open beam at 5cm distance was 3.07% and the minimum PD was 0.14%. For wedge filters, the maximum PD measured at 5cm distance for 6 and 15MV photons were 5.56% (60 degrees Wedge) and 5.03% (45 degrees wedge). The TPS PD values showed minimal variation from the measured values. Conclusions The PD due to MLC and beam modifiers would definitely be helpful to assess the doses received by the relevant critical structures outside the treatment field.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 50 条
  • [31] A rotor-based multileaf collimator for beam shaping
    Majernik, N.
    Andonian, G.
    Parrack, A.
    Rosenzweig, J. B.
    Doran, S.
    Wisniewski, E.
    Power, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [32] Measurement of back-scattered radiation from micro multileaf collimator into the beam monitor chamber from a dual energy linear accelerator
    Muralidhar, K. R.
    Murthy, P. Narayana
    Sresty, N. V. N. M.
    Dixit, Pramod Kumar
    Kumar, Rajneesh
    Raju, A. K.
    JOURNAL OF MEDICAL PHYSICS, 2007, 32 (02) : 65 - 67
  • [33] Generation of wedge-shaped dose distributions through dynamic multileaf collimator dose delivery
    Zhu, Jingeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (03): : 37 - 45
  • [34] Dose deviations caused by positional inaccuracy of multileaf collimator in intensity modulated radiotherapy
    Wang, H. C.
    Chui, C. S.
    Tsai, H. Y.
    Chen, C. H.
    Tsai, L. F.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 925 - 928
  • [35] Effects of MLC setting on dose distributions and on multileaf collimator parameters for treatments with IMRT
    Chauvet, I
    Petitfils, A
    Brunet, Y
    Lembrez, R
    Lehobey, C
    Kristner, JY
    Zefkili, S
    Gaboriaud, G
    Mazal, A
    Rosenwald, JC
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S36 - S37
  • [36] THE DISPLACEMENT OF THE ISOCENTRE OF AN ELEKTA SYNERGY ACCELERATOR CAUSED BY THE APEX ADD-ON DYNAMIC MULTILEAF COLLIMATOR
    Zimmermann, S. J.
    Riis, H. L.
    Hjelm-Hansen, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S537 - S537
  • [37] Neutron and Photon Dose Levels Produced by Field Shaping Blocks and a Multileaf Collimator
    McGinley, P. H.
    Persons, T. M.
    Radiation Protection Management, 12 (01):
  • [38] Evaluation of dose calculation algorithm of the peacock system for multileaf intensity modulation collimator
    Wu, A
    Johnson, M
    Chen, ASJ
    Kalnicki, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (05): : 1225 - 1231
  • [39] Analytical Modeling of the Parameters of a Multileaf Collimator for Monte Carlo Dose Simulations in Radiotherapy
    Martins, J.
    Neppl, S.
    Alhazmi, A.
    Fleckenstein, J.
    Dedes, G.
    Reiner, M.
    Belka, C.
    Parodi, K.
    Veloza, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E451 - E451
  • [40] The peripheral dose outside the applicator in electron beams of an Elekta linear accelerator
    Abbas Haghparast
    Fatemeh Amiri
    Mehran Yarahmadi
    Mohammad Rezaei
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 647 - 655