Measurements of peripheral dose for multileaf collimator based linear accelerator

被引:2
|
作者
Balasubramanian, R. [1 ]
Sellakumar, P. [1 ]
Bilimagga, Ramesh S. [1 ]
Supe, Sanjay S. [2 ]
Sankar, B. N. [3 ]
机构
[1] Bangalore Inst Oncol, 44-45-2,II CROSS,Off Lalbagh Double Rd, Bangalore 560027, Karnataka, India
[2] Kidwai Mem Inst Oncol, Bangalore, Karnataka, India
[3] Anna Univ, Dept Phys, Madras, Tamil Nadu, India
关键词
multileaf collimator; megavolt beams; peripheral dose; radiation dosimetry;
D O I
10.1016/S1507-1367(06)71073-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background In radiation therapy, peripheral dose (PD), or the dose outside the geometrical boundaries of the radiation field, is of clinical importance when anatomical structures such as foetus in pregnant women, gonads, and lenses of the eye, with low dose tolerances are involved. Even a small percentage of the total treatment dose might cause injury in such cases. The sources of peripheral dose are leakage from the treatment unit, scatter from the secondary collimators and beam modifiers such as wedges and blocks, and internal scatter originating in the patient Aim To determine the peripheral dose (PD) for multileaf collimator (MLC) based linear accelerator in water equivalent slab phantom for open and wedged fields. Materials/Methods PD measurements were carried out for 6 and 15MV photons using a 0.4cc parallel plate chamber in the slab phantom. Measurements were performed for different field sizes at different depths (D-max, 5cm and 10cm) and up to a maximum distance of 30cm beyond the field edges. PD was measured using wedge filters also. PD was further computed using a three-dimensional treatment planning system (3D TPS). Results For 6MV photon beams, the maximum PD for open beams at 5cm distance from the field edge was 3.42% and the minimum PD at 20cm distance was 0.11%. For 15MV, the maximum PD for open beam at 5cm distance was 3.07% and the minimum PD was 0.14%. For wedge filters, the maximum PD measured at 5cm distance for 6 and 15MV photons were 5.56% (60 degrees Wedge) and 5.03% (45 degrees wedge). The TPS PD values showed minimal variation from the measured values. Conclusions The PD due to MLC and beam modifiers would definitely be helpful to assess the doses received by the relevant critical structures outside the treatment field.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 50 条
  • [1] Peripheral dose measurements for 6 and 18 MV photon beams on a linear accelerator with multileaf collimator
    Mazonakis, Michalis
    Zacharopoulou, Fotini
    Varveris, Haralambos
    Damilakis, John
    MEDICAL PHYSICS, 2008, 35 (10) : 4396 - 4403
  • [2] A comparative study of the peripheral doses from a linear accelerator with a multileaf collimator system
    Acun, Hediye
    Zubaroglu, Ali
    Kemikler, Gonul
    Bozkurt, Ahmet
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (03) : 299 - 306
  • [3] Peripheral dose from a linear accelerator equipped with multileaf collimation
    Stern, RL
    MEDICAL PHYSICS, 1999, 26 (04) : 559 - 563
  • [4] Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator
    Klueter, Sebastian
    Sroka-Perez, Gabriele
    Schubert, Kai
    Debus, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02): : N29 - N37
  • [5] Relative dosimetry evaluation for small multileaf collimator fields on a TrueBeam linear accelerator
    Younes, T.
    Beilla, S.
    Simon, L.
    Fares, G.
    Vieillevigne, L.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S429 - S429
  • [6] Impact of the high-definition multileaf collimator on linear accelerator-based intracranial stereotactic radiosurgery
    Tanyi, J. A.
    Kato, C. M.
    Chen, Y.
    Chen, Z.
    Fuss, M.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1003): : 629 - 638
  • [7] Megavoltage image-based dynamic multileaf collimator tracking of a NiTi stent in porcine lungs on a linear accelerator
    Poulsen, Per R.
    Carl, Jesper
    Nielsen, Jane
    Nielsen, Martin S.
    Thomsen, Jakob B.
    Jensen, Henrik K.
    Kjærgaard, Benedict
    Zepernick, Peter R.
    Worm, Esben
    Fledelius, Walther
    Cho, Byungchul
    Sawant, Amit
    Ruan, Dan
    Keall, Paul J.
    International Journal of Radiation Oncology Biology Physics, 2012, 82 (02):
  • [8] Anomaly detection in time and spectral domain for the driving motors of multileaf collimator of a medical linear accelerator
    Kim, Kwang Hyeon
    Lee, Suk
    Sohn, Moon-Jun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2023, 82 (01) : 107 - 115
  • [9] Anomaly detection in time and spectral domain for the driving motors of multileaf collimator of a medical linear accelerator
    Kwang Hyeon Kim
    Suk Lee
    Moon-Jun Sohn
    Journal of the Korean Physical Society, 2023, 82 : 107 - 115
  • [10] Characterizing a Geant4 Monte Carlo model of a multileaf collimator for a TrueBeam™ linear accelerator
    Kandlakunta, Praneeth
    Momin, Shadab
    Sloop, Austin
    Zhang, Tiezhi
    Khan, Rao
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 1 - 12